Q48SK12033NRFH Delta Electronics, Q48SK12033NRFH Datasheet - Page 10

CONV DC/DC 33A 48V/IN 12V/O NEG

Q48SK12033NRFH

Manufacturer Part Number
Q48SK12033NRFH
Description
CONV DC/DC 33A 48V/IN 12V/O NEG
Manufacturer
Delta Electronics
Series
DELPHIr
Type
Isolated with Remote On/Off and UVLOr
Datasheet

Specifications of Q48SK12033NRFH

Output
12V
Number Of Outputs
1
Power (watts)
400W
Mounting Type
Through Hole
Voltage - Input
48V
Package / Case
6-DIP Module, 1/4 Brick
1st Output
12 VDC @ 33A
Size / Dimension
2.28" L x 1.45" W x 0.50" H (57.9mm x 36.8mm x 12.7mm)
Power (watts) - Rated
396W
Operating Temperature
-40°C ~ 108°C
Efficiency
95.5%
Approvals
cUL, UL
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Other names
941-1013
DS_Q48SK12033_07012010
THERMAL CURVES
(WITHOUT HEAT SPREADER)
* The allowed maximum hot spot temperature is defined at 117
Figure 19: Output current vs. ambient temperature and air
velocity @Vin=48V(Transverse Orientation, without heat
spreader)
33
30
27
24
21
18
15
12
Figure 18: Temperature measurement location
9
6
3
0
25
Output Current(A)
Convection
Natural
30
100LFM
35
200LFM
Q48SK12033(Standard) Output Current vs. Ambient Temperature and Air Velocity
40
300LFM
400LFM
45
@Vin = 48V (Transverse Orientation)
50
55
60
65
70
600LFM
75
Ambient Temperature (℃)
500LFM
80
85
THERMAL CURVES
(WITH HEAT SPREADER)
* The allowed maximum hot spot temperature is defined at 108
Figure 21: Output current vs. ambient temperature and air velocity
@Vin=48V(Transverse Orientation, with heat spreader)
Figure 20: Temperature measurement location
33
30
27
24
21
18
15
12
9
6
3
0
25
Output Current(A)
Convection
Natural
30
100LFM
35
200LFM
Q48SK12033(Standard) Output Current vs. Ambient Temperature and Air Velocity
40
300LFM
@Vin = 48V (Transverse Orientation, With Heatspreader)
45
400LFM
50
500LFM
55
60
65
70
75
Ambient Temperature (℃)
600LFM
80
85
10