VHB50W-Q24-S15 CUI Inc, VHB50W-Q24-S15 Datasheet

CONVERTER DC/DC 9-36V INPUT 50W

VHB50W-Q24-S15

Manufacturer Part Number
VHB50W-Q24-S15
Description
CONVERTER DC/DC 9-36V INPUT 50W
Manufacturer
CUI Inc
Series
V-Infinity VHB50Wr
Type
Isolatedr
Datasheet

Specifications of VHB50W-Q24-S15

Output
15V
Number Of Outputs
1
Power (watts)
50W
Mounting Type
Through Hole
Voltage - Input
9 ~ 36V
Package / Case
9-DIP Module
1st Output
15 VDC @ 3.33A
Size / Dimension
2.40" L x 2.28" W x 0.50" H (61mm x 57.9mm x 12.7mm)
Power (watts) - Rated
50W
Operating Temperature
-40°C ~ 100°C
Efficiency
83%
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Other names
102-1568
PART NUMBER: VHB50W
MODEL
VHB50W-Q24-S3R3
VHB50W-Q24-S5
VHB50W-Q24-S12
VHB50W-Q24-S15
VHB50W-Q24-S24
VHB50W-Q24-S28
VHB50W-Q24-S48
VHB50W-Q48-S3R3
VHB50W-Q48-S5
VHB50W-Q48-S12
VHB50W-Q48-S15
VHB50W-Q48-S24
VHB50W-Q48-S28
VHB50W-Q48-S48
notes:
INPUT
parameter
input voltage range
under voltage lockout
remote on/off control
input filter
notes:
*V-Infinity reserves the right to make changes to its products or to discontinue any product or service without notice, and to advise customers to verify the most up-to-
date product information before placing orders. V-Infinity assumes no liability or responsibility for customer’s applications using V-Infinity products other than repair
or replacing (at V-I’s option) V-Infinity products not meeting V-I’s published specifications. Nothing will be covered outside of standard product warranty.
description
The VHB50W series of DC-DC converters
are designed for high reliability
applications, featuring over-temperature
protection, over-current protection. The
wide 4:1 input range (9-36V or 18-75V) is
very useful to stabilize an input source
like batteries in various discharging and
charging conditions. Additionally, high
efficiency, fast response, tight
regulations, remote sense and remote
On/Off control make these converters
very useful in many applications.
20050 SW 112
4
1. see output derating (page 4)
2. input currents are measured at nominal input voltage
3. efficiency is measured at nominal line, full load
4. add suffix “N” to the model number for negative logic on/off control
th
Ave. Tualatin, Oregon 97062
conditions/description
24 Vin power up
24 Vin power down
48 Vin power up
48 Vin power down
section 15 in the application notes
PI type
nominal
(V dc)
24
24
24
24
24
24
24
48
48
48
48
48
48
48
input voltage
features
·25-50W isolated output
·Efficiency to 84%
·300 kHz switching frequency
·regulated output
·continuous short circuit
·industry standard half-brick size
·remote on/off
·over-temperature protection
·over-current protection
protection
18.0~75.0
18.0~75.0
18.0~75.0
18.0~75.0
18.0~75.0
18.0~75.0
18.0~75.0
9.0~36.0
9.0~36.0
9.0~36.0
9.0~36.0
9.0~36.0
9.0~36.0
9.0~36.0
(V dc)
range
phone
phone 503.612.2300 fax
DESCRIPTION: half-brick dc-dc converter
voltage
output
(V dc)
3.3
3.3
12
15
24
28
48
12
15
24
28
48
5
5
min
18
9
current
output
4.16
3.33
2.08
1.78
1.04
4.16
3.33
2.08
1.78
1.04
(A)
10
10
10
10
nom
8.8
24
48
17
16
fax 503.612.2382
8
1
no load
max
(mA)
36
75
50
50
50
50
50
50
50
50
50
50
50
50
50
50
input current
2
full load
1785
2637
2537
2538
2537
2537
2537
1302
1267
1265
1264
1264
1253
(mA)
905
rev.
page
date
page
date
units
V dc
V dc
V dc
V dc
V dc
V dc
2
06/2009
1 of 11
efficiency
typ.
(%)
77
81
83
83
83
83
83
78
82
84
84
84
84
83
3

Related parts for VHB50W-Q24-S15

VHB50W-Q24-S15 Summary of contents

Page 1

... Additionally, high efficiency, fast response, tight regulations, remote sense and remote On/Off control make these converters very useful in many applications. MODEL VHB50W-Q24-S3R3 VHB50W-Q24-S5 VHB50W-Q24-S12 VHB50W-Q24-S15 VHB50W-Q24-S24 VHB50W-Q24-S28 VHB50W-Q24-S48 VHB50W-Q48-S3R3 VHB50W-Q48-S5 VHB50W-Q48-S12 VHB50W-Q48-S15 VHB50W-Q48-S24 VHB50W-Q48-S28 ...

Page 2

... PART NUMBER: VHB50W OUTPUT parameter conditions/description voltage accuracy transient response 25% step load change external trim adj. range ripple & noise (20MHz BW) 3.3V, 5V 12V& 15V 24V 28V 48V temperature coefficient short circuit protection continuous 5 line regulation 6 load regulation over voltage protection trip range nom. ...

Page 3

... PART NUMBER: VHB50W MECHANICAL DRAWING th 20050 SW 112 Ave. Tualatin, Oregon 97062 DESCRIPTION: half-brick dc-dc converter phone phone 503.612.2300 fax fax 503.612.2382 page date 06/2009 ...

Page 4

... APPLICATION NOTES 1. OUTPUT DE-RATING The operating case temperature range for VHB50W is -40 ~ +100°C. When operating the VHB50W series, proper derating or cooling is needed. The maximum case temperature under any operating condition should not exceed 100°C. Power Dissipated vs Ambient Temperature and Air Flo w Ambient Temperature ,Ta(Deg ...

Page 5

... The fuse rating will depend on the input range and should allow for the maximum current at the lowest input volt- age, as shown in this equation: Ipeak = 150%*Pout/(η η *Vmin). In the previous example of VHB50W-Q24-S5, the peak input current at 9V was calculated to be 10. fuse may be suitable for this application. Make sure the fuse voltage rating is higher than the maximum input voltage. ...

Page 6

... R load R trim- nom ) (KΩ) R trim-down o, nom is the Where: R o,nom nominal output voltage. V Table 2. For example, to trim-up the output voltage of 5.0V is calculated module (VHB50W-Q48-S5 4.6V, R trim-up = 11.2 (KΩ) Ω Ω 7.2 3.3 4.636 7.191 Table 2 6.977 173.7 13.3 phone phone 503.612.2300 fax 10KΩ ...

Page 7

... PART NUMBER: VHB50W 8. OUTPUT OCP AND SHORT-CIRCUIT PROTECTION Output overload and short circuit conditional will cause the output voltage to decline or shutdown altogether. is not over 100°C, the output recovers automatically when the short or OCP conditions are removed. In the case of slight overloading, the output voltage may not shut down, but the converter may build up heat over time, causing over-temperature shutdown ...

Page 8

... PART NUMBER: VHB50W 12. OUTPUT SERIES CONNECTIONS Two or more converters can be connected in series to obtain a higher output voltage. To prevent output reverse biasing each other in case of a short, add a Schottky diode on each output in reverse polarity, as shown in the diagram. In the event of a short, the con- verters will forward-bias the diodes and the output reversal will be limited to one diode drop (about 0 ...

Page 9

... PART NUMBER: VHB50W 15. INPUT FILTERING AND EMI INTERFERENCE The VHB50W converters have input capacitors that control input current ripple and the associated EMI interference. However, it has not been tested to a formal standard for conducted emissions. Additional filtering may be needed to ensure compliance to an EMI standard ...

Page 10

... PART NUMBER: VHB50W FIGURE 10.2B. EMI FILTER FOR VHB50W (CLASS B) L1 +Vin C1 -Vin Note: Model No. C1 VHB50W-Q24-S28 100uF/50V KY VHB50W-Q48-S28 100uF/100V KY 100uF/100V 1000pF/2KV NC L1 FUSE TVS C1 EMI to meet class A C1 VHB50W-Q24-S48 NC VHB50W-Q48-S48 NC EMI to meet class B C1 10uF/50V VHB50W-Q24-S48 X7R,2220 Ceramic 47uF/100V VHB50W-Q48-S48 KMF note: The recommended components are a starting point but not guaranteed for meeting these EMI requirements ...

Page 11

... PART NUMBER: VHB50W 16. OUTPUT FILTERING The converter has built-in capacitors at the output to control ripple and noise. If desired, additional output capacitance can be introduced at the input to the powered equipment. Recommended starting point: one 10μF tantalum and one 1μF ceramic capacitor in parallel at the output. ...