RPP40-483.3S Recom Power Inc, RPP40-483.3S Datasheet - Page 3

CONV DC/DC 40W SNGL 3.3V OUT

RPP40-483.3S

Manufacturer Part Number
RPP40-483.3S
Description
CONV DC/DC 40W SNGL 3.3V OUT
Manufacturer
Recom Power Inc
Series
Powerline RPP40r
Type
Isolatedr
Datasheet

Specifications of RPP40-483.3S

Output
3.3V
Number Of Outputs
1
Power (watts)
40W
Mounting Type
Through Hole
Voltage - Input
36 ~ 75V
Package / Case
6-DIP Module
1st Output
3.3 VDC @ 12A
Size / Dimension
2.00" L x 1.20" W x 0.46" H (50.8mm x 30.5mm x 11.7mm)
Power (watts) - Rated
40W
Operating Temperature
-45°C ~ 84°C
Efficiency
90.2%
Product
Isolated
Output Power
40 W
Input Voltage Range
36 V to 75 V
Input Voltage (nominal)
36 V to 75 V
Output Voltage (channel 1)
3.3 V
Isolation Voltage
3 KV
Package / Case Size
2 in x 1.2 in
Output Voltage
3.3 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
 Details
Other names
30900447
945-1303

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
RPP40-483.3S
Manufacturer:
Recom Power Inc
Quantity:
135
1. Typical values at nominal input voltage and no load/full load.
2. Typical values at nominal input voltage and full load.
3. Typical values at nominal input voltage and full load in vertical orientation and with Eurocard-sized PCB ground planes to assist in heat dissipation.
4. The ON/OFF control function can be positive or negative logic. The pin voltage is referenced to negative input.
5. Requires an external 100µF/100V low ESR capacitor to meet EN61000-4-4 and EN61000-4-5
6. Case l: 50% Stress, Temperature at 50°C (Ground Benign).
7. To ensure a good all-round electrical contact, the baseplate is pressed firmly into place within the aluminium housing.The hydraulic press can leave
www.recom-international.com
POWERLINE+
DC/DC-Converter
Safety Standards
Thermal Cycling
Vibration
Conducted Emissions
Radiated Emissions
ESD
Radiated Immunity
Fast Transient
Surge
Conducted Immunity
MTBF calculated according to BELLCORE TR-NWT-000332
Notes :
Recommended PCB Layout
Specifications
Input Fuse is recommended, but optional. Recommended fuse rating = double maximum input current, time delay type.
Input Capacitor, C1, is required to meet EN61000 Surge and Fast Transient, otherwise it is not required for normal operation.
Output Capacitors C2/C3 are recommended, but not required for normal operation. Typical capacitor values are 1µF/100V MLCC
To ensure optimum thermal performance, use large areas of copper on the PCB to assist with heat dissipation and mount the converter vertically.
For horizontal orientation, reduce the maximum temperatures by 10°C.
tooling marks and deformations to both the housing and baseplate. The case is anodised aluminium, so there will be natural variations in the case
colour and the aluminium is not scratch resistant. Any resultant marks, scratches and colour varations are cosmetic only and do not affect the
operation or performance of the converters.
(5)
Positive logic ON/OFF is standard, no suffix (Ex. RPP50-2405S)
Negative logic ON/OFF option has suffix /N (Ex. RPP50-2405S/N)
(5)
(typical at nominal input and 25°C unless otherwise noted)
Single Output
(6)
REV:0/2009
EN55022
EN55022
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
Dual Output
RPP40/50
Series
10-55Hz, 12G, 30 Min. along X, Y and Z
complies with MIL-STD-810F
UL-60950-1 Pending
1989 x 10
Perf. Criteria B
Perf. Criteria B
Perf. Criteria B
Perf. Criteria A
Perf. Criteria A
Class B
Class B
PP-19
3
hours

Related parts for RPP40-483.3S