REC3.5-1224SRW/R8/A/CTRL/X1-R Recom Power Inc, REC3.5-1224SRW/R8/A/CTRL/X1-R Datasheet

CONV DC/DC 2A 6.5-18VIN 3.0-5.5V

REC3.5-1224SRW/R8/A/CTRL/X1-R

Manufacturer Part Number
REC3.5-1224SRW/R8/A/CTRL/X1-R
Description
CONV DC/DC 2A 6.5-18VIN 3.0-5.5V
Manufacturer
Recom Power Inc
Series
Econoline REC3.5/Rr
Type
Isolated with Remote On/Off and UVLOr
Datasheet

Specifications of REC3.5-1224SRW/R8/A/CTRL/X1-R

Output
24V
Number Of Outputs
1
Power (watts)
3.5W
Mounting Type
Through Hole
Voltage - Input
9 ~ 18V
Package / Case
24-DIP Module (7 Leads)
1st Output
24 VDC @ 145mA
Size / Dimension
1.26" L x 0.80" W x 0.40" H (32mm x 20.3mm x 10.2mm)
Power (watts) - Rated
3.5W
Operating Temperature
-40°C ~ 85°C
Efficiency
83%
Approvals
CB, CSA, EN, UL
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Other names
11001558
www.recom-international.com
The REC3.5 series uses a reinforced isolation transformer to offer exceptionally high isolation of 8kVDC (4kVAC/1 minute)
or 10kVDC (5kVAC/1minute) making it suitable for HT monitoring circuits, mains power meters, IGBT isolated power
supplies and other sophisticated industrial and medical applications. The isolation capacitance of only 20pF makes them
also suitable for low leakage applications. The isolation transformer is recognised by CSA as reinforced isolated with a
minimum internal clearance of 2.4mm and a minimum internal creepage clearance of 4.6mm. The REC3.5 is available in
two industry-standard pinouts (=
and an optional undervoltage lockout function is also available (=
for short periods of time to cope with applications with large capacitive loads or high start up currents.
Description
Selection Guide
Features
Regulated
Converters
* add suffix "/A" or "/C" for pinning options,
* add suffix “/CTRL” for control pin option (A Pinning only)
* add suffix "/X1" for Undervoltage Lockout
* add suffix -R for Tape and Reel packaging
Part
Number
DIP24
REC3.5-xx05SRW/R*
REC3.5-xx09SRW/R*
REC3.5-xx12SRW/R*
REC3.5-xx15SRW/R*
REC3.5-xx24SRW/R*
REC3.5-xx05DRW/R*
REC3.5-xx09DRW/R*
REC3.5-xx12DRW/R*
REC3.5-xx15DRW/R*
R* = R8 or R10 for 8kVDC or 10kVDC isolation.
Note 1: Maximum capacitive load is defined as the capacitive load that will allow start up in under
1 second without damage to the converter.
Ordering Examples:
REC3.5-0512DRW/R8/A/CTRL= 5V Vin, ±12V Vout, 8kVDC isolation, pinout “A”,control pin
REC3.5-4805SRW/R10/A = 48V Vin, 5V Vout, 10kVDC isolation, pinout “A”
REC3.5-1212DRW/R8/C/X1 = 12V Vin, ±12V Vout, 8kVDC isolation, pinout “C”,UVL
REC3.5-0505SRW/R10/A/CTRL/X1 = 5V Vin, 5V Vout, 10kVDC isolation, pinout “A”,control pin, UVL
see next page for details.
9 - 18, 18 - 36, 36 - 75
9 - 18, 18 - 36, 36 - 75
9 - 18, 18 - 36, 36 - 75
9 - 18, 18 - 36, 36 - 75
9 - 18, 18 - 36, 36 - 75
9 - 18, 18 - 36, 36 - 75
9 - 18, 18 - 36, 36 - 75
9 - 18, 18 - 36, 36 - 75
9 - 18, 18 - 36, 36 - 75
"/A"
or
"/C"
Voltage
4.5 - 9
4.5 - 9
4.5 - 9
4.5 - 9
4.5 - 9
4.5 - 9
4.5 - 9
4.5 - 9
4.5 - 9
(VDC)
Input
). Remote on/off control is possible with the /CTRL option (A pinning only)
8kVDC
Industry Standard DIP24 Package
3.5W Regulated Output
Continuous Short Circuit Protection
Wide Input 2:1
Medical Approved
EN, CSA and CB Certificates
2 Pinout Options
Control Pin Option
Efficiency to 86%
&
10kVDC Reinforced Isolation
Voltage
Output
"/X1"
(VDC)
±12
±15
±5
±9
12
15
24
5
9
). The converters can deliver 140% rated power
REV:2/2010
Current
Output
±350
±194
±145
±117
(mA)
700
388
290
233
145
(REC3.5-S_DRW/R8(R10)
xx = 4.5-9Vin = 05
xx = 9-18Vin = 12
xx = 18-36Vin = 24
xx = 36-75Vin = 48
80, 81, 82
81, 82, 83
82, 83, 84
84, 85, 86
83, 84, 85
80, 81, 82 ±2200µF
81, 82, 83 ±1600µF
81, 82, 83 ±1000µF
82, 83, 84 ±1000µF
Efficiency
2:1 Input
(%)
77
80
82
83
82
77
80
82
80
Capacitive
4700µF
3300µF
2200µF
2200µF
1000µF
Load
Max
(1)
Derating-Graph
(Ambient Temperature)
3.5 Watt DIP24
Reinforced
Single
Output
C22.2-No. 60950 Certified
C22.2-601.1 Certified
UL-60601.1 Certified
2002/95/EC
REC3.5/R
RoHS
ECONOLINE
DC/DC-Converter
with 3 year Warranty
6/6
Refer to Application Notes
&
Dual
E-314885
E-103

Related parts for REC3.5-1224SRW/R8/A/CTRL/X1-R

REC3.5-1224SRW/R8/A/CTRL/X1-R Summary of contents

Page 1

... The isolation capacitance of only 20pF makes them also suitable for low leakage applications. The isolation transformer is recognised by CSA as reinforced isolated with a minimum internal clearance of 2.4mm and a minimum internal creepage clearance of 4.6mm. The REC3.5 is available in "/A" ...

Page 2

... Ref: CA/11158/CSA Medical Safety Report: 2202478 Medical Safety E314885 General Safety Report: 2219431 Recognised as Reinforced Isolation REV: 2/2010 REC3.5-S_DRW /R* Series ±0.3% max. ±0.6% max. 3.5V typ. (±20%) 7V typ. (±20%) 15V typ. (±10%) 32V typ. (±10%) 150mVp-p max. 150kHz min. / 500kHz max. ...

Page 3

... ECONOLINE DC/DC-Converter Typical Characteristics - Continued REC3.5-xx05SRW/R* REC3.5-xx05DRW/R* REC3.5-xx12SRW/R* REC3.5-xx24SRW/R* REC3.5-xx12DRW/R* www.recom-international.com REC3.5-S_DRW /R* Series Efficiency vs Load REV:2/2010 Efficiency vs Vin E-105 ...

Page 4

... Package Style and Pinning (mm) DIP 24 , Wide Input 2:1 “A” Pinning /R8 & /R10 CTRL Option ON = Open or 0V< V ctrl <1.2V OFF = 2.2V< V ctrl <12V “C” Pinning /R8 & /R10 E-106 REC3.5-S_DRW /R* Series Recommended Footprint Details W Recommended Footprint Details REV: 1/2010 Pin Connections Pin # Single ...

Related keywords