RP40-240515TG/HC Recom Power Inc, RP40-240515TG/HC Datasheet - Page 3

CONV DC/DC 40W 18-36VIN 5 +/-15V

RP40-240515TG/HC

Manufacturer Part Number
RP40-240515TG/HC
Description
CONV DC/DC 40W 18-36VIN 5 +/-15V
Manufacturer
Recom Power Inc
Series
Powerline RP40-Gr
Type
Isolated with Remote On/Off and UVLOr
Datasheet

Specifications of RP40-240515TG/HC

Output
5V, ±15V
Number Of Outputs
3
Power (watts)
40W
Mounting Type
Through Hole
Voltage - Input
18 ~ 36V
Package / Case
9-DIP Module
1st Output
5 VDC @ 6A
2nd Output
15 VDC @ 300mA
3rd Output
-15 VDC @ 300mA
Size / Dimension
2.00" L x 2.00" W x 0.40" H (50.8mm x 50.8mm x 10.2mm)
Power (watts) - Rated
40W
Operating Temperature
-40°C ~ 85°C
Efficiency
87%
Approvals
cUL, UL
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
4th Output
-
Lead Free Status / Rohs Status
Supplier Unconfirmed
Other names
30002061
www.recom-international.com
POWERLINE
DC/DC-Converter
Specifications
Ripple and Noise (20MHz bandwith)
(Measured with a 1004pF/50V MLCC)
(see Note 12)
Temperature Coefficient
Transient Response (25% load step change)
Over Voltage Protection
Zener diode clamp (only single)
Over Load Protection (% of full load at nominal Vin)
Undervoltage Lockout
Short Circuit Protection
Efficiency
Isolation Voltage (rated for one minute)
Isolation Resistance
Isolation Capacitance
Operating Frequency (see Note 14)
Approved to Safety Standards
Operating Temperature Range
Maximum Case Temperature
Storage Temperature Range
Thermal Impedance (see Note 8)
Thermal Shock
Vibration
Relative Humidity
Case Material
Base Material
Potting Material
Conducted Emissions (see Note 16)
Radiated Emissions
ESD
Radiated Immunity
Fast Transient
Surge
Conducted Immunity
Weight
Packing Quantity
Dimensions
MTBF (see Note 2)
(typical at nominal input and 25°C unless otherwise noted)
REV:1/2010
Single 3.3, 5V
Single 12, 15V
Dual 12V
Dual 15V
RP40-xxxxxxTG
3.3V
5V
12V
15V
Single,Triple
Dual
Natural convection
Heat Sink with 20LFM
Heat Sink with 500LFM
EN55022
EN55022
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
Refer to App Notes for tube dimensions
RP40-S_D_TG
Series
10-55Hz, 10G, 30 Min. along X, Y and Z
Non-conductive black plastic FR4
-40°C to +85°C(with derating)
see „Selection Guide“ table
Hiccup, automatic recovery
50.8 x 50.8 x 10.2mm
See Application Notes
Nickel plated copper
UL 1950, EN60950
-55°C to +125°C
1398 x 10
±0.02%/°C max.
Epoxy (UL94-V0)
MIL-STD-810D
5% to 95% RH
4 pcs per Tube
Perf. Criteria B
Perf. Criteria B
Perf. Criteria B
Perf. Criteria B
Perf. Criteria B
50 / 75mVp-p
1000pF max.
300kHz typ.
9.2°C/Watt
8.5°C/Watt
2.8°C/Watt
150% max
120mVp-p
150mVp-p
1 GΩ min.
1600VDC
EN60950
50mVp-p
75mVp-p
Class A
Class A
P-91
3
100°C
300µs
hours
3.9V
6.2V
15V
18V
60g

Related parts for RP40-240515TG/HC