NPX20S24025DC Murata Power Solutions Inc, NPX20S24025DC Datasheet - Page 2

CONV DC/DC 6A 24VIN 2.5VOUT SGL

NPX20S24025DC

Manufacturer Part Number
NPX20S24025DC
Description
CONV DC/DC 6A 24VIN 2.5VOUT SGL
Manufacturer
Murata Power Solutions Inc
Series
NPX20r
Type
Isolatedr
Datasheet

Specifications of NPX20S24025DC

Output
2.5V
Number Of Outputs
1
Power (watts)
20W
Mounting Type
Through Hole
Voltage - Input
18 ~ 36V
Package / Case
6-DIP Module
1st Output
2.5 VDC @ 6A
Size / Dimension
2.02" L x 1.00" W x 0.36" H (51.3mm x 25.4mm x 9.1mm)
Power (watts) - Rated
15W
Operating Temperature
-40°C ~ 85°C
Efficiency
80%
Approvals
cUL, UL
Product
Isolated
Output Power
15 W
Input Voltage Range
18 V to 36 V
Input Voltage (nominal)
24 V
Output Voltage (channel 1)
2.5 V
Output Current (channel 1)
6 A
Isolation Voltage
1.5 KV
Package / Case Size
DIP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
 Details
Other names
811-1657
1. Absolute maximum value for 30 seconds. Prolonged operation may damage the product.
www.murata-ps.com
GENERAL CHARACTERISTICS
Parameter
Switching frequency
Remote on/off
MTTF
ABSOLUTE MAXIMUM RATINGS
Input voltage, 24V input types
Input voltage, 48V input types
Output voltage
Output trim control
Remote On/Off
ISOLATION CHARACTERISTICS
Parameter
Isolation test voltage
Resistance
Capacitance
ENVIRONMENTAL CHARACTERISTICS
Parameter
Substrate temperature
Storage
Thermal protection
EMC FILTERING AND SPECTRA
TECHNICAL NOTES
ISOLATION VOLTAGE
‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test voltage,
applied for a specifi ed time, across a component designed to provide electrical isolation, to verify the integrity of that isolation.
Murata Power Solutions NPX20 series of dc/dc converters are all 100% production tested at their stated isolation voltage. This is 1500V DC for 1 second.
A question commonly asked is, “What is the continuous voltage that can be applied across the part in normal operation?”
The NPX20S series has been recognized by Underwriters Laboratory to UL 60950 Basic Insulation class, and may be used as part of safety isolation scheme, provided that the out-
put is maintained within SELV limits and the input is connected to a TNV or SELV supply. The isolation test voltage represents a measure of immunity to transient voltages. The part
can be expected to function with several hundred volts offset applied continuously across the isolation barrier; but then the circuitry on both sides of the barrier must be regarded
as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user accessible circuitry according to safety standard
requriements.
REPEATED HIGH-VOLTAGE ISOLATION TESTING
It is well known that repeated high-voltage testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials, construc-
tion and environment. While manufactured parts can withstand several times the stated test voltage, any material is susceptible to eventual degradation when subjected to very
high applied voltages, thus implying that the number of tests should be strictly limited. We therefore strongly advise against repeated high voltage testing, but if it is absolutely
requried, that the voltage be reduced by 20% from the specifi ed test voltage.
EMC FILTER AND VALUES
C1 4.7μF 100V Polyester capacitor
C2 4.7nF 250 VAC Y rated
C3 33μF ESR <0.7 Ω 100V Electrolytic capacitor
Recommended EMC fi lter should reduce conducted emissions below EN 55022 curve B Quasi-peak average limit.
1
1
Conditions
Module on (open collector input)
Module off
MIL HDBK 217F
Conditions
Full load
Absolute Max. internal temperature
Operates at substrate temperature
Conditions
Flash tested for 1 second
VISO = 500VDC
Technical enquiries email: mk@murata-ps.com, tel: +44 (0)1908 615232
Isolated 20W Single Output DC/DC Converters
487000
Min.
Min.
-1.0
-1.0
-40
-40
1500
Min.
000
1
2010/02/08 KDC_NPX20C.I01 Page 2 of 8
Typ.
Typ.
350
100
Typ.
NPX20 Series
65
Max.
Max.
125
0.5
Max.
85
-0.5V / +V
-0.5V / +V
0.5V
40V
80V
OUT
OUT
Units
Units
kHrs
Units
kHz
mA
VDC
°C
°C
°C
pF
V

Related parts for NPX20S24025DC