OKX-T/10-D12P-C Murata Power Solutions Inc, OKX-T/10-D12P-C Datasheet

CONVERT DC/DC SIP 50W 0.75-5.5V

OKX-T/10-D12P-C

Manufacturer Part Number
OKX-T/10-D12P-C
Description
CONVERT DC/DC SIP 50W 0.75-5.5V
Manufacturer
Murata Power Solutions Inc
Series
Okami™ OKX-T/10-D12r
Type
Point of Load (POL) Non-Isolatedr
Datasheets

Specifications of OKX-T/10-D12P-C

Number Of Outputs
1
Output
0.75 ~ 5.5V
Power (watts)
50W
Mounting Type
Through Hole
Voltage - Input
8.3 ~ 14V
Package / Case
11-SIP Module
1st Output
0.75 ~ 5.5 VDC @ 10A
Size / Dimension
2.00" L x 0.37" W x 0.50" H (50.8mm x 9.4mm x 12.7mm)
Power (watts) - Rated
50W
Efficiency
94.5%
Approvals
cUL, EN, UL
Output Power
55 W
Input Voltage Range
8.3 V to 14 V
Input Voltage (nominal)
12 V
Output Voltage (channel 1)
0.7525 V to 5.5 V
Output Current (channel 1)
10 A
Output Voltage (channel 2)
0.7525 V to 5.5 V
Output Current (channel 2)
10 A
Output Voltage (channel 3)
0.7525 V to 5.5 V
Output Current (channel 3)
10 A
Package / Case Size
SIP
Output Type
Adjustable Output DC/DC Converters
Output Voltage
0.7525 V to 5.5 V
Product
Non-Isolated / POL
Dc / Dc Converter O/p Type
Adjustable
No. Of Outputs
1
Input Voltage
8.3V To 14V
Power Rating
50W
Output Current
10A
Approval Bodies
EN / FCC / IEC / UL
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Operating Temperature
-
3rd Output
-
2nd Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
811-2010-5
www.murata-ps.com
Non-isolated SIP POL DC/DC power module
8.3-14Vdc input voltage range
Programmable output voltage from 0.7525-5.5Vdc
10 Amp (T/10) or 16 Amp (T/16) output current
models
Drives 1000 μF ceramic capacitive loads
High power conversion effi ciency 94.5% at 3.3
Vout
Outstanding thermal derating performance
Over temperature and over current protection
On/Off control, Sense and optional Sequence/
Tracking input
UL/EN/IEC 60950-1 safety
Industry-standard (DOSA) SIP format
RoHS-6 hazardous substance compliance
External
DC
Power
Source
For full details go to
Sequence/Tracking (optional)
F1
 
Open = On
Closed = Off
Common
Typical unit
+Vin
(Positive
Control
On/Off
On/Off)
Note: Murata Power Solutions strongly recommends an external input fuse, F1.
See specifi cations.
Controller
SIP non-isolated Point-of-Load (POL) DC/DC power
converters for embedded applications. The module
is fully compatible with Distributed-power Open
Standards Alliance (DOSA) industry-standard
specifi cations (www.dosapower.com). Applications
include powering CPU’s, datacom/telecom systems,
programmable logic and mixed voltage systems.
maximum output currents are offered, 10 Amps
(T/10 models) or 16 Amps (T/16 models). Based
on fi xed-frequency synchronous buck converter
switching topology, the high power conversion
The OKX-T/10 and -T/16 series are miniature
The wide input range is 8.3 to 14 Volts DC. Two
www.murata-ps.com
Description, Connection Diagram, Photograph
Ordering Guide, Model Numbering
Mechanical Specifi cations, Input/Output Pinout
Detailed Electrical Specifi cations
Output Voltage Adjustment, Soldering Guidelines, Product Label
Application Notes
OKX2-T/10-D12 Performance Data
OKX2-T/16-D12 Performance Data and Oscillograms
Reference and
Error Amplifier
Adjustable DOSA 10/16-Amp SIP DC/DC Converters
effi cient Point of Load (POL) module features pro-
grammable output voltage and On/Off control. An
optional Sequence/Tracking input allows controlled
ramp-up and ramp-down outputs. The Sense input
provides load compensation. These converters also
include under voltage lock out (UVLO), output short
circuit protection, over-current and over tempera-
ture protections.
UL/EN/IEC 60950-1 safety and FCC EMI/RFI
emissions certifi cations and RoHS-6 hazardous
substance compliance.
These units are designed to meet all standard
Common
Sense
+Vout
Trim
10
12
1
2
3
5
6
7
Page 1 of 16

Related parts for OKX-T/10-D12P-C

OKX-T/10-D12P-C Summary of contents

Page 1

... See specifi cations.   For full details go to Adjustable DOSA 10/16-Amp SIP DC/DC Converters The OKX-T/10 and -T/16 series are miniature SIP non-isolated Point-of-Load (POL) DC/DC power converters for embedded applications. The module is fully compatible with Distributed-power Open Standards Alliance (DOSA) industry-standard specifi ...

Page 2

The input voltage range must be 13.2 Volts max. for Vout >= 3.63 V. ...

Page 3

TYP 4.45 .175 10.16 .400 RECOMMENDED FOOTPRINT -TOP VIEW 50.8 2.00 12.7 . 2.54 .100 TYP 12.70 35.56 .500 1.400 MATERIAL: PINS: ...

Page 4

... Output 9* *Sequence/Tracking 5 Common 10 11 On/Off Control *Sequence/Tracking is standard for OKX2. On OKX models, Pin 9 is omitted. Dimensions are in inches (mm shown for ref. only). Tolerances (unless otherwise specified): 0.76 .XX ± 0.02 (0.5) .030 .XXX ± 0.010 (0.25) TYP Angles ± 1˚ 1.27 ...

Page 5

... Vout=nominal Isolation Not isolated Safety Designed to meet UL/cUL 60950-1, CSA-C22.2 No. 60950-1, IEC/EN 60950-1 Calculated MTBF per Telcordia SR-232 (4a) 6.54 mHRS (OKX2-T/16-D12P) Calculated MTBF per MIL-HDBK-217F (4b) 5.3 mHRS (OKX2-T/16-D12P) Output Voltage Range See Ordering Guide Minimum Loading No minimum load Accuracy (50% load, untrimmed) ± ...

Page 6

If the overcurrent condition still exists, the restart current will be removed and then tried again. This short current pulse prevents overheating and damaging the ...

Page 7

Certain applications and/or safety agencies may require fuses at the inputs of power conversion components. Fuses should also be used when there is the possibility of sustained input voltage reversal which is not current-limited. We recommend a time delay fuse ...

Page 8

In the fi gure, the two copper strips simulate real-world printed circuit impedances between the power supply and its load. In order to minimize circuit errors and standardize tests between units, scope measurements should be made using BNC connectors or ...

Page 9

On the input side, a remote On/Off Control can be ordered with either polarity. Please refer to the Connection Diagram on page 1 for On/Off connections. Positive polarity models are enabled when the On/Off pin is left open or is ...

Page 10

... Adjustable DOSA 10/16-Amp SIP DC/DC Converters OKX2-T/10-D12-C Maximum Current Temperature Derating at Sea Level 11 10.5 10 9 OKX2-T/10-D12 Effi ciency vs. Line Voltage and Load Current @ +25° OKX2-T/10-D12 Effi ciency vs. Line Voltage and Load Current @ +25° 1.5V) OUT 12V 14V www.murata-ps.com (V = 12V ...

Page 11

... 14V Adjustable DOSA 10/16-Amp SIP DC/DC Converters OKX2-T/10-D12-C Maximum Current Temperature Derating at Sea Level 11 10.5 10 9 OKX2-T/10-D12 Effi ciency vs. Line Voltage and Load Current @ +25° 2.5V) OUT 12V 14V OKX2-T/10-D12-C Maximum Current Temperature Derating at Sea Level 11 10.5 10 9 www ...

Page 12

... PERFORMANCE DATA OKX2-T/10-D12 Effi ciency vs. Line Voltage and Load Current @ +25° 5V) OUT 8. 12V 14V OKX2-T/16-D12 Effi ciency vs. Line Voltage and Load Current @ +25° 0.7525V) OUT 8. 12V 14V OKX2-T/16-D12 Output Ripple and Noise (Vin=12V, Vout=0.75V, Iout=16A, Cin=1000μF, Cload=1μF // 10μF, ScopeBW=100MHz) ...

Page 13

... V = 12V 14V OKX2-T/16-D12 Step Load Transient Response (Vin=12V, Vout=1.5V, Cin=1000μF, Cload=0, Adjustable DOSA 10/16-Amp SIP DC/DC Converters OKX2-T/16-D12 Effi ciency vs. Line Voltage and Load Current @ +25° OKX2-T/16-D12 Output Ripple and Noise (Vin=12V, Vout=1.5V, Iout=16A, Cin=1000μ Iout=8A to 16A to 8A) Trace1=Vout, 200 mV/div., Trace4=Iout, 5A/div. ...

Page 14

... Adjustable DOSA 10/16-Amp SIP DC/DC Converters OKX2-T/16-D12-C Maximum Current Temperature Derating at Sea Level 17 16.5 16 15.5 15 14.5 14 13.5 13 12.5 12 11.5 11 10 OKX2-T/16-D12 Effi ciency vs. Line Voltage and Load Current @ +25° 2.5V) OUT 12V 14V OKX2-T/16-D12-C Maximum Current Temperature Derating at Sea Level 17 16 ...

Page 15

... PERFORMANCE DATA OKX2-T/16-D12 Output Ripple and Noise (Vin=12V, Vout=3.3V, Iout=16A, Cin=1000μF, Cload=1μF // 10μF, ScopeBW=100MHz) OKX2-T/16-D12 Effi ciency vs. Line Voltage and Load Current @ +25° 5V) OUT 8. 12V 14V Adjustable DOSA 10/16-Amp SIP DC/DC Converters OKX2-T/16-D12-C Step Load Transient Response (Vin=12V, Vout=3.3V, Cin=1000μF, Cload=0, Iout=8A to 16A to 8A) Trace1=Vout, 200 mV/div ...

Page 16

... ISO 9001 and 14001 REGISTERED Adjustable DOSA 10/16-Amp SIP DC/DC Converters OKX2-T/16-D12-C On/Off Enable Startup Delay (Vin=12V, Vout=5V, Iout=16A, Cin=1000μF, Iout=8A to 16A to 8A) Trace1=Vout, 200 mV/div., Trace4=Iout, 5A/div. Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifi ...

Related keywords