PXF4024T0512 TDK Corporation, PXF4024T0512 Datasheet

DC-DC CONVT 5,+/-12V 6.0,+/-.40A

PXF4024T0512

Manufacturer Part Number
PXF4024T0512
Description
DC-DC CONVT 5,+/-12V 6.0,+/-.40A
Manufacturer
TDK Corporation
Series
PXFr
Type
Point of Load (POL) Non-Isolated with Remote On/Offr
Datasheets

Specifications of PXF4024T0512

Output
5V, ±12V
Number Of Outputs
3
Power (watts)
40W
Mounting Type
Through Hole
Voltage - Input
18 ~ 36V
Package / Case
9-DIP Module
1st Output
5 VDC @ 6A
2nd Output
12 VDC @ 400mA
3rd Output
-12 VDC @ 400mA
Size / Dimension
2.00" L x 2.00" W x 0.40" H (50.8mm x 50.8mm x 8.6mm)
Power (watts) - Rated
40W
Operating Temperature
-40°C ~ 100°C
Efficiency
87%
Approvals
CE, CSA, EN, UL
Dc / Dc Converter O/p Type
Fixed
No. Of Outputs
3
Input Voltage
18V To 36V
Power Rating
40W
Output Voltage
5V
Output Current
6A
Output Voltage 2
+12V
Output Current 2
+0.400A
Output Voltage 3
-12V
Brand/series
PXF Series
Configuration
Enclosed
Frequency, Switching
300 KHz
Operation
Switching
Power, Output
40 W
Power, Rating
40 W
Primary Type
DC-DC Converter
Regulation, Line
± 1% (Main), ± 5% (Auxiliary)
Regulation, Load
± 2% (Main), ± 5% (Auxiliary)
Special Features
Remote On/Off
Temperature, Operating
-40 to +100 °C
Voltage, Input
18 to 36 VDC
Voltage, Input Range
18 to 36 VDC
Voltage, Output
-12, 5, +12 VDC
Voltage, Output 1
5 VDC
Voltage, Output 2
12 VDC
Voltage, Output 3
-12 VDC
Weight
2.11 Oz.
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
285-1565
PXF40-24T0512
F e a t u r e s & B e n e f i t s
S p e c i f i c a t i o n s
Feature
ITEMS
Maximum Output Power
Voltage Accuracy (Full Load, Nom. Vin)
Voltage Adjustment
Minimum Load, each output
Line Regulation
Load Regulation (10% to 100%)
Cross Regulation (25% to 100%)
Start up time
Remote on/off (referenced to negative input)
Temperature Coefficient
Operating Temperature
Maximum Case Temperature
Storage Temperature
Thermal Shock
Relative Humidity (non condensing)
Transient Response (25% step load change)
Overvoltage Protection (Zener clamp)
Overcurrent and Short Circuit Protection
Input Surge Voltage (Maximum for 100ms)
Reflected input ripple (peak to peak)
Isolation Voltage
Isolation Resistance
Isolation Capacitance (max)
Switching Frequency (Fixed)
MTBF (BELLCORE TR-NWT-000332)
Vibration
Conducted and Radiated Emissions
Immunity
Safety Agency Approval
Size (L x W x H)
Weight
Warranty
(1) Maximum output deviation is 10% inclusive of remote sense and trim. If remote sense is not being used, the +Sense and - Sense should be connected to their corre-
(2) Dual and Triple output models require a minimum load of 10% on the output to maintain specified regulation. No load operation will not damage the device.
(3) Load regulation for triple output: Main output:10-100%, with 10-100% balanced load on auxiliaries. Auxiliary outputs: 10% to 100% balanced on all outputs.
(4) Cross regulation for dual output: asymmetrical load 25% / 100% full load. Cross regulation for triple output: Main output 100% load, auxiliary 100%, other auxiliary
(5) An external filter capacitor is required for normal operation. The capacitor should be capable of handling a 1A ripple current for 48V and 24V models.
(6) Simulated Source impedence of 12uH placed in series with + input.
sponding outputs; + output, -output.
25% to 100%. Auxiliary outputs: main output 100% load, auxiliary 100%, other auxiliary 25% to 100% or main output 25%, auxiliary 25%, other auxiliary 25% to 100%.
UL, CSA, EN, CE approvals
Wide range input
Six sided shielding
3055 Del Sol Blvd • San Diego, CA 92154 • 1-800-526-2324
Single, Dual, Triple Output 40W & 60W DC-DC Converters
(1)
(2)
(3)
(4)
(6)
PXF40: 1,398,000; PXF40xxW: 1,105,000, PXF60: 1.093,000 hours
Single ±0.5%, Dual ±1%, Triple (main) ±2%, Triple (auxiliary) ±5%
IEC60950-1, UL60950-1, EN60950-1, CE Mark (48V input only)
Single / Dual ±0.5%, Triple (main) ±1%, Triple (auxiliary) ±5%
Single Output = 0%, Dual and Triple = 10% of full load rating
Positive Logic: ON: Open or 3.0-12V, OFF Short or <1.2V
Single, Dual and Triple Main ±1%, Triple Auxiliaries ±5%
Input - Output, Input to Case: 1600VDC minimum
PXF40: 25ms typ., PXF40xxW, PXF60: 20ms max.
12V input: 36V, 24V input: 50V, 48V input: 100V
PXF40: 100°C, PXF40-xxW 105°C, PXF60 110°C
Typical 3.3V: 3.9V, 5V: 6.2V, 12V: 15V, 15V: 18V
PXF40: -55 to 105°C, PXF40xxW, PXF60 125°C
Triple (main) ±1%, Dual/Triple (auxiliary) ±5%
Benefit
10 - 55Hz, 10G, 30 minutes each X, Y, Z axis
K e y M a r k e t S e g m e n t s & A p p l i c a t i o n s
PXF Series
Telecom, Datacom, Point of Load
PXF40, PXF60: 1000pF, PXF40xxW: 2500pF
Typically at 150%, hiccup with self recovery
EN55022 Level A, see installation manual
PXF40: 40mA, PXF40xxW, PXF60: 20mA
Easier system approvals
Less parts to inventory
Reduced radiated noise
±10% (Single and Dual Output Only)
Industry Standard 2" x 2" Footprint
Six Sided Shielding
Agency Approved
12, 24V, and 48V Inputs (including 4:1 ranges)
EN61000-4-2, -3, -4, -5, -6
10
See derating curves
250us recovery
9
MIL-STD-810F
2.11 oz (60g)
<±0.02%/°C
300kHz (typ.)
40W or 60W
Ohms minimum
2 x 2 x 0.4"
5 to 95%
Two Year
155

Related parts for PXF4024T0512

PXF4024T0512 Summary of contents

Page 1

Single, Dual, Triple Output 40W & 60W DC-DC Converters & Feature UL, CSA, EN, CE approvals Wide range input Six sided shielding S p ...

Page 2

Model Selector Output Output Input Volt(V) Curr(A) Volt(VDC) Model Single Outputs 3 PXF40-12S3P3 3 PXF40-24WS3P3 3 PXF40-24S3P3 3 PXF40-48WS3P3 3 ...

Related keywords