OKY-T/10-D12P-C Murata Power Solutions Inc, OKY-T/10-D12P-C Datasheet
OKY-T/10-D12P-C
Specifications of OKY-T/10-D12P-C
Related parts for OKY-T/10-D12P-C
OKY-T/10-D12P-C Summary of contents
Page 1
... For full details go to www.murata-ps.com/rohs Programmable DOSA-SMT 10/16-Amp DC/DC Converters PRODUCT OVERVIEW The OKY-T/10 and -T/16 series are miniature SMT non-isolated Point-of-Load (POL) DC/DC power converters for embedded applications. The module is fully compatible with Distributed-power Open Standards Alliance (DOSA) industry-standard specifi ...
Page 2
... Performance Specifi cations and Ordering Guide ORDERING GUIDE I OUT V (Amps Power OUT ➂ Model Number (Volts) max) (Watts) OKY-T/10-D12P-C 0.7525-5 OKY-T/10-D12N-C 0.7525-5 OKY2-T/10-D12P-C 0.7525-5 OKY2-T/10-D12N-C 0.7525-5 OKY-T/16-D12P-C 0.7525-5 OKY-T/16-D12N-C 0.7525-5 OKY2-T/16-D12P-C 0.7525-5 OKY2-T/16-D12N-C 0.7525-5 ➀ Dimensions are in inches (mm). ➁ The input voltage range must be 13.2 Volts max. for Vout >= 3.63 V. ...
Page 3
... The Remote On/Off can be provided with either positive (P suffi negative (N suffi x) polarity. ** Vtrack Seq applies only to OKY2 models. No connection for OKY models. email: sales@murata-ps.com 18 Oct 2010 MDC_OKY_T10T16.D12.A06 Page Function P66 On/Off Control * +Vin Vtrack Seq** Gnd (Common) ...
Page 4
... V.to +15 Volts max. (D12 models min. to +Vin max. See Fuse section Current-limited. Devices can withstand a sustained short circuit without damage. The outputs are not intended to accept appreciable reverse current. -55 to +125° C. See soldering specifi cations email: sales@murata-ps.com MDC_OKY_T10T16.D12.A06 Page ...
Page 5
... Less than 3 ºC. per second Peak Temp. 235-260° C Reflow Zone Soaking Zone time above 217° C 45-75 sec 120 sec max Preheating Zone 240 sec max 90 120 150 180 210 240 270 Time (sec) email: sales@murata-ps.com MDC_OKY_T10T16.D12.A06 Page 300 ...
Page 6
... To prevent many over temperature problems and damage, these converters include thermal shutdown circuitry. If environmental conditions cause the temperature of the DC/DC’s to rise above the Operating Temperature Range www.murata-ps.com 18 Oct 2010 -T/10 & T/16-D12 Series CURRENT PROBE +INPUT C IN -INPUT email: sales@murata-ps.com MDC_OKY_T10T16.D12.A06 Page ...
Page 7
... Negative polarity devices are on (enabled) when the On/Off pin is left open or brought to within a low voltage (see Specifi cations) with respect to –Vin. The device is off (disabled) when the On/Off is pulled high (see Specifi cations) with respect to –Vin. www.murata-ps.com OKY -T/10 & T/16-D12 Series email: sales@murata-ps.com 18 Oct 2010 MDC_OKY_T10T16.D12.A06 Page ...
Page 8
... ESD diodes. This feature is variously called “mono- tonic” because the voltage does not decay or produce a negative transient once the input power is applied and startup begins. Sequence/Tracking operation is not available during pre-bias startup. www.murata-ps.com 18 Oct 2010 -T/10 & T/16-D12 Series email: sales@murata-ps.com MDC_OKY_T10T16.D12.A06 Page ...
Page 9
... 14V Load Curre nt (Amps) Programmable DOSA-SMT 10/16-Amp DC/DC Converters OKY2-T/10-D12 Effi ciency vs. Line Voltage and Load Current @ +25° OKY2-T/10-D12 Effi ciency vs. Line Voltage and Load Current @ +25° OKY2-T/10-D12 Effi ciency vs. Line Voltage and Load Current @ +25° www.murata-ps.com OKY -T/10 & T/16-D12 Series ...
Page 10
... PERFORMANCE DATA – OKY2-T/10-D12 OKY2-T/10-D12 Effi ciency vs. Line Voltage and Load Current @ +25° 3.3V) OUT 8. 12V 14V Load Curre nt (Amps) OKY2-T/10-D12-C Maximum Current Temperature Derating at Sea Level Programmable DOSA-SMT 10/16-Amp DC/DC Converters OKY2-T/10-D12 Effi ciency vs. Line Voltage and Load Current @ +25°C ...
Page 11
... OKY2-T/16-D12-C Maximum Current Temperature Derating at Sea Level OKY2-T/16-D12 Effi ciency vs. Line Voltage and Load Current @ +25° OKY2-T/16-D12 Effi ciency vs. Line Voltage and Load Current @ +25° 1.5V) OUT 12V 14V Load Curre nt (Amps) www.murata-ps.com OKY -T/10 & T/16-D12 Series (V = 12V 0.75V). IN ...
Page 12
... PERFORMANCE DATA AND OSCILLOGRAMS – OKY2-T/16-D12 On/Off Enable Startup Delay (Vin=8.3V, Vout=1.5V, Iout=16A, Cload=0) Trace 4=Enable In, Trace2=Vout Step Load Transient Response (Vin=12V, Vout=1.5V, Cload=0, Iout=8A to 16A) Trace 2=Vout, 100 mV/div., Trace4=Iout, 5A/div. OKY2-T/16-D12 Effi ciency vs. Line Voltage and Load Current @ +25° 1.8) OUT 90 ...
Page 13
... On/Off Enable Startup Delay (Vin=8.3V, Vout=2.5V, Iout=16A, Cload=0) Trace 4=Enable In, Trace2=Vout Step Load Transient Response (Vin=12V, Vout=2.5V, Cload=0, Iout=8A to 16A) Trace 2=Vout, 100 mV/div., Trace4=Iout, 5A/div. Programmable DOSA-SMT 10/16-Amp DC/DC Converters OKY2-T/16-D12 Effi ciency vs. Line Voltage and Load Current @ +25° 2.5V) OUT ...
Page 14
... PERFORMANCE DATA AND OSCILLOGRAMS – OKY2-T/16-D12 OKY2-T/16-D12 Effi ciency vs. Line Voltage and Load Current @ +25° 3.3V) OUT 8. 12V 14V Load Curre nt (Amps) On/Off Enable Startup Delay (Vin=8.3V, Vout=3.3V, Iout=16A, Cload=0) Trace 4=Enable In, Trace2=Vout Step Load Transient Response (Vin=12V, Vout=3.3V, Cload=0, Iout=8A to 16A) Trace 2=Vout, 100 mV/div ...
Page 15
... PERFORMANCE DATA AND OSCILLOGRAMS – OKY2-T/16-D12 OKY2-T/16-D12 Effi ciency vs. Line Voltage and Load Current @ +25° 5V) OUT 8. 12V 13. Load Curre nt (Amps) On/Off Enable Startup Delay (Vin=8.3V, Vout=5V, Iout=16A, Cload=0) Trace 4=Enable In, Trace2=Vout Step Load Transient Response (Vin=12V, Vout=5V, Cload=0, Iout=8A to 16A) Trace 2=Vout, 100 mV/div., Trace4=Iout, 5A/div. ...
Page 16
... REF 13.00 .27 www.murata-ps.com OKY -T/10 & T/16-D12 Series ROUND HOLES PIN 1.75 #1 .069 40.40 1.591 OBLONG HOLES THIRD ANGLE PROJECTION 44.0 101.6 1.73 4.00 REF (CORE) .512 REEL INFORMATION (250 UNITS PER REEL) email: sales@murata-ps.com 18 Oct 2010 MDC_OKY_T10T16.D12.A06 Page 9.14 .360 ...
Page 17
... OKY2-T/16-D12N-C 5,506,128 Murata Power Solutions, Inc. 11 Cabot Boulevard, Mansfi eld, MA 02048-1151 U.S.A. ISO 9001 and 14001 REGISTERED OKY Programmable DOSA-SMT 10/16-Amp DC/DC Converters Model Number OKY-T/10-D12P-C OKY-T/10-D12N-C OKY2-T/10-D12P-C OKY2-T/10-D12N-C OKY-T/16-D12P-C OKY-T/16-D12N-C OKY2-T/16-D12P-C OKY2-T/16-D12N-C The manufacturing date code is four characters: First character – ...