S8VM-15024CD Omron, S8VM-15024CD Datasheet - Page 16

POWER SUPPLY 24V 6.5A COVERED

S8VM-15024CD

Manufacturer Part Number
S8VM-15024CD
Description
POWER SUPPLY 24V 6.5A COVERED
Manufacturer
Omron
Series
S8VMr
Datasheets

Specifications of S8VM-15024CD

Voltage - Output
24V
Number Of Outputs
1
Power (watts)
150W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
100 ~ 240VAC
Mounting Type
DIN Rail
1st Output
24 VDC @ 6.5A
Size / Dimension
6.32" L x 1.54" W x 3.25" H (160.5mm x 39.1mm x 82.5mm)
Power (watts) - Rated
150W
Operating Temperature
-10°C ~ 60°C
Efficiency
83%
Approvals
CE, CSA, cUL, cUR, EN, TUV, UL
Product
Switching
Mounting Style
DIN Rail
Open Frame/enclosed
Enclosed
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
S8VM15024CD
Z2500
■ Remote Control Function
This function turns outputs ON and OFF using an external signal
while input voltage is applied, using the +RC pin (pin 7 on CN) and
the -RC pin (pin 8 on CN). Connect a switch or transistor to the +RC
and -RC pins to use the remote control function. When not using this
function, the +RC and -RC pins are shorted by using the standard
supplied connector.
Maximum input voltage: 12 V max.
Maximum allowable reverse voltage: − 1 V max.
Sink Current: 3.5 mA
Note: 1. Use 2-conductor shielded cable or twisted-pair cable as
■ Power Failure Alarm Function
The power failure alarm indicator will light red to indicate an output
voltage error if overload, overvoltage, or overheat protection is acti-
vated, if a drop in the input voltage causes the output voltage to drop,
if the built-in fan motor stops, and during remote control standby. The
alarm is also output externally by a transistor.
Transistor output: 30 VDC max., 50 mA max.
Residual voltage when ON: 2 V max.
Leakage current when OFF: 0.1 mA max.
Alarm detection voltage: Approx. 80% of output voltage setting
During detection, the transistor is OFF (with no continuity across pins
11 and 12 on CN), and the LED (red) lights.
Note: 1. This function monitors the voltage at the Power Supply out-
16
Short or L (0 to 0.8 V) ON
Open or H (2.4 to 12 V) OFF
+ RC Level for − RC
2. The remote control circuit is isolated from the input and out-
3. Remove the standard supplied connector and prepare a
2. Outputs are forced OFF if the built-in fan motor stops
3. Remove the standard supplied connector and prepare a
connection wire.
put circuits of the power supply.
connector separately.
put terminals. To check actual voltage, measure the voltage
on the load side.
(S8VM-15224C only).
connector separately.
Switch Mode Power Supply
S8VM
S8VM
CN
CN
Output
PF-C
PF-E
+RC
−RC
Vce max.: 30 VDC
Ic max.: 50 mA
SW
Rotate
Stop
Built-in Fan Motor
S8VM
TR
■ Inrush Current, Start Up Time,
■ Input Current Waveform When
(The following examples show typical waveforms.)
S8VM-300@@C
100 VAC, Load ratio: 100%
200 VAC, Load ratio: 100%
AC input
AC input
(10 A/DIV)
(10 A/DIV)
voltage
voltage
current
Output
AC input
AC input
AC input
AC input
voltage
voltage
voltage
voltage
current
current
Output
Output Hold Time
Input Is Turned ON
Output
Input ON
Inrush current on input application
100 ms
100 ms
Start up time
90%
Hold time
Input OFF
95%

Related parts for S8VM-15024CD