HWS150-15/A TDK Corporation, HWS150-15/A Datasheet

PWR SUP IND 15V 10A SNG OUTPUT

HWS150-15/A

Manufacturer Part Number
HWS150-15/A
Description
PWR SUP IND 15V 10A SNG OUTPUT
Manufacturer
TDK Corporation
Series
HWSr
Type
Industrialr
Datasheets

Specifications of HWS150-15/A

Voltage - Output
15V
Number Of Outputs
1
Power (watts)
150W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
85 ~ 265VAC
Mounting Type
Chassis Mount
1st Output
15 VDC @ 10A
Size / Dimension
6.3" L x 1.65" W x 3.23" H (160mm x 41.9mm x 82mm)
Power (watts) - Rated
150W
Operating Temperature
-10°C ~ 70°C
Efficiency
86%
Approvals
CE, CSA, EN, IEC, UL
Application
Process control, NC-machining, automotive, packaging equipment, materials handling, chemical processing, robots, burn-in and test, automated test, instrumentation, detection and measurement
Brand/series
HWS Series
Configuration
Enclosed
Current, Rating
10 A (Max.)
Load Regulation
120 mV
Operation
Switching
Output
15 VDC @ 10 A
Power, Output
150 W
Primary Type
AC-DC
Regulation, Line
60 mV
Special Features
PFC, Remote Sense
Standards
Approved to UL, CSA Certified
Temperature Coefficient
0.02%⁄°C (Max.)
Temperature, Operating
-10 to +70 °C
Voltage, Input
85 to 265/120 to 370 VAC/VDC
Voltage, Output
15 VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
RoHS Compliant part
Other names
285-1298
HWS15015/A

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HWS150-15/A
Manufacturer:
TDK-LAMBDA
Quantity:
320
Features and Benefits
Feature
Specifications
ITEMS
Input Voltage range
Input Current (Typ) (1)
Inrush Current (1)
Power Factor
Temperature Coefficient
Overcurrent Protection
Overvoltage Protection
Hold Up Time (Typ)
Leakage Current (max)
Remote Sense
Indicator
Operating Temperature (no cover)
Storage Temperature
Humidity (non condensing)
Cooling
Withstand Voltage
Isolation Resistance
Vibration (non operating)
Shock
Safety Agency Certifications
Line Dip
Conducted & Radiated EMI
Recommended EMI Filter
Immunity
Weight (Typ)
Size (WxHxD)
Size (WxHxD) /A version
Warranty
(1) 100/200VAC
(2) -40°C Start up, see options table
Limited Lifetime Warranty
High Efficiency
Wide Range AC Input
MODELS
3055 Del Sol Blvd • San Diego, CA 92154 • 1-800-526-2324
mA
ms
°C
°C
in
A
A
V
g
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
1.04x3.23x3.15
1.24x3.23x3.15
Input to Ground 2kVAC, Input to Output 3kVAC, Output to Ground 500VAC for 1 min.
0.4 / 0.2
HWS15
180
UL60950-1, CSA60950-1, EN60950-1, EN50178, UL508, CE Mark
IEC61000-4-2 (Level 3,2), -3, -4, -5, -6 (Level 3), -8, -11 (Level 4)
-10°C to +70°C, derate linearly to 20% load from 50°C to 70°C
10 - 55Hz (1 minute sweep), 19.6m/s
Limited lifetime warranty (See Lambda’s terms & conditions)
Single Output Industrial Power Supplies
>100M at 25°C & 70%RH, Output to Ground 500VDC
<0.5mA (Typ 0.3mA at 100VAC, 0.5mA at 230VAC)
Operating: 30 - 90%RH, Non operating 10 - 95%RH
1.04x3.23x3.74
1.24x3.23x3.74
RSEL-2001W
0.8 / 0.4
HWS Series
85 - 265VAC (47 - 63Hz) or 120 - 370VDC
HWS30
Complies with SEMI F47 (200VAC line only)
EN55011 / EN55022-B, FCC-B, VCCI-B
No
220
Benefit
Factory Automation
Test & Measurement
Automated Service
Key Market Segments & Applications
Lower Cost of Ownership
Easier System Cooling
Supports Global Use
(3) UL60601-1, EN60601-1, see options table
Limited Lifetime Warranty
UL508 approved
SEMI F47 Compliant (high line AC)
Universal Input (85 - 265VAC)
High Efficiency
Meets EN61000-3-2
Green LED = ON
Yes (See page 2)
1.04x3.23x4.72
1.24x3.23x4.72
-30 to +85°C
< 196.1m/s
<0.02%/°C
Convection
0.7 / 0.35
14 / 28
>104%
HWS50
280
20
2
Process Control, NC-Machining,
Automotive, Packaging Equipment,
Materials Handling,
Chemical Processing, Robots
Burn-in & Test, Automated
Test, Instrumentation,
Measurement, Detection
2
constant X, Y, Z 1 hour
1.3x3.23x6.3
RSEL-2002W
1.1x3.23x6.3
1.3 / 0.65
HWS100
450
Yes
1.46x3.23x6.3
1.65x3.23x6.3
RSEL-2003W
1.9 / 0.95
(2)
HWS150
(3)
500
59

Related parts for HWS150-15/A

HWS150-15/A Summary of contents

Page 1

... Limited lifetime warranty (See Lambda’s terms & conditions) (3) UL60601-1, EN60601-1, see options table Process Control, NC-Machining, Automotive, Packaging Equipment, Materials Handling, Chemical Processing, Robots Burn-in & Test, Automated Test, Instrumentation, Measurement, Detection HWS50 HWS100 HWS150 1.3 / 0.65 1 >104% 20 Yes (2) constant hour 2 2 ...

Page 2

... HWS30-15/A 15V 12.0 - 18.0 2 120 HWS50-15/A 15V 12.0 - 18.0 3.5 120 HWS100-15/A 15V 12.0 - 18.0 7 120 HWS150-15/A 15V 12.0 - 18.0 10 120 HWS15-24/A 24V 19.2 - 28.8 0.65 192 HWS30-24/A 24V 19.2 - 28.8 1.3 192 HWS50-24/A 24V 19.2 - 28.8 2.2 192 HWS100-24/A 24V 19 ...

Related keywords