D1U-W-1200-12-HA2C Murata Power Solutions Inc, D1U-W-1200-12-HA2C Datasheet - Page 2

POWER SUPPLY 1200W AC/DC 12V

D1U-W-1200-12-HA2C

Manufacturer Part Number
D1U-W-1200-12-HA2C
Description
POWER SUPPLY 1200W AC/DC 12V
Manufacturer
Murata Power Solutions Inc
Series
D1U-W-1200-12-Hxr
Datasheet

Specifications of D1U-W-1200-12-HA2C

Power Supply Type
Switching (Closed Frame)
Voltage - Output
12V
Number Of Outputs
1
Power (watts)
1200W
Applications
Commercial
Voltage - Input
90 ~ 140VAC, 180 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
12 VDC @ 98.3A
Size / Dimension
12" L x 4.75" W x 1.6" H (304.8mm x 120.7mm x 41mm)
Power (watts) - Rated
1200W
Operating Temperature
0°C ~ 50°C
Efficiency
90.6%
Approvals
c-CSA-us, CSA, EN, TUV, UL
Power Supply Output Type
Fixed
No. Of Outputs
2
Output Voltage
12V
Output Current
1.7A
Power Rating
1200W
Input Voltage
90V AC To 140V AC / 180V AC To 264V AC
Product
Linear
Output Power Rating
1180 W
Output Voltage (channel 1)
12 V
Output Current (channel 1)
98.3 A
Mounting Style
Rack
Dimensions
12 in L x 4.75 in W x 1.6 in H
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
811-1950
OUTPUT CHARACTERISTICS
Parameter
Remote Sense
Effi ciency
Output Rise Monotonicity
Start-up Time
Transient Response
Current sharing accuracy (up to 6 in parallel)
Hot Swap Transients
Hold-up Time
GENERAL CHARACTERISTICS
Parameter
Storage Temperature Range
Operating Temperature Range
Operating Humidity
Storage Humidity
Shock
Sinusoidal Vibration
MTBF
Acoustic
Safety Approvals
Input Fuse
Material Flammability
Switching Frequency
Weight
PROTECTION CHARACTERISTICS
Output
Voltage
ISOLATION CHARACTERISTICS
Parameter
Insulation Safety Rating / Test Voltage
Isolation
Material Flammability
Grounding
3.3Vsb
www.murata-ps.com
5Vsb
12V
Parameter
Over-temperature
Over Voltage
Over Current
Over Voltage
Over Current
Over Voltage
Over Current
Conditions
220Vac
Overshoot less than 10% for all outputs, no voltage negative between 10% to 95% during ramp up
AC ramp up
PS_On activated
12V Ramp 1A/μs, 50% load step
3.3Vsb Ramp 1A/μs, 50% load step
5Vsb Ramp 1A/μs, 50% load step
At 100% load
All outputs within regulation
Max. load, nominal Vin
Conditions
Non-condensing
Non-condensing
30G non operating
0.5G, 5 – 500 Hz operating
Calculated per Bellcore at Ta=30°C
Demonstrated
ISO 7779-1999
c-CSA-us (CSA 60950-1-03/UL 60950-1, First Edition)
TUV approval (Bauart) EN 60950-1:2001
Power Supply has internal 20A/250V fast blow fuse on the AC line input
UL 94V-0
90KHz for Boost PFC Converter
165KHz for Main Output Converter
200KHz for Standby Output Converter
2.1kg
Conditions
Auto-restart
Latching
Latching
Latching
Latching
Latching
Latching
Conditions
Input to Output - Reinforced
Input to Chassis - Basic
Output to Chassis
Output to Output
UL 94V-0
Main Output Return and Standby Output Return are connected internally. 100kΩ resistor parallel with 100nF
capacitor is connected between Return and power supply chassis. Main Output Return should be connected to
the System Chassis.
AC/DC Front End Power Supply + S1U Power Shelf
D1U-W-1200-12-Hx Series
Technical enquiries email: toronto@murata-ps.com, tel:
3000
1500
3.57
200
200
107
Min.
Min.
-40
Min.
6.5
5.6
Min.
20
10
55
13
0
5
5
90.6
120
150
1.5
Typ.
Typ.
Typ.
Typ.
CPS_D1U-W-1200-12-Hx.C07 Page 2 of 7
±600
±165
±250
4.02
±10
122
Max.
Max.
Max.
Max.
70
50
90
90
60
65
14
8
6
7
+1 (866) 740 1232
dB LpAm
Khrs
Khrs
Units
mV
Units
Units
Units
Vrms
Vrms
mV
°C
ms
ms
°C
%
%
%
V
A
V
A
V
A
s