Specifications of VSBU-120-30

Voltage - Output
30V
Number Of Outputs
1
Power (watts)
120W
Applications
Commercial
Power Supply Type
Switching (Open Frame)
Voltage - Input
90 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
30 VDC @ 4.44A
Size / Dimension
5" L x 3" W x 1.28" H (127mm x 76.2mm x 32.5mm)
Power (watts) - Rated
120W
Operating Temperature
0°C ~ 70°C
Efficiency
80%
Approvals
CB, CE, cUL, TUV
Line Regulation
±0.5%
Load Regulation
±3%
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
PART NUMBER: VSBU-120
Safety Specifications
Environmental
Dielectric withstanding voltage
Dielectric withstanding voltage
Isolation resistance
EMI requirements for CISPR-22
EMI requirements for FCC part-15
uL approved to EN6095
Operating Temperature
Storage Temperature
Relative Humidity
Derating
Parameter
Electrical Characteristics
Input Voltage
Input Frequency
Power Factor Correction
Output Power Range
Input Current (low line)
Input Current (high line)
Low Line Inrush Current
High Line Inrush Current
Efficiency
Line Regulation
Load Regulation
Over Voltage Protection
Over Current Protection
Transient Response
Hold-Up Time
Start up time
Ripple & Noise (Peak to Peak)
Safety Ground Leakage Current
Temperature Coefficient
Parameter
Parameter
V-Infinity reserves the right to make changes to its products or to discontinue any product or service without notice, and to advise customers to verify
the most up-to-date product information before placing orders. V-Infinity assumes no liability or responsibility for customer’s applications using V-Infinity
products other than repair or replacing (at V-I’s option) V-Infinity products not meeting V-I’s published specifications. Nothing will be covered outside of
standard product warranty.
20050 SW 112
th
Ave. Tualatin, Oregon 97062
Test Conditions
Primary to secondary
Primary to ground
Test voltage=500VDC
at 220VAC
at 110 VAC
Test Conditions
Derate linearly from 100% load at 50°C to 50% load at 70°C
Test Conditions
Full load at 90~260VAC
at 90 to 264 VAC
Full load at 115VAC
Full load at 230VAC
Full load, 25°C, cool start, at 115VAC
Full load, 25°C, cool start, at 230VAC
Full load, at 230VAC
Full load
at 230VAC
Full load to Half load, at 100VAC
Full load, at 110VAC
Full load, at 100VAC
Full load, at 90VAC
Full load, at 240VAC
All output
phone
phone 503.612.2300 fax
DESCRIPTION: Single Output Power Supply
fax 503.612.2382
4242
2121
Min.
-0.04
Min.
Min.
0.95
130
-40
50
112
110
0.3
90
47
70
16
B
B
0
5
0
Typ.
Typ.
Typ.
0.97
0.5
0.2
0.4
12
26
80
3
1
Max.
Max.
Max.
0.75
0.04
264
370
120
132
150
1.0
1.7
1.0
70
85
95
63
15
30
88
1
5
4
2
1
rev.
page
date
Class
Class
VDC
VDC
Unit
%/°C
Unit
VDC
MΩ
Unit
VAC
mS
mS
mA
°C
°C
Hz
%
W
%
%
%
%
%
%
A
A
A
A
S