VF-S250-48A CUI Inc, VF-S250-48A Datasheet

no-image

VF-S250-48A

Manufacturer Part Number
VF-S250-48A
Description
POWER SUPPLY 250W 48V U-FRAME
Manufacturer
CUI Inc
Series
V-Infinityr
Datasheet

Specifications of VF-S250-48A

Voltage - Output
48V
Number Of Outputs
1
Power (watts)
250W
Applications
Commercial
Power Supply Type
Switching (Open Frame)
Voltage - Input
90 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
48 VDC @ 5.21A
Size / Dimension
5.00" L x 3.20" W 1.50" H (127mm x 81.3mm x 38.1mm)
Power (watts) - Rated
250W
Operating Temperature
0°C ~ 70°C
Efficiency
83%
Approvals
CB, CE, cUL, TUV, UL
Line Regulation
±1%
Load Regulation
±1%
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Other names
102-2167
PART NUMBER: VF-S250-XXA
MODEL
notes:
features
· power factor correction
· power good signal
· short circuit protection
· over load protection
· over voltage protection
· over temperature protection
· providing Peak Power 600W within
· approved to UL, CUL, TUV, CE with CB
· low Leakage Current 500uA @ 240Vac
CUSTOM CONFIG KEY
VF-S250-05A
VF-S250-09A
VF-S250-12A
VF-S250-15A
VF-S250-18A
VF-S250-24A
VF-S250-28A
VF-S250-36A
VF-S250-48A
VF-S250-54A
300uA @ 120Vac
1 Output is fully isolated.
2 Output voltage is measured at output power connector.
3 1% minimum load is required to maintain the ripple and regulation.
4 Ripple and noise is measured from 10 KHz to 20 MHz at output terminals with a 0.1 μF ceramic capacitor and
5 Maximum power must not exceed 135 W with convection cooling or 250 W for forced air. 5 and 9 V models maximum current listed.
500uS duty duration
scheme
a 22 μF electrolytic capacitor in parallel.
20050 SW 112
voltage
preset
12V
15V
18V
24V
28V
36V
48V
54V
th
5V
9V
Ave. Tualatin, Oregon 97062
Output voltage
Input/Output connector:
“blank” = Terminal block input / Terminal block output
1 = Molex input / Molex output
2 = Molex input / Terminal block output
3 = Terminal block input / Molex output
12 - 13.5 V
13.6 - 15 V
output
16 - 20 V
21 - 26 V
27 - 34 V
35 - 42 V
43 - 50 V
51 - 60 V
2 - 5.5 V
6 - 10 V
VF-S250- XX A- X X - CXX
1, 2
convection
11.25 A
13.5 A
5.63 A
4.82 A
3.75 A
2.81 A
7.5 A
2.5 A
20 A
9 A
output current
phone
phone 503.612.2300 fax
5
DESCRIPTION: switching power supply
16 CFM
20.83 A
16.67 A
13.89 A
10.42 A
8.93 A
6.93 A
5.21 A
4.63 A
40 A
25 A
E210311
5
Low leakage option:
“blank” = standard specification
L = low leakage (contact factory)
fax 503.612.2383
regulation
+/- 1%
+/- 1%
+/- 1%
+/- 1%
+/- 1%
+/- 1%
+/- 1%
+/- 1%
+/- 1%
+/- 1%
Reserved for custom
configurations
3
ripple & noise
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
(Vpp)
www.v-infinity.com
rev.
page
date
3, 4
01/2011
1 of 5
efficiency
83%
75%
80%
83%
83%
83%
83%
83%
83%
83%

Related parts for VF-S250-48A

VF-S250-48A Summary of contents

Page 1

... VF-S250-18A 18V VF-S250-24A 24V VF-S250-28A 28V VF-S250-36A 36V VF-S250-48A 48V VF-S250-54A 54V notes: 1 Output is fully isolated. 2 Output voltage is measured at output power connector minimum load is required to maintain the ripple and regulation. 4 Ripple and noise is measured from 10 KHz to 20 MHz at output terminals with a 0.1 μF ceramic capacitor and a 22 μ ...

Page 2

... PART NUMBER: VF-S250-XXA INPUT parameter conditions/description input frequency input voltage 90-132 / 180-264 auto-selectable input current At 110-120 VAC At 200-240 VAC inrush current peak measured at 115 VAC at full load, cold start peak measured at 230 VACat full load, cold start power factor Passive Power Correction meets EN61000-3-2 class A ...

Page 3

... PART NUMBER: VF-S250-XXA GENERAL AND SAFETY parameter conditions/description operating temp 70ºC ambient, de-rating at 2.5% per degree from 50ºC to 70ºC. storage temp. operating humid. Non-condensing storage humid. Non-condensing EMI CISPR 22/EN55022 class B, EN61000-3-2, 3, EN61000-4- 11, EN55024 CE marked (LVD) safety UL60950-1, CSA C22.2 No. 60950-1, TUV EN60950-1 and CB leakage Current Regular type 1 ...

Page 4

... PART NUMBER: VF-S250-XXA FAN DRIVER CONNECTOR - (FAN) parameter conditions/description fan Suggested mating connector: JST XHP-2 or equivalent (CHYAO SHIUNN JS-2001-02) OUTPUT CONNECTOR - (CN2) parameter conditions/description output (option 1) Molex Part No. 26-48-1061 or similar (6 pin) Output pin assignment, V+ (Pins 1-3), V- (Pins 4-6) Suggested mating connector: Molex Part No. 09-91-0600 or equivalent (6) output (option 2) Howder Terminal block Part No ...

Page 5

... REV. DESCRIPTION A NEW DRAWING TOLERANCE: ±0.3mm UNLESS OTHERWISE SPECIFIED 20050 SW 112th Ave. Tualatin, OR 97062 Phone: 503-612-2300 800-275-4899 Fax: 503-612-2383 Website: www.cui.com TITLE: SWITCHING POWER SUPPLY PART NO. UNITS: VF-S250-XXA Series APPROVED BY: DRAWN BY: ZRJ DATE 6/26/2008 RoHS REV [INCHES] SCALE: 1:2 ...