S8VM-15012 Omron, S8VM-15012 Datasheet - Page 9

POWER SUPPLY 12V 12.5A OPEN FRM

S8VM-15012

Manufacturer Part Number
S8VM-15012
Description
POWER SUPPLY 12V 12.5A OPEN FRM
Manufacturer
Omron
Series
S8VMr
Datasheets

Specifications of S8VM-15012

Voltage - Output
12V
Number Of Outputs
1
Power (watts)
150W
Applications
Commercial
Power Supply Type
Switching (Open Frame)
Voltage - Input
100 ~ 240VAC
Mounting Type
Chassis Mount
1st Output
12 VDC @ 12.5A
Size / Dimension
6.32" L x 1.48" W x 3.25" H (160.5mm x 37.5mm x 82.5mm)
Power (watts) - Rated
150W
Operating Temperature
-10°C ~ 70°C
Efficiency
81%
Approvals
CE, CSA, cUL, cUR, EN, TUV, UL
Product
Switching
Mounting Style
Bottom
Open Frame/enclosed
Open Frame
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
S8VM15012
Engineering Data
■ Derating Curve
300W/600W/1,500W
Note: Refer to page 15.
Note: 1. Internal parts may occasionally be deteriorated or damaged. Do not use the Power Supply in areas outside the derating curves (i.e., the area shown by
15W/30W
Standard Mounting/Horizontal Mounting/Face-up Mounting
50W
Standard Mounting/Horizontal Mounting
100W
Standard Mounting
150W
Standard Mounting
120
100
120
100
120
100
120
100
80
60
40
20
−20
80
60
40
20
80
60
40
20
−20
−20
80
60
40
20
−20
0
0
0
0
−10
−10
−10
−10
2. If there is a derating problem, use forced air-cooling.
3. When mounting two or more Power Supplies side-by-side, allow at least 20 mm spacing between them. Multiple 100- and 150-W models cannot be used
4. When using 150-W models for a long period of time at an input voltage of 90 VAC or lower, reduce the load to 80% or less of the above derating curves.
0
0
0
0
shading A in the above graphs).
side by side. Be sure to install the Power Supplies as far away from heat-generating sources as possible. As a reference value, allow at least 50 mm spacing
on the right and left sides. If only 20 mm spacing is allowed, use the Power Supply at a load ratio of 80% or less.
Covered type
10
Covered type
10
Covered type
10
Covered type
10
20
20
20
20
30
30
30
30
Ambient temperature (°C)
Ambient temperature (°C)
Ambient temperature (°C)
Ambient temperature (°C)
40
40
40
40
50
50
50
50
Opened type
Opened type
Opened type
Opened type
60
60
60
60
A
A
A
A
70 80
70 80
70 80
70 80
(15-W, 30-W, 50-W, 100-W, 150-W Models)
Face-up Mounting
Horizontal Mounting/Face-up Mounting
Horizontal Mounting
120
100
120
100
120
100
80
60
40
20
80
60
40
20
−20
−20
80
60
40
20
0
0
−20
0
−10
−10
−10
0
Covered type
0
0
Covered type
Covered type
10
10
10
20
20
20
30
30
30
Ambient temperature (°C)
Ambient temperature (˚C)
Ambient temperature (°C)
40
40
40
Opened type
Opened type
Opened type
50
50
50
60
60
60
A
A
A
70 80
70 80
70 80
Switch Mode Power Supply
Face-up Mounting
120
100
80
60
40
20
−20
0
−10
0
Covered type
10
20
30
Ambient temperature (°C)
Opened type
40
50
S8VM
60
A
70 80
9

Related parts for S8VM-15012