SWT40-5FF TDK Corporation, SWT40-5FF Datasheet - Page 4

PWR SUP 40W +5 +15 -15V TRIPLE

SWT40-5FF

Manufacturer Part Number
SWT40-5FF
Description
PWR SUP 40W +5 +15 -15V TRIPLE
Manufacturer
TDK Corporation
Series
SWT40r
Datasheets

Specifications of SWT40-5FF

Voltage - Output
5V, ±15V
Number Of Outputs
3
Power (watts)
40W
Applications
Commercial
Power Supply Type
Switching (Open Frame)
Voltage - Input
85 ~ 265VAC
Mounting Type
Chassis Mount
1st Output
5 VDC @ 3A
2nd Output
15 VDC @ 1.5A
3rd Output
-15 VDC @ 300mA
Size / Dimension
5" L x 3" W x 1.4" H (127mm x 76.2mm x 35.6mm)
Power (watts) - Rated
40W
Operating Temperature
0°C ~ 50°C
Efficiency
70%
Approvals
CSA, DENAN, EN, UL
Line Regulation
1%, 2%
Load Regulation
2%, 4%
4th Output
-
Other names
285-1073
SWT405FF
SWT
A-276
SWT
SWT40
(*10) Peak current operation is less than 10 sec. with duty factor less than 30%. In addition, it does not has to satisfy
ITEMS/UNITS
Function
Environment
Isolation
Standards
Mechanical
Output
(*1) At 100VAC, 200VAC and MAX. OUTPUT POWER (Convection cooling), Ta=25℃.
(*2) For cases where conformance to various safety specs (UL,CSA, EN) are required to be
(*3) Please refer to Fig A for measurement determination of line & load regulation and output
(*4) From 85~132VAC / 170~265VAC, constant load.
(*5) From Min. load - Full load (Maximum power), constant input voltage.
(*6) From 0℃ ~ +50℃, constant input voltage and load.
(*7) Current limiting with automatic recovery. Avoid to operate over load or dead short for more than 30 seconds.
(*8) Over voltage clamping by zener diode.
(*9) At standard mounting method, Fig B.
Input
described as 100~120VAC, 200~240VAC, 50/60 Hz on name plate.
ripple voltage. (Measure with JEITA RC-9131 probe.)
the total regulation specification.
Voltage Range
Frequency
Efficiency (typ)
Current (100/200VAC)(typ) (*1) A
Inrush Current (100/200VAC)(typ)
Nominal Voltage
Minimum Current
Maximum Current
Maximum Peak Current (*10) A
Maximum Peak Power
Maximum Line Regulation (*3)(*4)
Maximum Load Regulation (*3)(*5)
Temperature Coefficient (*3)(*6)
Maximum Ripple & Noise (*3) mVp-p
Hold-up Time (100VAC)(typ)(*1) ms
Voltage Adjustable Range
Over Current Protection (*7)
Over Voltage Protection (*8) VDC
Output Terminals
Operating Temperature
Storage Temperature
Operating Humidity
Storage Humidity
Vibration
Shock
Cooling
Withstand Voltage
Isolation Resistance
Safety Standards
EMI
Weight
Size (W x H x D)
40
MODEL
(*2) V
(*2) Hz
(*9) ℃
(*1) %
VDC
%RH
%RH
mm
CH
W
A
A
A
g
SWT40 Specifications
I/P-O/P: 3kVAC(20mA), I/P-FG: 2.5kVAC(20mA), O/P-FG: 500VAC (100mA) for 1min
Approved by UL60950-1, CSA C22.2 No 60950-1, EN60950-1. Built to meet DENAN.
Shipment condition: CH1: ±1%, CH2(+12V): ±3%, CH2(+15V): ±5%, CH3: ±5%
0.2
4.5
+5
1
3
10 - 55Hz amplitude (sweep 1min) Less than 19.6m/s² X ,Y ,Z 1Hr each
SWT40-522
42.6 (54.6)
More than 100MΩ at Ta=25℃ and 70%RH, Output - FG 500VDC
+12
0.3
2
2
3
Convection cooling 0 to 50: 100% load; 60: 70% load
Built to meet EN55011 / EN55022-B, VCCI-B, FCC-B
All channels common ground (2 terminals)
0.3
-12
AC85 - 265 (continuously) / DC110 - 340
Automatic recovery, O.C.P point: >140%
3
0
±5V: 120; ±12V: 150; ±15V: 150
CH1: 1% , CH2: 2% , CH3: 1%
CH1: 2%, CH2: 4% , CH3: 2%
CH1 +5V fixed, CH2.3 fixed
15 / 30 (cold start, Ta=25℃)
0.2
4.5
+5
30 - 90 (No dewdrop)
10 - 95 (No dewdrop)
Less than 196.1m/s²
1
3
Convection cooling
76.2 x 127.0 x 35.6
SWT40-525
>6 (CH1 only)
40.5 (51.6)
1.11 / 0.55
-20 to +85
0.04%/℃
47 - 63
+12
280
0.3
70
17
2
2
3
・All specifications are subject to change without notice.
0.3
-5
3
0
●Recommended EMC Filter
Please refer to "TDK-Lambda
EMC Filters" catalog.
RSEL-2002W
0.2
4.5
+5
1
3
SWT40-5FF
42 (51.6)
+15
0.3
1.5
2.4
2
-15
0.3
0
3

Related parts for SWT40-5FF