GECA40HG SL Power Electronics Manufacture of Condor/Ault Brands, GECA40HG Datasheet

no-image

GECA40HG

Manufacturer Part Number
GECA40HG
Description
PWR SUP +3.3V 4A 3X5X1.25
Manufacturer
SL Power Electronics Manufacture of Condor/Ault Brands
Series
GECA40r
Datasheet

Specifications of GECA40HG

Voltage - Output
3.3V, ±12V
Number Of Outputs
3
Power (watts)
40W
Applications
Commercial
Power Supply Type
Switching (Open Frame)
Voltage - Input
90 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
3.3 VDC @ 4A
2nd Output
12 VDC @ 2A
3rd Output
-12 VDC @ 300mA
Size / Dimension
5" L x 3" W x 1.25" H (127mm x 76.2mm x 31.8mm)
Power (watts) - Rated
40W
Operating Temperature
0°C ~ 45°C
Efficiency
80%
Approvals
CE, CSA, EN, IEC, UL
Line Regulation
±0.5%, ±1%
Load Regulation
±3%, ±10%, ±5%
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
4th Output
-
Other names
271-2534
AC Input
Temperature Range
• Wide-Range AC Input 90-264 VAC
• Industry Standard Footprint - 3”x 5”x 1.25”
• Conducted EMI Exceeds FCC Class B and
• Single and Multiple Outputs
• Approved to UL60950-1: 2003, CSA-22.2 No. 60950-1-03,
• CB Report Available
• RoHS Compliant
SL Power Electronics, Corp.
CISPR 22 Class B
IEC and EN60950-1
GECA40
40 Watt Series
Commercial Wide-Range Input
Specifications
Universal Input 90-264 VAC, 47-63 Hz single phase.
Input Current
Maximum input current at 120 VAC, 60 Hz with full rated output load:
Multiple models 1.7 A, Single models 1.0 A.
Hold-Up Time
10 ms minimum with 40 W load, nominal line (120 VAC).
Output Power
40 W continuous, 45 W peak. Peak ratings are for 60 s maximum duration,
10% duty cycle. During peak load condition, output regulation may exceed
total regulation limits.
Overload Protection
Fully protected against short circuit and output overload. Short circuit
protection is cycling type power limit on V1 and V2, foldback type on V3.
Overvoltage Protection
On V1 is 120% to 160%. See chart.
Efficiency
75 to 80% at full rated load, nominal input voltage, depending on model
and load distribution.
Turn-on Time
Less than 2 seconds.
Input Protection
Internal AC fuse provided. Designed to blow only if a catastrophic failure
occurs in the unit. Fuse does not blow on overload or short circuit.
Inrush Current
Inrush is limited by internal thermistors. Inrush at 240 VAC under cold
start conditions will not exceed 37A.
Temperature Coefficient
0.03%/°C typical on all outputs.
Designed for 0 to 45°C operation at full rated output power; derate output
current and total output power by 2.5% per °C above 45°C.
Marked to LVD
6050 King Drive
Ventura CA, 93003
Phone:805.486.4565
Output Noise
Transient Response
Switching Frequency
Voltage Adjustment
EMI/EMC Compliance
Safety Approvals
SL Power Electronics, Corp. declares under our sole responsibility
MTBF
2 Year Warranty
Unless otherwise noted, all parameters are nominal values measured at 120 VAC @25˚C and 0-95%
relative humidity, non-condensing. For limits at unusual operatiing conditions, consult factory.
0.5% rms, 1% pk-pk typical (see chart), 20 MHz bandwidth, differential
mode. Measured with noise probe directly across output terminals of the
power supply with load terminated with 0.1 μF capacitor.
Main output—500 μs typical response time for return to within 0.5% of
final value for a 50% load step change. ∆i/ ∆t<0.2 A/μs. Maximum voltage
deviation is 3.5%. Startup/ shutdown overshoot less than 3%.
70 kHz +/-10 kHz.
Provided on V1. Adjustable voltages are preset at factory. Outputs are
capable of minimum +/- 5% change from nominal setting. Multiple output
models - V2 voltage will track V1 adjustment.
All models include built-in EMI filtering to meet the following emissions
requirements:
EMI SPECIFICATIONS
Conducted Emissions
Static Discharge
RF Field Susceptibility
Fast Transients/Bursts
Surge Susceptibility
that all GECA models are in conformity with the applicable requirements of
EN60950 following the provisions of the Low Voltage Directive 73/23/EEC.
All GECA models are approved to UL60950-1: 2003,
CSA-22.2 No. 60950-1-03, IEC and EN60950-1
120kHrs.
Fax:805.487.8911
Email:info@slpower.com
COMPLIANCE LEVEL
EN55022 Class B; FCC Class B
EN61000-4-2, Level 3
EN61000-4-3, Level 3
EN61000-4-4, Level 3
EN61000-4-5, Level 3
www.slpower.com

Related parts for GECA40HG

GECA40HG Summary of contents

Page 1

GECA40 40 Watt Series Commercial Wide-Range Input • Wide-Range AC Input 90-264 VAC • Industry Standard Footprint - 3”x 5”x 1.25” • Conducted EMI Exceeds FCC Class B and CISPR 22 Class B • Single and Multiple Outputs • Approved ...

Page 2

... GECA40 40 Watt Series Commercial Wide-Range Input Commercial Output Output Model No. (V) GECA40AG + -12 V GECA40BG +12V GECA40HG -12 V GECA40DG + -12 V GECA40- GECA40-12G GECA40-15G GECA40-24G Environmental Specifications ENVIRONMENT OPERATING Temperature ( 45°C Humidity ( 90% RH Shock ( Altitude -500 to 10,000 ft Vibration (C) 1.5 g 0.0032 g /Hz 2 rms’ ...

Related keywords