SCS405 TDK Corporation, SCS405 Datasheet

no-image

SCS405

Manufacturer Part Number
SCS405
Description
PWR SUP AC-DC 5.0V 8.0A
Manufacturer
TDK Corporation
Series
SC40r
Datasheets

Specifications of SCS405

Voltage - Output
5V
Number Of Outputs
1
Power (watts)
40W
Applications
Commercial
Power Supply Type
Switching (Open Frame)
Voltage - Input
85 ~ 265VAC
Mounting Type
Chassis Mount
1st Output
5 VDC @ 8A
Size / Dimension
5" L x 3" W x 1" H (127mm x 76.2mm x 25.4mm)
Power (watts) - Rated
40W
Operating Temperature
0°C ~ 70°C
Efficiency
70%
Approvals
CE, CSA, EN, IEC, UL
Line Regulation
±2%
Load Regulation
±2%
Brand/series
SC Series
Dimensions
5.00 in. L x 3.00 in. W x 0.12 in. T
Output
5 VDC @ 8 A
Power, Output
40 W
Primary Type
AC-DC
Standards
UL 60950-1, CSA 60950-1, IEC⁄EN60950-1, CE Mark Approval
Temperature, Operating, Maximum
+70 °C
Temperature, Operating, Minimum
0 °C
Voltage, Input
85 to 265 VAC
Voltage, Output
5 VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
RoHS Compliant part
Other names
285-1585
10 Inrush current -Typical (3)
11 Adjustment Range
12 Maximum Ripple & Noise (4)
13 Maximum Load regulation
14 Maximum Line regulation
15 Total Regulation
16 Temperature Co-efficient
17 Transient response
18 Overcurrent Protection (5)
19 Overvoltage Protection (6)
20 Hold up time - typical (7)
21 Operating Temperature (8)
22 Operating Humidity
23 Storage Temperature
24 EMI
25 Output - Ground isolation
26 Vibration
27 Shock
28 Safety
29 Other
30 Size
31 Terminals
32 Options
1 Nominal Output Voltage
2 Minimum Output Current
3
4
5 Maximum Peak Current (1)
6
7
8 Input Voltage Range
9 Efficiency (2) (Typical)
1 Notes:
2 Peak current lasting <30 seconds with 10% max duty cycle. Average power not to exceed rated maximum.
3 At 100VAC or 200VAC input and maximum output power
4 At 230VAC input cold start at 25C
5 Measured across 10uF electrolytic in parallel with 0.1uF ceramic on load cables 150mm from terminals of power supply
6 Avoid prolonged operation in overload
7 Cycle input to reset
SCS4x Series Specification
Rev 8 9/1/99
Specification
Maximum Output Current
convection cooled
Maximum Output Current
forced air cooled (300LFM)
Maximum Output Power
convection cooled
Maximum Output Power forced
air cooled (30 CFM)
Remote sense (2 pin Molex)
40W load at 115VAC nominal line
mV
mV
mV
ms
W
W
%
%
%
V
A
A
A
A
V
A
V
C
C
SCS40-3
26.4
36.3
+/-2
3.3
V1
11
12
0
8
127 x 76.2 x 25.4 (Max component height) component leads cropped 3mm max
SCS40-5
+/-2
10 - 55Hz Amplitude (sweep 1 min) Less than 2G X, Y, Z 1 hour ea
V1
11
12
40
55
Add "/R" to model number. Compensates for up to 0.25V per lead
5
0
8
LAMBDA SCSeries
UL1950, CSA 22.2 #950, EN60950, CE mark
FCC Class B Conducted, EN55022 class B
SCS40-12
39.6
+/-2
3.3
4.5
V1
12
54
0
5
Molex 09-50-80xx input & output
5 ~ 95% non condensing
Short circuit protection
85-265VAC, 47-63Hz
IEC801-2~6 level 3
Typically +/-0.02%
To be determined
1% peak to peak
SCS40-15
-5 ~ +10%
115-135%
-20 ~ 85C
500VDC
0 ~ 50C
Model
<20G
70%
+/-2
2.6
3.6
V1
15
39
54
36
20
0
4
SCS40-24
38.4
55.2
+/-2
1.6
2.3
2.5
V1
24
0
SCS40-28
39.2
+/-2
1.4
2.2
V1
28
56
0
2
SCS40-48
43.2
57.6
+/-2
0.9
1.2
1.3
V1
48
0
Rev 8

Related parts for SCS405

Related keywords