XS1 Excelsys Technologies Ltd, XS1 Datasheet - Page 12

BUS BAR SERIES

XS1

Manufacturer Part Number
XS1
Description
BUS BAR SERIES
Manufacturer
Excelsys Technologies Ltd
Series
powerModsr
Type
Bus Barr
Datasheet

Specifications of XS1

Accessory Type
Serial Output Link
For Use With/related Products
powerMods
For Use With
633-1020 - MODULE POWER DUAL 5VDC-28VDC 3A633-1019 - MODULE POWER 5VDC-28VDC 5A633-1018 - MODULE POWER 28VDC-58VDC 6A633-1017 - MODULE POWER 12VDC-30VDC 10A633-1016 - MODULE POWER 6VDC-15VDC 20A633-1015 - MODULE POWER 3.2VDC-6VDC 40A633-1014 - MODULE POWER 1.5VDC-3.6VDC 50A
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
633-1022

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
XS1-G02B-FB144-C4
Manufacturer:
XMOS
Quantity:
10 000
Part Number:
XS1-G02B-FB144-I4
Manufacturer:
XMOS
Quantity:
10 000
Part Number:
XS1-G04B-FB144-C4
Manufacturer:
XMOS
Quantity:
10 000
Part Number:
XS1-G04B-FB144-I4
Manufacturer:
XMOS
Quantity:
10 000
Part Number:
XS1-G04B-FB512-C4
Manufacturer:
XMOS
Quantity:
10 000
Part Number:
XS1-G2B-FB144
Manufacturer:
CRYSTAL
Quantity:
6
Part Number:
XS1-G4B-FB144
Manufacturer:
EPCOS
Quantity:
26
Part Number:
XS1-L01A-LQ64-C5
Manufacturer:
XMOS
Quantity:
20 000
Part Number:
XS1-L01A-TQ128-C5
Manufacturer:
XMOS
Quantity:
20 000
Part Number:
XS1-L02A-QF124-C5
Manufacturer:
XMOS
Quantity:
101
Part Number:
XS1-L02A-QF124-C5
Manufacturer:
XMOS
Quantity:
20 000
Company:
Part Number:
XS1-L02A-QF124-C5
Quantity:
8
2
SPECIFICATION
200W/400W/600W
NOTES
INPUT
Parameter
Input Voltage Range
Input Frequency Range
Power Rating XMA
Input Current XMA
Inrush Current
Undervoltage Lockout
Fusing
OUTPUT
Parameter
powerMod Power
Output Adjustment Range
Minimum Load
Line Regulation
Load Regulation
Cross Regulation
Transient Response
Ripple and Noise
Overvoltage Protection
Overcurrent Protection
Remote Sense
Overshoot
Turn-on Delay
Rise Time
Hold-up Time
Output Isolation
GENERAL
Parameter
Isolation Voltage
Efficiency
Safety Agency Approvals
Leakage Current
Signals
Bias Supply
Reliability
EMC
Parameter
Emissions
Conducted
Radiated
Harmonic Distortion
Flicker and Fluctuation
Immunity
Electrostatic Discharge
Radiated RFI
Fast Transients - burst
Input Line Surges
Conducted RFI
Voltage Dips
ENVIRONMENTAL
Parameter
Operating Temperature
Storage Temperature
Derating
Relative Humidity
Shock
Vibration
1. This product is not intended for use as a stand alone unit and must be installed by qualified personnel.
2. The specifications contained herein are believed to be correct at time of publication and are subject to change without notice.
3. All specifications at nominal input, full load, 25°C unless otherwise stated.
XMA
XMB
XMC
XMB
XMC
XMB
XMC
applies to configured units consisting of powerMods modules plugged into the appropriate powerPac
Conditions/Description
Universal Input
Derate linearly from 600W at 180VAC to 400W at 85VAC
85VAC in 200W out
85VAC in 400W out
85VAC in 400W out
230VAC @ 25°C
Shutdown
250V 5 x 20mm
250V 5 x 20mm
250V 5 x 20mm
Conditions/Description
As per powerMod table
Manual:
Electronic: See Xgen Designers’ Manual
For ±10% change from nominal line
For 25% to 75% load change
For 25% to 75% load change
20MHz Bandwidth
1st level: Vset Tracking. 2nd level: Vmax (Latching)
Straight line with hiccup activation at <30% of Vnom
See powerMod datasheet and Designer’s Manual for full details
Max. line drop compensation. (except Xg7, Xg8)
From AC In / Enable signal
Monotonic
For nominal output voltages at full load
Output to Output / Output to Chassis
Conditions/Description
Input to Output
Input to Chassis
230VAC, 400W @ 24V
EN60601-1, UL2601-1, CSA601-1 UL File No. E230761
250VAC, 60Hz, 25°C
See Xgen Series datasheet
Always ON. Current 250mA
Failures per million hours at 25°C and full load
See Designers’ Manual. powerPac excludes fans
Standard
EN55011, EN55022, FCC
EN55011, EN55022, FCC
EN61000-3-2
EN61000-3-3
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-11 (EN55024)
Conditions/Description
Full Load up to 50°C See derating below
2.5% per °C above 50°C
Non-condensing
3000 Bumps, 10G (16ms) half sine
1.5G
Slimline Medically Approved Power Supply
Multi-turn potentiometer. As per powerMod table
Europe/Asia
Excelsys Technologies Ltd
Swords Business Park
Swords, Co. Dublin
IRELAND
Voltage Deviation
Settling Time
t: +353 1 8900933
f: +353 1 8901358
e: sales@excelsys.com
powerMod
powerPac
North America
Excelsys Technologies
519 Interstate 30, #309
Rockwall, TX 75087
USA
Min
85
120
47
70
Min
110
110
20
500 / 500
Min
4000
1500
4.9
Min
-20
-40
5
10
Nom
4.0
7.5
7.5
F5A HRC
F8A HRC
F8A HRC
Nom
0
Nom
89
5.0
Level
Level B
Level B
Compliant
Compliant
Level 4
Level 3
Level 4
Class 4
10
10
Nom
t: (972) 771 4544
f: (972) 421 1805
e: salesusa@excelsys.com
Doc. 40040 rev. 02 04/05
Max
264
380
63
200
400
600
20
78
Max
±0.1
±0.2
±0.2
10
250
1.0
125
120
0.5
2
300 / 30
5
Max
300
5.1
1.0
0.5
Max
+70
+85
95
200
Units
VAC
VDC
Hz
W
W
W
A
A
A
A
VAC
Units
A
%
%
%
%
µs
% pk-pk
%
%
VDC
%
ms
ms
ms
VDC
Units
VAC
VAC
%
µA
VDC
fpmh
fpmh
Units
V/m
ms
Units
°C
°C
%RH
Hz