Main Purpose
Power Management, Battery Monitor, Car
Utilized Ic / Part
MAX11068
Primary Attributes
Monitors Current, Voltage, Temperature
Secondary Attributes
1 ~ 12 Cell- Li-Ion, 1 ~ 12 Cell- NiMH
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Embedded
-
Figure 3. Write to Register Controls
Figure 4. Read/Scan Tab Snapshot
A specific device in the SMBus ladder can be written to
by using the Write tab, Active_Register group box, and
Active_ Device drop-down list. To perform a write to a
specific register of a single device:
1) Select the device to be written to from the Active_
2) Select the register to be written to from the Active_
3) Enter the hex value (####) into the Data:_0x edit box
4) Press the Write_Active_Device button.
The Write tab can also be used to write an entered value
into the active register of all the devices in the SMBus
ladder. To perform a write to a specific register of all
devices:
Device_drop-down list or from the grid on the Device_
Addresses_(0x01) tab.
Register group box. The Active_Register label also
reflects the selected register.
in the Single_Device group box (Figure 3).
________________________________________________________________________________________ _ 9
Write Registers
MAX11068 Evaluation System
1) Select the register to be written to from the Active_
2) Enter the hex value (####) into the Data:_0x edit box
3) Press the_Write_All_Devices button.
When performing a read operation, all the devices in the
SMBus ladder are accessed. The read operation does
not allow only one device to be read. The register check-
boxes located on each register tab can be selected to
enable a read of the associated register. In addition,
each group of register checkboxes has an associated
ALL checkbox that, when checked/unchecked, selects/
deselects all the register checkboxes on that tab. The
select all and deselect all operations can also be exe-
cuted by selecting the Actions_|_Active_Tab_|_Select_All_
Ctrl+A or Actions_ |_ Active_ Tab_ |_ Select_ None_ Ctrl+N
menu item. The read operations are performed using the
controls on the Read/Scan tab or the keyboard short-
Register group box.
in the All_Devices group box.
Read Registers