G79-Y100C Omron, G79-Y100C Datasheet

no-image

G79-Y100C

Manufacturer Part Number
G79-Y100C
Description
CABLE HIGH DENSITY I/O 1M PLC
Manufacturer
Omron
Datasheet

Specifications of G79-Y100C

Accessory Type
Cable
For Use With/related Products
I/O Boards and PLC Modules
Color
-
Other names
G79Y100C
Q2101947A
Compact, 16-Point Output Blocks
Save Space in Control Panels
1
1
1
1
1
1
1
1
Ordering Information
3 RELAY OUTPUT BLOCKS
Relay Output Blocks
Compact standard version or
quick-to-service vertical models
Power MOSFET or relays installed
Built-in diode absorbs coil surge
All have operation indicators
Terminal blocks accept M3.5 fork-type
crimp terminals
Expansion terminal block for vertical
models allows power line connections
Mounts to DIN rail track or with screws
Dedicated cables for high-density PLC
modules available (sold separately)
Appearance
16 points
(SPST-NO x 16)
(SPST NO x 16)
includes relay
pulling tool.
16 points
(SPST-NO x 16)
9
Output points
g
24 VDC
24 VDC
voltage
Rated
Relay outputs
Power MOSFET
relay outputs
relay out uts
Relay outputs
Power MOSFET
relay outputs
Output type
NPN (+ common)
PNP (-- common)
NPN (+ common)
PNP (-- common)
NPN (+ common)
NPN (+ common)
circuit common
Internal I/O
Part number
G70D-SOC16 DC24
G70D-SOC16-1 DC24
G70D-FOM16
G70D-FOM16-1 DC24
G70D-VSOC16
G70D-VFOM16
G70D
èò

Related parts for G79-Y100C

G79-Y100C Summary of contents

Page 1

... Relay Output Blocks Compact, 16-Point Output Blocks Save Space in Control Panels 1 Compact standard version or quick-to-service vertical models 1 Power MOSFET or relays installed 1 Built-in diode absorbs coil surge 1 All have operation indicators 1 Terminal blocks accept M3.5 fork-type crimp terminals 1 Expansion terminal block for vertical ...

Page 2

... Rated voltage 24 VDC; minimum load VDC 24 VDC G70D Part number G79-Y100C G79-Y150C G79-Y200C G79-Y300C G79-Y500C G79-A200C G79-A500C Part number G79-100C G79-150C ...

Page 3

G70D Specifications 3 RATINGS The following values apply to the G6D Relay mounted to the G70D and do not apply to the G6D Relay itself before it is mounted. Electromechanical Relay (G6D) Specifications Coil Ratings Rated voltage 24 VDC Rated ...

Page 4

G70D 3 CHARACTERISTICS Part number G70D-VSOC16/ G70D-SOC16 (-1) Output type Relay outputs Contact form 16 points (SPST-NO x 16) Contact mechanism Single Contact resistance 100 m max. measured VDC Insulation method Must operate time 10 ms ...

Page 5

G70D Engineering Data 3 RELAY OUTPUT MODELS G70D-SOC16(-1)/G70D-VSOC16 Max. Switching Capacity DC resistive load AC resistive load Switching voltage (V) 3 POWER MOSFET OUTPUT MODELS G70D-FOM16(-1)/G70D-VFOM16 Load Current vs. Ambient Temperature Characteristics Ambient temperature ( C) Life Expectancy 250 VAC/30 ...

Page 6

... V 0 V..( V...(10)2 1(20)...24 V (Black triangle mark) Connector pin numbers in parentheses are for G79 Cable. Note: The pin numbers are indicated for user’s convenience. The black triangle mark can be used to determine orientation. 6 Note: Wiring shown above is for G6D Power Relays. ...

Page 7

... With Expansion Terminal Block Note: 1. The terminal block shows the G70D-VSOC16, which operates with G6D relays mounted. The G70D-VFOM16 terminal block uses G3DZ power MOSFET relays in place of G6D relays. 2. Terminals C0 to C15 are electrically independent from each other. 3. When the terminal block and relay block are connected to each other, each electrical check terminal of the relay block is connected to the corresponding terminal of the terminal block ...

Page 8

G70D G70D-VSOC16/VFOM16 Without Expansion Terminal Block 24 VDC G70D-VSOC16/VFOM16 With Expansion Terminal Block 24 VDC Connector 8 Electrical check terminals (See Note) Operation indicators Note: When the terminal block and relay block are connected to each other, each electrical check ...

Page 9

G70D Dimensions Unit: mm (inch) G70D-SOC16(-1) G70D-FOM16(- 0.2 (2.12) (1.57 0.008) 51 (2.01) max. Mounting Holes Two, 4.2 dia 0.2 (1.57 0.008) G70D-VSOC16 G70D-VFOM16 50 0.2 (1.97 0.008) Terminal Block (without Expansion Terminal Block) 135 ...

Page 10

... G79-YPC Cable with Crimp Terminals Convenient for connecting screw terminals to Output Blocks G79-APC Cable with Loose Wires Device connection end provides loose wires. With loose wires and crimp terminals Length (ç) 1,000 mm (3.28 ft) G79-Y100C 1,500 mm (4.92 ft) G79-Y150C 2,000 mm (6.56 ft) G79-Y200C 3,000 mm (9.84 ft) G79-Y300C 5,000 mm (16 ...

Page 11

... G70D G79-OPC-P Cable with Connector (1:2) Applicable Omron PLC pp High-density I/O Modules I Part number No. of output points C200H-OD218 32 points (1 cable) ( C200H-OD219 C200H OD219 64 points (2 cables C500-OD213 C500-OD213 64 points (2 cables) 64 points (2 cables) CQM1 OD213 CQM1-OD213 32 points (1 cable) 32 oints (1 cable) G79-PC-P-P Cable with Connector (1:3) ...

Page 12

... G70D 3 ACCESSORIES Unit: mm (inch) These accessories are for G70D-VSOC16 and G70D-VFOM16 Terminal Blocks. G70D-ET Expansion Terminal Block G6D-4-SB Short Bar Precautions 3 GENERAL PRECAUTIONS The G70D is used only for outputs. Electric Shock It is extremely dangerous to connect or disconnect relays with the power turned on. Always turn off the power before wiring the Output Block or replacing the relays ...

Page 13

... Output Block. The relay block has operation indicators and replaceable Relays along with electrical check terminals for monitoring the operation of the Output Block. The Expansion Terminal Block can be mounted to the Output Block for power line connections ...

Page 14

G70D Nameplate of Terminal Block As shown in Figure 1, the nameplate of the terminal block is located on the bottom surface of the relay block. To fill in the nameplate, remove the nameplate from the relay block. Then return ...

Page 15

... G70D NOTE: DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches divide by 25.4. 9 OMRON ELECTRONICS, INC. One East Commerce Drive Schaumburg, IL 60173 1-800-55-OMRON Cat. No. GC RIO-1 04/00 Specifications subject to change without notice. G70D OMRON CANADA, INC. 885 Milner Avenue Scarborough, Ontario M1B 5V8 416-286-6465 Printed in U ...

Related keywords