G2R-2-SND DC24(S) Omron, G2R-2-SND DC24(S) Datasheet - Page 4

RELAY PWR DPDT 5A 24VDC PLG

G2R-2-SND DC24(S)

Manufacturer Part Number
G2R-2-SND DC24(S)
Description
RELAY PWR DPDT 5A 24VDC PLG
Manufacturer
Omron
Series
G2RSr
Datasheets

Specifications of G2R-2-SND DC24(S)

Relay Type
General Purpose
Contact Form
DPDT (2 Form C)
Contact Rating (current)
5A
Switching Voltage
380VAC, 125VDC - Max
Coil Type
Standard
Coil Current
21.6mA
Coil Voltage
24VDC
Turn On Voltage (max)
16.8 VDC
Turn Off Voltage (min)
3.6 VDC
Mounting Type
Socket
Termination Style
Socketable
Circuit
DPDT (2 Form C)
Contact Rating @ Voltage
5A @ 250VAC
Control On Voltage (max)
16.8 VDC
Control Off Voltage (min)
3.6 VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
G2R-2-SNDDC24(S)
G2R-2-SNDDC24(S)
G2R2SNDDC24S
Z2866
Engineering Data
■ Maximum Switching Capacity
Plug-in Relays
■ Electrical Service Life
Plug-in Relays
Ambient Temperature vs. Maximum Coil Voltage
248
G2R-1-S
G2R-1-S
100
0.1
5,000
1,000
10
1
500
100
1
50
DC inductive load
(L/R = 7 ms)
30-VDC inductive load (L/R = 7ms)
DC resistive
load
Ambient temperature (°C)
AC coil
General-purpose Relay
AC inductive load
(cosφ = 0.4)
Switching current (A)
Switching voltage (V)
10
250-VAC/30-VDC
resistive load
250-VAC inductive load
(cosφ = 0.4)
DC coil
100
AC resistive
load
1000
G2RS-(S)
10,000
5,000
1,000
100
0.1
G2R-2-S
10
500
100
1
50
G2R-2-S
1
Note: The maximum voltage refers to the maximum
250-VAC
inductive load
(cosφ = 0.4)
DC inductive load
(L/R = 7 ms)
Switching current (A)
AC inductive load
(cosφ = 0.4)
DC resistive
load
value in a varying range of operating power
voltage, not a continuous voltage.
Switching voltage (V)
30-VDC inductive load (L/R = 7ms)
10
250-VAC/30-VDC
resistive load
100
AC resistive
load
1000

Related parts for G2R-2-SND DC24(S)