RELAY PWR DPDT CO 30A 240VAC QC

T92S11A22-240

Manufacturer Part NumberT92S11A22-240
DescriptionRELAY PWR DPDT CO 30A 240VAC QC
ManufacturerTyco Electronics
SeriesT92
T92S11A22-240 datasheets
 


Specifications of T92S11A22-240

Relay TypeGeneral PurposeContact FormDPDT (2 Form C)
Contact Rating (current)30ASwitching Voltage240VAC
Coil TypeStandardCoil Current16.7mA
Coil Voltage240VACTurn On Voltage (max)192 VAC
Turn Off Voltage (min)24 VACMounting TypeChassis Mount
Termination StyleQuick Connect - .250" (6.3mm)CircuitDPDT (2 Form C)
Contact Rating @ Voltage30A @ 240VACControl On Voltage (max)192 VAC
Control Off Voltage (min)24 VACCoil Voltage Vac Nom240V
Contact Current Max30AContact Voltage Ac Nom600V
Contact Voltage Dc Nom28VCoil Resistance3800ohm
Contact ConfigurationDPDTContact Rating30 A
Coil TerminationQuick ConnectContact TerminationTerminals
Mounting StylePlug-inPower Consumption4 VA
Contact MaterialSilver Cadmium OxideLead Free Status / RoHS StatusLead free / RoHS Compliant
Other names8-1393211-7
PB737
  
1
Page 1
2
Page 2
3
Page 3
Page 1/3

Download datasheet (253Kb)Embed
Next
Features
• 30A DPST-NO and DPDT switching capabilities.
• Designed to control compressor loads to 3.5 tons, 25.3 FLA, 110 LRA.
• Extended life – >300,000 operations at 30A, 240VAC (DC coil).
>100,000 operations at 30A, 240VAC (AC coil).
• Meets requirements of UL873 and UL508 spacings.
– .315” (8mm) through air, .375” (9.5mm) over surface.
• Meets requirements of VDE 8mm spacing, 4kV dielectric coil-to-contacts.
• Meets requirements of UL Class F construction.
• UL approved for 600VAC switching (1.5HP).
• Conforms to VDE 0435, 0631, and 0700.
• New screw terminal version.
Contact Ratings @ 25°C with relay properly vented.
Remove tape over vent hole after soldering and cleaning.
Arrangements: 2 Form A (DPST-NO) and 2 Form C (DPDT).
Materials: Silver cadmium oxide and silver tin indium oxide.
Max. Load Rating, Silver Cadmium Oxide Contacts:
Normally Open Contacts:
40A @ 277VAC, resistive; 6K Ops. (Flange Mount);
30A @ 120/277VAC, resistive;
10A @ 600VAC, resistive;
1 HP @ 120VAC, 3 HP @ 240VAC;1.5 HP @ 480VAC, 1.5 HP @ 600VAC
110 LRA, 25.3 FLA, @ 240VAC with DC coil
;
(1)
60 LRA, 14 FLA @ 240VAC with AC coil;
3A @ 240VAC pilot duty;
20A @ 28VDC;
TV10 @ 120VAC.
VDE Rating (Flange Mount): 20A @ 400VAC, 100K Ops. (30K Ops. for
Form C Models).
VDE Rating (PC Mount): 30A @ 400VAC, 100K Ops. (30K Ops. for
Form C Models).
Normally Closed Contacts:
3A @ 28VDC or 277VAC, 2A @ 480VAC, 1A @ 600VAC.
VDE Rating (Flange or PC Mount): 3A @ 400VAC, 30K Ops.
Max. Load Rating, Silver Tin Indium Oxide Contacts
Normally Open Contacts Only:
30A @ 120/277VAC, resistive; 200K Ops., DC Coil; 100K Ops, AC Coil
20A @ 480VAC, resistive;
1.5 HP @ 120VAC, 2 poles making/breaking (see Fig. 1)
3 HP @ 240VAC, 3 phase, DC coil only;
3 HP @ 480VAC, 3 phase, DC coil only;
2 HP @ 600VAC, 3 phase, DC coil only.
Min. Load Rating:
Normally Open Contacts: 500mA @ 12VAC/VDC.
Normally Closed Contacts: 100mA @ 6VAC/VDC.
Expected Mechanical Life: 5 million operations.
Expected Electrical Life: 100,000 operations at rated load, except as
specifically noted otherwise.
Dimensions are shown for refer-
Dimensions are in inches over
ence purposes only.
(millimeters) unless otherwise
specified.
Catalog 1308242
Issued 3-03 (PDF Rev. 8-07)
T92
series
Two-Pole, 30 Amp
PC Board or Panel Mount Relay
File E22575
File LR15734
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that user also seek out the pertinent approvals files
of the agencies/laboratories and review them to ensure the product meets the
requirements for a given application.
Contact Ratings (continued)
ARI 780-86 Endurance Test (section 6.6):
HVAC Definite Purpose Contactor Standard
Normally Open Contacts
Single Phase/Two Pole (Both poles together switching a single load)
110 LRA, 25.3 FLA, 200K operations (DC Coil)
L1
L2
Figure 1
T1
Single Phase Per Pole (Single load per pole)
110 LRA, 18 FLA, 200K operations (DC Coil).
60 LRA, 14 FLA, 200K operations (AC Coil).
L1
T1
Figure 2
Notes: Vent hole tape must be removed to achieve all listed ratings.
Initial Dielectric Strength
Between Contacts and Coil: 4,000V rms, 50/60 Hz.
Between Open Contacts: 1,500V rms, 50/60 Hz.
Between Poles: 2,000V rms, 50/60 Hz.
Initial Insulation Resistance
Between Mutually Insulated Elements: 10
Coil Data
Voltage: 12 through 110VDC and 12 through 277VAC.
Resistance: See Coil Data table.
Nom. Power: AC Coil: 4.0VA; DC Coil: 1.7W.
Coil Temp. Rise: 35°C/W.
Max. Coil Temp.: 155°C.
Duty Cycle: Continuous.
Coil Data (@ 25°C Coil Temperature)
Nom. Voltage
DC Resist.
( VDC )
±10% ( Ohms )
12
86
24
350
AC Coils ( 4.0VA )
Nom. Voltage
Freq.
DC Resist.
( VAC )
±10% ( Ohms )
12
60
9.1
24
60
36.6
Notes
(1) FLA, LRA ratings are compatible with 3.5 ton compressor applications.
(2) Nominal voltage, no coil suppression, excluding bounce.
Specifications and availability
subject to change.
P&B
File E22575 (type 2,3,4,5)
File No. 5386 (type 1,2,3,4)
T2
L2
T2
9
ohms, min. @ 500VDC.
DC Coils ( 1.7W )
Nom. Voltage
DC Resist.
( VDC )
±10% ( Ohms )
48
1,390
110
7 ,255
Nom. Voltage
Freq.
DC Resist.
( VAC )
±10% ( Ohms )
110/120
50/60
950
200/208
50/60
2,841
220/240
50/60
3,800
250/277
50/60
5,485
www.tycoelectronics.com
Technical support:
511
Refer to inside back cover.

T92S11A22-240 Summary of contents

  • Page 1

    Features • 30A DPST-NO and DPDT switching capabilities. • Designed to control compressor loads to 3.5 tons, 25.3 FLA, 110 LRA. • Extended life – >300,000 operations at 30A, 240VAC (DC coil). >100,000 operations at 30A, 240VAC (AC coil). • ...

  • Page 2

    Ambient Temperature vs. Coil Voltage 120 100 100 105 110 115 120 125 130 135 140 145 150 Applied Coil Voltage (% of Rated Nominal) Assumptions: 1. Thermal resistance ...

  • Page 3

    Outline Dimensions Mounting & Termination Type 1 2.06 MAX. (52.32) 1.21 MAX. (30.73) .156 (3.96) 1.618 ± .020 (41.10 ± .51) .585 ± .005 (14.86 ± .13) .032 TYP. .309 ± .005 (0.81) (7.85 ± .13) 1.000 ± .010 .630 ...