RELAY AUTO SPDT 40A 24VDC .25QC

VF4A-15H11

Manufacturer Part NumberVF4A-15H11
DescriptionRELAY AUTO SPDT 40A 24VDC .25QC
ManufacturerTyco Electronics
SeriesVF4
VF4A-15H11 datasheet
 


Specifications of VF4A-15H11

Relay TypeAutomotiveContact FormSPDT (1 Form C)
Contact Rating (current)40ASwitching Voltage12VDC
Coil TypeStandardCoil Current66.7mA
Coil Voltage24VDCTurn On Voltage (max)14.4 VDC
Turn Off Voltage (min)2.4 VDCMounting TypeSocket
Termination StyleQuick Connect - .250" (6.3mm)CircuitSPDT (1 Form C)
Contact Rating @ Voltage40A @ 12VDCControl On Voltage (max)14.4 VDC
Control Off Voltage (min)2.4 VDCLead Free Status / RoHS StatusLead free / RoHS Compliant
Other names8-1393298-1
PB215
  
1
Page 1
2
Page 2
3
Page 3
4
Page 4
5
Page 5
6
Page 6
7
Page 7
Page 1/7

Download datasheet (569Kb)Embed
Next
Plug-In Relays
Mini ISO Relays
VF4 A (Standard, Shrouded and Weatherproof)
Features
– Limiting continuous
current 40 A
– Pin assignment according
to ISO 7588 part 1
– Plug-in terminals
Customized Versions
on Request
– Integrated components
(e.g. resistor, diode)
– Customized marking
– Special covers
(e.g. brackets, shrouded)
– For latching (bistable) version
refer to Mini Relay Latching
Typical Applications
Cross carline up to 40 A
for example:
– ABS control
– Blower fans
– Car alarm
– Cooling fan
– Electric Power Steering
– Energy management
– Engine control
– Fuel pump
– Heated front screen
– Ignition
– Immobilizer
– Lamps front, rear, fog light
– Main switch/supply relay
– Seatbelt pretensioner
Design
– Trunk lock
– ELV compliant
– Valves
– Dustproof; protection class IP54
– Window lifter
to IEC 529 (EN 60 529)
– Wiper control
– Sealed: protection class IP67 to
IEC 529 (EN 60 529)
Please contact Tyco Electronics
– Shrouded: protection class IP67 to
for relay application support.
IEC 529 (EN 60 529) if used with
special connector
Weight
Approx. 35 g (1.2 oz.)
Nominal Voltage
12 V or 24 V
Disclaimer
All technical performance data apply to the relay as such, specific conditions of the individual application are not considered. Please always check the suitability of the
relay for your intended purpose. We do not assume any responsibility or liability for not complying herewith. We recommend to complete our questionnaire and to request
our technical service. Any responsibility for the application of the product remains with the customer only. All specifications are subject to change without notification.
All rights of Tyco Electronics are reserved.
64
All specifications subject to change. Consult Tyco Electronics for latest specifications.
Terminals
Conditions
Quick connect terminals similar to
All parametric, environmental and
ISO 8092-1, coil and load 6.3 x 0.8 mm;
endurance tests are performed
surfaces tin plated
according to EIA Standard RS-407-A
at standard test conditions unless
Accessories
otherwise noted:
Connectors see page 233 ff
23°C ambient temperature,
20 - 50% RH, 998.9 ±33.9 hPa.
For general storage and processing
recommendations please refer to our
Application Notes and especially to
Storage in the “Glossary” page 23 or
at http://relays.tycoelectronics.com/
appnotes/
Catalog 1308028-2
Revised 3-2008
VF4_3D1

VF4A-15H11 Summary of contents

  • Page 1

    ... Any responsibility for the application of the product remains with the customer only. All specifications are subject to change without notification. All rights of Tyco Electronics are reserved. 64 All specifications subject to change. Consult Tyco Electronics for latest specifications. Terminals Conditions Quick connect terminals similar to All parametric, environmental and ISO 8092-1, coil and load 6.3 x 0.8 mm ...

  • Page 2

    ... MAX. 4.25 6.3 TYP. 25.0 MAX. 32.0 MAX. 17.9 8.4 8.0 4.5 16.8 All specifications subject to change. Consult Tyco Electronics for latest specifications. View of the Terminals (bottom view) Terminal thickness 5.0 0.81 + 0.03 28.0 MAX. 30 16.8 85 6.3 TE1344-I2 View of the Terminals (bottom view) 7 ...

  • Page 3

    ... MAX. View of the Terminals (bottom view 87a 8 8.0 16.8 12.0 ±0.38 66 All specifications subject to change. Consult Tyco Electronics for latest specifications. 4.20 ±0.15 7.5 ±0.45 19.7 ±0.15 36.1 MAX. 17.9 Catalog 1308028-2 11.50 ±0.15 7.0 REF. TE1348-91 Revised 3-2008 ...

  • Page 4

    ... For a load current duration of maximum 3 s for a make/break ratio of 1:10. 3) See chapter Diagnostics of Relays in our Application Notes page 31 or consult the internet at http://relays.tycoelectronics.com/appnotes/ Load Limit Curve All specifications subject to change. Consult Tyco Electronics for latest specifications. 1 Changeover contact/ 1 Form 20/14 A ...

  • Page 5

    ... Note: A low resistive suppression device in parallel to the relay coil increases the release time and reduces the lifetime caused by increased erosion and/or higher risk of contact tack welding. Operating Voltage Range 68 All specifications subject to change. Consult Tyco Electronics for latest specifications 87a ...

  • Page 6

    ... Current and time are compatible with circuit protection by a typical 40 A automotive fuse. Relay will make, carry and break the specified current. All specifications subject to change. Consult Tyco Electronics for latest specifications. Protects relay from dust. For use in passenger compartment or enclosures Protects relay and relay connector (order separately) from dust and splash Mates with a connector (order separately) to seal relay from salt spray etc ...

  • Page 7

    ... VF4-1: 357 pieces VF4-2, VF4-3: 165 pieces VF4-4: 136 pieces VF4-5, VF4-6: 110 pieces 70 All specifications subject to change. Consult Tyco Electronics for latest specifications. Circuit/Contact Contact Arrangement Material C0/1 Form C AgNi0.15 CR/1 Form C AgNi0.15 CR/1 Form C AgNi0.15 ...