PBC-009A1E7 Tyco Electronics, PBC-009A1E7 Datasheet

no-image

PBC-009A1E7

Manufacturer Part Number
PBC-009A1E7
Description
RELAY CONTACTOR IEC 9A 1NC 48V
Manufacturer
Tyco Electronics
Series
PBCr
Datasheets

Specifications of PBC-009A1E7

Mounting Type
DIN Rail
Relay Type
Contactor
Contact Form
3PST-NO-DM (3 Form X)
Contact Rating (current)
8A
Switching Voltage
380VAC
Coil Type
Standard
Coil Voltage
48VAC
Turn On Voltage (max)
40.8 VAC
Turn Off Voltage (min)
9.6 VAC
Termination Style
Screw Terminal
Circuit
3PST-NO-DM (3 Form X)
Contact Rating @ Voltage
8A @ 380VAC
Control On Voltage (max)
40.8 VAC
Control Off Voltage (min)
9.6 VAC
No. Of Poles
3
Contact Configuration
3PST-NO
Relay Mounting
DIN Rail / Panel
Coil Voltage Vac Nom
48V
Nom Operating Power
9.4VA
Contact Voltage Ac Nom
380V
Contact Current Max
9A
Contact Termination
Screw Clamps
Mounting Style
Chassis
Contact Material
Copper Silver Nickel
Contact Rating
9 A, 25 A
Coil Termination
Screw Clamp
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Coil Current
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
1672273-3
Electrical Life
RoHS
Ready
Features
Main Contact Data
Arrangements: 3 Form X (3PST-NO-DM).
Ratings: Insulation Voltage (U i ): 690V
Auxiliary Contact Data
Arrangements: 1 Form A (SPST-NO), 1 Form B (SPST-NC) or 1 Form A + 1
Form B (SPST-NO + SPST-NC).
Ratings: Insulation Voltage (U i ): 690V.
Initial Dielectric Strength
Between Contacts and Coil: 2,500V for 1 minute.
Between Open Contacts: 2,500V for 1 minute.
Between Poles: 2,500V for 1 minute.
Main Contact Ratings
Issued 4-08
www.tycoelectronics.com
• Three pole switching (main contacts) plus integral auxiliary contacts.
• Designed to snap onto DIN rail or mount directly to a panel wth screws.
• Efficient 50/60 Hz coils (50 Hz or 60 Hz coils optional).
• Finger-safe (IP 20) terminals.
• Modular design allows contactors and accessories to snap together.
• Comply with IEC EN60947-4-1 & EN60947-5-1; UL508; CSA22.2 No. 14.
Contactor
Rating
Code
009
012
018
025
032
040
050
065
080
Rating
Code
009
012
018
025
032
040
050
065
080
See Main Contact Ratings table below.
Cu-AgNi 90/10
Cu-AgNi 90/10
AC-15: 360VA.
DC-13: 33W.
Conventional Thermal Current (I th ): 10A.
Material
AgCdO12
AgCdO12
AgCdO12
AgCdO12
AgCdO12
AgCdO12
Contact
AgNi
1,000,000
1,000,000
1,000,000
1,000,000
800,000
800,000
600,000
600,000
600,000
Cycles
AC-3 (6I e , I e )
380VAC 660VAC
12
18
25
32
40
50
65
80
Cycles/Hr
9
Inductive
Amp (I e )
1200
1200
1200
1200
Maximum Currrent
600
600
600
600
600
AC3
Dimensions are in inches over
(millimeters) unless otherwise
specified.
6.6
8.9
12
18
21
34
39
42
49
Rated Operating
380V
Current (I e A)
P&B PBC Series IEC Type Contactors & Accessories
18.5
3.5
7.7
8.5
12
24
28
37
5
Amp (I th )
Resistive
690VAC
AC1
125
25
25
32
40
50
60
80
80
660V
17.3
1.5
3.8
4.4
7.5
12
14
2
9
AC-4 (6I e , I e )
115VAC 230VAC 220VAC 380VAC 440VAC 600VAC 220VAC 415VAC 440VAC 600VAC 220VAC 380VAC 415VAC 440VAC 660VAC
0.5
7.5
1
1
2
2
3
3
5
200,000
200,000
200,000
200,000
200,000
150,000
150,000
150,000
100,000
Single
Phase
Cycles
7.5
10
15
15
1
2
3
3
5
Dimensions are shown for reference
purposes only. Specifications and
availability subject to change.
Maximum Horsepower
Cycles/hr
300
300
150
150
150
150
150
150
150
7.5
10
15
20
25
30
3
5
5
7.5
10
10
15
25
30
40
50
5
Phase
Three
7.5
10
15
20
30
40
50
60
5
Coil Data
PBC
IEC-Type Contactors & Accessories
9-80 Amp AC-3, 25-125 Amp AC-1
AC Coils
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that users also seek out the pertinent approval files of
the agencies/laboratories and review them to confirm the product meets the
requirements for a given application.
Coil Data
Voltage: From 24 to 415VAC. See Ordering Information chart for specifics.
Must-Operate Voltage: 85 to 110% of nominal (U s ).
Must-Release Voltage: 20 to 75% of nominal (U s ).
Environmental Data
Temperature Range:
Maximum Altitude: 2000m
Pollution Class: 3
Vibration: 2-13.2 Hz, ±1mm
Shock Resistance: 13.2-100 Hz, ±7m/s 2
Short Circuit
Contactor
Rating Code
Type of Coord.
Main Circuit
Main Circuit
Fuse Type
Aux. Circuit
Fuse Type
Short Circuit
Current A
Aux. Circuit
Operating: –5°C to +40°C at RH or 50% or less. Higher humidity is
Storage:
Contactor
Rating
Code
7.5
009
012
018
025
032
040
050
065
080
10
10
20
25
40
50
60
75
File E38802 (PBC)
15.2
15.2
9.6
22
28
42
54
68
80
series
permissible at lower temperatures.
–25°C to +55°C
USA: 1-800-522-6752
Canada: 1-905-470-4425
Mexico: 01-800-733-8926
C. America: 52-55-1106-0803
RT16- RT16- RT16- RT16- RT16- RT16- RT16- RT16- RT16-
380-
009
Three Phase
Inrush
9.7
16
14
18
18
27
44
54
66
83
110
110
230
230
230
230
80
80
80
FLA
Maximum VA
012
20
7.6
11
14
21
27
40
54
65
77
018
25
11
17
22
27
41
54
62
77
9
Sealed
9.4
9.4
9.4
11
11
32
32
32
32
025
32
18.5
2.2
5.5
7.5
11
15
22
3
4
Type “2”
RT16-10
1,000
032
50
18.5
5.5
7.5
11
15
22
30
37
4
South America: 55-11-2103-6000
Hong Kong: 852-2735-1628
Japan: 81-44-844-8013
UK: 44-8706-080208
Operate
040
Control Power
63
12-22
12-22
12-22
15-24
15-24
20-26
20-26
20-26
20-35
Release Times (ms)
Operate &
kW
5.5
11
15
22
25
37
45
4
9
050
63
5.5
11
15
22
30
37
45
065
4
9
80
Release
4-12
4-12
4-12
5-19
5-19
8-12
8-12
8-12
6-20
18.5
080
100
5.5
7.5
10
15
30
33
37
45
1

Related parts for PBC-009A1E7

PBC-009A1E7 Summary of contents

Page 1

... P&B PBC Series IEC Type Contactors & Accessories RoHS Ready Features • Three pole switching (main contacts) plus integral auxiliary contacts. • Designed to snap onto DIN rail or mount directly to a panel wth screws. • Efficient 50/60 Hz coils ( coils optional). • Finger-safe (IP 20) terminals. ...

Page 2

... Hz / 120VAC 60 Hz (40 -80A models only) = 380VAC 415VAC 60 Hz PBC-018 is still to be submitted for UL testing. This model is not UL Listed. USA: 1-800-522-6752 South America: 55-11-2103-6000 Hong Kong: 852-2735-1628 Canada: 1-905-470-4425 Japan: 81-44-844-8013 Mexico: 01-800-733-8926 UK: 44-8706-080208 C ...

Page 3

... P&B PBC Series IEC Type Contactors & Accessories Outline Dimensions 3.23 MAX. (82) 2.99 MAX. (76) 1.38 (35) PBC-009 & PBC-012 3.82 MAX. (97) 3.39 MAX. (86) 1.38 (35) PBC-025 4.57 MAX. (116) 5.04 MAX. (128) 2.95 (75) PBC-040, PBC-050 & PBC-065 Mounting Dimensions 2 x .178 DIA (4.5) 2 ...

Page 4

... P&B PBC Series IEC Type Contactors & Accessories Features • & auxiliary contacts • Manual/automatic reset • Trip indicator • Stop button • Test function • Tamper resistant cover • Mounts directly on contactor Auxiliary Contact Data Arrangements: 1 Form Form B (SPST-NO + SPST-NC). ...

Page 5

... P&B PBC Series IEC Type Contactors & Accessories Ordering Information 1. Type: PBO = Bimetallic Thermal Overload Relay for use with PBC series IEC Contactors 2. Contactor Size For Which Overload Relay is Designed (AC-3 Main Contact Rating of Contactor 9-32A 12 = 12-32A 18 = 18-32A 40 = 40-80A 50 = 50-80A 65 = 65-80A 3 ...

Page 6

... P&B PBC Series IEC Type Contactors & Accessories Features • One, two and four pole models • Snap mount directly to front or side of contactor. Auxiliary Contact Data Arrangements: 1 Form A (SPST-NO), 1 Form B (SPST-NC), 1 Form Form B (SPST-NO + SPST-NC), 2 Form A (DPST-NO), 2 Form B (DPST-NC), 2 Form Form B (DPST-NO + DPST-NC), 4 Form A (4PST-NO), 4 Form B (4PST-NC), 3 Form Form B (3PST-NO + SPST-NC) ...

Page 7

... PBA-04A PBT NOTE: PBC contactors of different sizes will physically accommodate varying numbers of auxiliary contact blocks; however, no more than two blocks of auxiliary contacts (timed or non-timed) should be used with any PBC contactor at a given time. Issued 4-08 Dimensions are in inches over www.tycoelectronics.com (millimeters) unless otherwise specified ...

Page 8

... Part Number Auxiliary Contact Sets PBT-220 PBT-222 PBT-224 PBT-320 PBT-322 PBT-324 NOTE: All PBT models may be used with any PBC series contactor. All models are RoHS compliant. Mounting Diagrams (45) 1.97 MAX (50) Dimensions are shown for reference purposes only. Specifications and availability subject to change. ...

Related keywords