DK1A-5V-F Panasonic Electric Works, DK1A-5V-F Datasheet - Page 3

RELAY PWR SPST-NO 10A 5VDC PCB

DK1A-5V-F

Manufacturer Part Number
DK1A-5V-F
Description
RELAY PWR SPST-NO 10A 5VDC PCB
Manufacturer
Panasonic Electric Works
Series
DKr
Type
Power Relayr
Datasheets

Specifications of DK1A-5V-F

Relay Type
General Purpose
Contact Form
SPST-NO (1 Form A)
Contact Rating (current)
10A
Switching Voltage
250VAC
Coil Type
Standard
Coil Current
40mA
Coil Voltage
5VDC
Turn On Voltage (max)
3.5 VDC
Turn Off Voltage (min)
0.5 VDC
Mounting Type
Through Hole
Termination Style
PC Pin
Circuit
SPST-NO (1 Form A)
Contact Rating @ Voltage
10A @ 250VAC
Control On Voltage (max)
3.5 VDC
Control Off Voltage (min)
0.5 VDC
Brand/series
DK Series
Current, Rating
10 A
Function
Power
Latch Type
Single Side Stable
Number Of Pins
4
Power, Rating
2500⁄300 VA⁄W
Standards
UL, CSA, VDE, TUV
Termination
Solder
Voltage, Control
5 VDC
Voltage, Rating
380 VAC
Relay Construction
Non-Latching
Contact Arrangement
SPST-NO
Coil Voltage Dc
5V
Voltage Rating (vdc)
125V
Voltage Rating (vac)
250V
Dropout Volt (min)
0.5VDCV
Coil Resistance
125Ohm
Pick-up Voltage (max)
3.5VDC
Maximum Power Rating
300W/2.5KVA
Operate Time
10ms
Contact Current Rating
10A
Coil Suppression Diode
No
Push To Test Button
No
Led Indicator
No
Seal
Sealed
Product Height (mm)
10mm
Product Depth (mm)
12.5mm
Product Length (mm)
20mm
Operating Temp Range
-40C to 65C
Pin Count
4
Mounting Style
Through Hole
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
255-2058
DK1A-5V-F

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DK1A-5V-F
Manufacturer:
Panasonic Electric Works
Quantity:
1 994
Part Number:
DK1A-5V-F
Quantity:
5 400
DK
2. Specifications
Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
REFERENCE DATA
1-(1). Maximum operating power (1 Form A)
2-(2). Life curve
(1 Form A 1 Form B, 2 Form A)
Contact
Rating
Electrical
characteristics
Mechanical
characteristics
Expected life
Conditions
Unit weight
Characteristics
1,000
100
100
0.1
10
10
*2. Wave is standard shock voltage of 1.2 50 s according to JEC-212-1981
*3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
1
1
0
250 V AC inductive load (cos = 0.4)
30 V DC inductive load (L/R = 7 ms)
actual load.
conditions in NOTES.
DC inductive load
1
AC inductive load
2
(L/R = 7 ms)
(cos = 0.4)
3
10
Arrangement
Contact resistance (Initial)
Contact material
Nominal switching capacity (resistive load)
Max. switching power (resistive load)
Max. switching voltage
Max. switching current
Nominal operating power
Min. switching capacity (Reference value)*
Insulation resistance (Initial)
Breakdown voltage
(Initial)
Surge breakdown
voltage*
Temperature rise (coil) (at 65 C
Operate time [Set time] (at 20 C
Release time [Reset time] (at 20 C
Shock resistance
Vibration resistance
Mechanical
Electrical
Conditions for operation, transport and storage*
Max. operating speed (at rated load)
Contact voltage, V
Contact current, A
4
250 V AC resistive load
30 V DC resistive load
5
6
AC resistive load
2
100
(Initial)
DC resistive
load
7
8
9 10
1,000
Between open contacts
Between contact and coil
between contacts and coil
Functional
Destructive
Functional
Destructive
Item
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
149
68
68
1-(2). Maximum operating power
(1 Form A 1 Form B, 2 Form A)
3-(1). Operate/Release time (1 Form A)
Tested sample: DK1a-24V, 5 pcs.
F)
F)
F)
0.1
10
1
5
1
9
8
7
6
5
4
3
2
1
0
80
DC inductive load
3
AC inductive load
90
(L/R = 7 ms)
Release time
(with diode)
Operate time
Release time
10 A 250 V AC, 10 A 30 V DC
Min. 1,000M (at 500V DC) Measurement at same location as “Breakdown voltage” section.
Max. 40 C (By resistive method, nominal voltage applied to the coil; max. switching current)
(cos = 0.4)
10
(Nominal coil voltage applied to the coil, excluding contact bounce time.) (without diode)
Coil applied voltage,%V
Au-flashed AgSnO
10
Contact voltage, V
250 V AC, 125 V DC
Approx. 5 g
2,500VA, 300 W
110
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Min. 98 m/s
(Nominal coil voltage applied to the coil, excluding contact bounce time.)
1 Form A
AC resistive load
10 A
DC resistive
10 to 55 Hz at double amplitude of 1.5 mm (Detection time: 10 s.)
100
120
load
Max.
Max.
x
Min.
Min.
Max.
Min.
x
x
Min. 10
.18 oz
Ambient temperature: –40 C to +65 C
130
Min. 980 m/s
Max. 10 ms (Approx. 5 ms) [10 ms (Approx. 5 ms)]
2
2
Max. 8 ms (Approx. 3 ms) [10 ms (Approx. 3 ms)]
1,000 Vrms for 1min. (Detection current: 10mA.)
4,000 Vrms for 1min. (Detection current: 10mA.)
(Half-wave pulse of sine wave: 11 ms; detection time: 10 s.)
type
5
1,000
Max. 30 m (By voltage drop 6 V DC 1A)
140
(resistive load, at 20 times/min., at rated capacity)
10 to 55 Hz at double amplitude of 3 mm
Min. 5 10
8 A 250 V AC,8 A 30 V DC
2
(Half-wave pulse of sine wave: 6 ms.)
250 V AC, 125 V DC
1 Form A 1 Form B
Approx. 6 g
2,000 VA, 240 W
10m A 5 V DC
Specifications
20 times/min.
2-(1). Life curve (1 Form A)
3-(2). Operate/Release time
(1 Form A 1 Form B, 2 Form A)
Tested sample: DK1a1b-12V, 5 pcs.
7
10,000 V
200 mW
(at 300 times/min.)
1,000
8 A
100
10
1
9
8
7
6
5
4
3
2
1
0
0
.21 oz
250 V AC inductive load (cos = 0.4)
30 V DC inductive load (L/R = 7 ms)
80
Operate time
Au-flashed AgNi type
1
2
90
–40 F to +149
Release time
3
Coil applied voltage,%V
10
250 V AC resistive load
30 V DC resistive load
Contact current, A
Release time
(with diode)
4
8 A 250 V AC,8 A 30 V DC
5
110
250 V AC, 125 V DC
Approx. 6 g
2,000 VA, 240 W
6
F,
2 Form A
120
7
Max.
Min.
Max.
Min.
Max.
Min.
x
x
x
8 A
8
130
.21 oz
9 10
140

Related parts for DK1A-5V-F