G2R-1-SN-DC12 Omron, G2R-1-SN-DC12 Datasheet - Page 25

no-image

G2R-1-SN-DC12

Manufacturer Part Number
G2R-1-SN-DC12
Description
RELAY PWR SPDT 10A 12VDC QC MNT
Manufacturer
Omron
Series
G2RSr
Datasheets

Specifications of G2R-1-SN-DC12

Relay Type
General Purpose
Contact Form
SPDT (1 Form C)
Contact Rating (current)
10A
Switching Voltage
440VAC, 125VDC - Max
Coil Type
Standard
Coil Current
43.2mA
Coil Voltage
12VDC
Turn On Voltage (max)
8.4 VDC
Turn Off Voltage (min)
1.8 VDC
Mounting Type
Socket
Termination Style
Quick Connect - .187" (4.7mm)
Circuit
SPDT (1 Form C)
Contact Rating @ Voltage
10A @ 250VAC
Control On Voltage (max)
8.4 VDC
Control Off Voltage (min)
1.8 VDC
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
G2R1SNDC12

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
G2R-1-SN-DC12V
Manufacturer:
OMRON
Quantity:
1 001
■ Designing Power Circuit
Since many documents and reference books on the power circuit are
available, a detailed description is omitted here.
■ Connection of Surge
Note: This graph is plotted by measuring the surge voltage in the line
When connecting a surge suppressor, pay attention to the following
points:
1. Place the surge suppressor near the device to be protected. For
External surge
* In the circuit above, varistors B
** Resistor R protects diode bridge D from the inrush current
*** C
example, to protect a device from external surge, set the surge
suppressor at the inlet of the device’s power cable.
To suppress an internal surge, the suppressor must be placed
near the surge generating source.
Suppressor
power circuit elements, as well as elements related to the
power circuit, in case the voltage on the power line experi-
ences surges (due to lightning or the surge voltage gener-
ated in other devices connected to the power circuit).
Connect an appropriate surge suppressor across the output
terminals of the power circuit to prevent a surge voltage
from being generated. The surge suppressor must keep the
surge voltage, if generated, from exceeding the breakdown
voltage of each element in the power circuit.
that flows through the power circuit upon power application.
Although the resistance of R is determined according to the
resistance of the load coil and the ratings of the diodes, the
use of a resistor having a resistance of 0.1 to 100Ω is rec-
ommended.
large as possible to reduce the ripple percentage.
1
of low-tension overhead wiring (cable length: 200 to 500 m).
is a smoothing capacitor. Its capacitance must be as
1
to B
4
are used to protect the
Electromechanical Relays
Internal surge
2. The cable for connecting the surge suppressor must be as short
3. When using a surge suppressor between cable and ground, the
■ Countermeasures Against
In case the supply voltage fluctuates heavily, insert a regulated volt-
age circuit or constant-voltage circuit in the application circuit as
shown below.
Relays consume more power than semiconductor elements. The fol-
lowing circuit configuration is recommended to improve the charac-
teristics.
as possible in length, and thick enough in diameter so that it can
sufficiently withstand the surge current. The short length and thick
diameter are important to reduce the inductance and generated
voltage, and to protect the device from heat damage.
lower the ground resistance of the surge suppressor, the better
the protective effect of the surge suppressor. Perform grounding
at a ground resistance of 10Ω or less.
Supply Voltage Fluctuation
Technical Information
25