G5S-1-CB-DC12 Omron, G5S-1-CB-DC12 Datasheet

no-image

G5S-1-CB-DC12

Manufacturer Part Number
G5S-1-CB-DC12
Description
RELAY PCB SPDT 5A 12VDC
Manufacturer
Omron
Series
G5Sr
Datasheet

Specifications of G5S-1-CB-DC12

Relay Type
General Purpose
Contact Form
SPDT (1 Form C)
Contact Rating (current)
5A
Switching Voltage
277VAC, 30VDC - Max
Coil Type
Standard
Coil Current
33.3mA
Coil Voltage
12VDC
Turn On Voltage (max)
9 VDC
Turn Off Voltage (min)
0.6 VDC
Mounting Type
Through Hole
Termination Style
PC Pin
Circuit
SPDT (1 Form C)
Contact Rating @ Voltage
5A @ 125VAC
Control On Voltage (max)
9 VDC
Control Off Voltage (min)
0.6 VDC
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
G5S1CBDC12
Compact Single-pole Relay for
Switching Up To 5 A (Normally Open
Contact), Ideal for Fan Control of Air
Conditioners, and Heating Control of
Small Appliances
1
1
1
1
1
Ordering Information
Note: When ordering, add the rated coil voltage to the model number.
3
G5S-PP-P-P-DCP
1. Contact Pole
Classification
Single contact
PCB Relay
1: Single pole
g
Compact relay with high insulation
between coil and contacts
Up to 5A switching on the NO contacts
Ensures a withstand impulse voltage of
8,000 V between the coil and contacts
Class B coil insulation available
Conforms to UL, CSA, and IEC (TÜV)
MODEL NUMBER LEGEND
1 2 3
Example: G5S-1 DC12
4
5
2. Contact Form
nil = 1 form C
A = 1 form A
9
SPDT
SPST-NO
Rated coil voltage
3. Insulation class
nil = standard
CB = Class B
Enclosure rating
Plastic-sealed
Plastic-sealed
4. Enclosure
nil = plastic sealed
v = vented
Part number
G5S-1 (-CB for Class B)
G5S-1A (-CB for class B)
5. Rated Coil Voltage
5, 9, 12, 18, 24, 48 VDC
G5S

Related parts for G5S-1-CB-DC12

G5S-1-CB-DC12 Summary of contents

Page 1

... Contact Form 1. Contact Pole nil = 1 form C 1: Single pole form A Enclosure rating Plastic-sealed Plastic-sealed 3. Insulation class 4. Enclosure nil = standard nil = plastic sealed CB = Class vented G5S Part number G5S-1 (-CB for Class B) G5S-1A (-CB for class B) 5. Rated Coil Voltage 5, 9, 12, 18, 24, 48 VDC ...

Page 2

... Destruction Hz, 1.5-mm double amplitude for 2 hours Malfunction Hz, 1.5-mm double amplitude for 5 minutes 2 Destruction: 1,000 m/s (approx. 100G Malfunction: Energized: 100 m/s Malfunction: Energized: 100 m/s (approximately 10G) (approximately 10G) 2 Non-energized: 50 m/s (approximately 5G) (This table continues on the next page.) G5S 24 VDC 48 VDC 16.7 mA 8.3 mA 1,440 5,760 ...

Page 3

... Electrical life tests are performed Model Coil ratings G5S-1 (-CB) 5,6,9,12,18,20,24,48 G5S-1A (-CB) Note: Pollution Degree 2, Overvoltage Category II, Material Group III 5,000,000 operations (18,000 operations per hour) 200,000 operations (NO)/1 A (NC) at 277-VAC resistive load 3 A (NO)/3 A (NC) at 125-VAC resistive load 100,000 operations: 0.8 A (NO)/0.8 A (NC) at 250 VAC, cos =0.9 ...

Page 4

... Ambient temperature ( 125-VAC resistive load (NO) 1 0.5 0 277 1,000 0 3 LIFE EXPECTANCY 10,000 1,000 100 250 VAC (cos =0. 250-VAC inductive load (cos =0.8) 250-VAC inductive load (cos =0.4) 10 100 277 1,000 Switching voltage (V) 125 VAC (NO only) 277 VAC Switching current (A) G5S ...

Page 5

... G5S Dimensions Unit: mm (inch) 3 G5S SPDT (See (See Note.) Note.) Note: Values in parentheses are average values. 3 SPST-NO (See (See Note.) Note.) Note: Values in parentheses are average values. Precautions For general precautions on PCB Relays, refer to the precautions provided in General Information of the Relay Product Data Book. ...

Page 6

... NOTE: DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches divide by 25.4. 9 OMRON ELECTRONICS, INC. One East Commerce Drive Schaumburg, IL 60173 1-800-55-OMRON Cat. No. GC RLY7 01/00 Specifications subject to change without notice. OMRON CANADA, INC. 885 Milner Avenue Scarborough, Ontario M1B 5V8 416-286-6465 Printed in U.S.A. ...

Related keywords