G5Q-14 DC18 Omron, G5Q-14 DC18 Datasheet - Page 2

no-image

G5Q-14 DC18

Manufacturer Part Number
G5Q-14 DC18
Description
RELAY PWR SPDT 18VDC PCB
Manufacturer
Omron
Series
G5Qr
Datasheet

Specifications of G5Q-14 DC18

Relay Type
General Purpose
Contact Form
SPDT (1 Form C)
Contact Rating (current)
10A
Switching Voltage
277VAC, 30VDC - Max
Coil Type
Standard
Coil Current
22.2mA
Coil Voltage
18VDC
Turn On Voltage (max)
13.5 VDC
Turn Off Voltage (min)
0.9 VDC
Mounting Type
Through Hole
Termination Style
PC Pin
Circuit
SPDT (1 Form C)
Contact Rating @ Voltage
10A @ 125VAC
Control On Voltage (max)
13.5 VDC
Control Off Voltage (min)
0.9 VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
G5Q-14DC18
G5Q14DC18
■ Contact Ratings
■ Characteristics
Note: 1. The data shown above are initial values.
146
Item
Rated load (resistive)
Contact material
Rated carry current
Max. switching voltage
Max. switching current
Max. switching capacity
Min. permissible load
Contact resistance (See note 2.)
Operate time
Release time
Insulation resistance (See note 3.)
Dielectric strength
Impulse withstand voltage
Vibration resistance
Shock resistance
Life expectancy (See Note 4)
Ambient temperature
Ambient humidity
2. The contact resistance is measured with 1 A applied at 5 VDC using a fall-of-potential method.
3. The insulation resistance is measured between coil and contacts and between contacts of the same polarity at 500 VDC.
4. The electrical life data items shown are possible at 23°C
PCB Relay
G5Q
Mechanical
Electrical
Operating &
storage
Operating &
storage
SPDT
10 A at 125 VAC (NO)
3 A at 250 VAC (NO)
5 A at 30 VDC (NO)
3 A at 125 VAC (NC)
3 A at 30 VDC (NC)
Ag alloy
10 A (NO)/3 A (NC)
277 VAC, 30 VDC
AC: 10 A (NO)/3 A (NC)
DC: 5 A (NO)/3 A (NC)
1250 VA, 150 W (NO)
375 VA, 90 W (NC)
10 mA at 5 VDC (
100 mΩ max.
10 ms max.
5 ms max.
1,000 mΩ min.
4,000 VAC, 50/60 Hz for 1 min between coil and contacts
1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity
8 kV (1.2 × 50 μs) between coil an contacts
Destruction: 10 to 55 to 10 Hz, 1.5-mm double amplitude
Malfunction: 10 to 55 to 10 Hz, 1.5-mm double amplitude
Destruction: 1000 m/s
Malfunction: 100 m/s
10,000,000 operations (18,000 operations per hour)
200,000 operations: 3 A (NO)/3 A (NC) at 125 VAC, resistive load
100,000 operations: 3 A (NO)/3 A (NC) at 250 VAC,
50,000 operations: 10 A at 125 VAC (900 operations per hour)
−40
5% to 85%
°
C to 105°C (-40°F to 221°F) with no icing or condensation
P level: λ
2
5 A (NO)/3 A (NC) at 30 VDC, resistive load
2
(approx. 10G)
(approx. 100G)
60
= 0.1 × 10
−6
/operation)
SPST-NO
10 A at 125 VAC
3 A at 250 VAC
5 A at 30 VDC

Related parts for G5Q-14 DC18