JA1A-TMP-AC220V-P Panasonic Electric Works, JA1A-TMP-AC220V-P Datasheet - Page 4

no-image

JA1A-TMP-AC220V-P

Manufacturer Part Number
JA1A-TMP-AC220V-P
Description
RELAY POWER 25A 220VAC SLD/PCB
Manufacturer
Panasonic Electric Works
Series
JAr
Datasheet

Specifications of JA1A-TMP-AC220V-P

Relay Type
General Purpose
Contact Form
SPST-NO (1 Form A)
Contact Rating (current)
25A
Switching Voltage
250VAC
Coil Type
Standard
Coil Current
6.3mA
Coil Voltage
220VAC
Turn On Voltage (max)
176 VAC
Turn Off Voltage (min)
66 VAC
Mounting Type
Through Hole
Termination Style
PC Pin, .250" Quick Connect
Circuit
SPST-NO (1 Form A)
Contact Rating @ Voltage
25A @ 250VAC
Control On Voltage (max)
176 VAC
Control Off Voltage (min)
66 VAC
Lead Free Status / RoHS Status
Lead free / RoHS non-compliant
5.-(1) Release time (1a-AC type)
6.-(1) Electrical life (15 A 250 V AC resistive)
1. Tested sample: JA1c-TMP-AC115V
2. Load: 15 A 250 V AC resistive load
3. Cycle rate: 20 cpm.
4. Circuit:
6.-(2) Electrical life (15 A 250 V AC Motor
simulated load)
1. Tested sample: JA1a-TM-DC12V
2. Load: 250 V AC inductive load (cos = 0.7)
3. Cycle rate: 20 cpm.
4. Circuit:
For Cautions for Use
6/1/1999
250 V AC
250 V AC
20
18
16
14
12
10
15 A steady and 55 A (0.3s*) inrush current
8
6
4
2
0
80
90
Coil applied voltage, %V
N.C.
N.C.
100
N.O.
110
R
R
L
L
15 A
15 A
120
Max.
Min.
R
L
5.-(2) Release time (1a-DC type)
TEST RESULT:
1. Pick-up and drop-out voltage
TEST RESULT:
1. Pick-up and drop-out voltage
* This shows percent rate against nominal coil voltage.
10
80
70
60
50
40
30
20
10
9
8
7
6
5
4
3
2
1
0
0
5
4
3
2
1
0
80
10
Drop-out voltage
Pick-up voltage
Pick-up voltage
Drop-out voltage
No. of operations, 10
No. of operations, 10
Coil applied voltage, %V
90
5
100
30
110
4
4
120
All Rights Reserved, © Copyright Matsushita Electric Works, Ltd.
Max.
Min.
10
50
Max.
Mean value
Min.
Max.
Mean value
Min.
Max.
Max.
Min.
Min.
2. Contact resistance
3. No abnormality was observed in either insulation
resistance or breakdown voltage.
2. Contact resistance
3. No abnormality was observed in either insulation
resistance or breakdown voltage.
30
10
30
10
10
0
0
5
0
N.O. contact
10
10
N.C. contact
N.C. contact
No. of operations, 10
No. of operations, 10
No. of operations, 10
5
Go To Online Catalog
30
30
4
4
4
50
50
10
Max.
Mean
value
Min.
Mean
value
Max.
Mean value
Min.

Related parts for JA1A-TMP-AC220V-P