NF2EB-12V Panasonic Electric Works, NF2EB-12V Datasheet - Page 3

RELAY 2A 12VDC AMB FLATPACK PCB

NF2EB-12V

Manufacturer Part Number
NF2EB-12V
Description
RELAY 2A 12VDC AMB FLATPACK PCB
Manufacturer
Panasonic Electric Works
Series
NFr
Datasheets

Specifications of NF2EB-12V

Relay Type
General Purpose
Circuit
DPDT (2 Form C)
Contact Rating @ Voltage
2A @ 30VDC
Coil Type
Standard
Coil Current
36.67mA
Coil Voltage
12VDC
Control On Voltage (max)
9.6 VDC
Control Off Voltage (min)
1.2 VDC
Mounting Type
Through Hole
Termination Style
PC Pin
Brand/series
NF Series
Contact Form
DPDT
Current, Rating
2 A
Function
General Purpose
Number Of Pins
9
Power, Rating
100 VA
Standards
UL, CSA
Termination
Solder
Voltage, Control
12 V
Voltage, Rating
220 VAC/VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
255-2239
NF2EB-12V

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
NF2EB-12V
Manufacturer:
ARM
Quantity:
714
Part Number:
NF2EB-12V
Manufacturer:
ON
Quantity:
5 510
ds_61014_en_nf: 040804J
NF
REFERENCE DATA
1. Life curve
4. Contact reliability
Test conditions:
1. Contact current/voltage: 10
2. Cycle rate 20 cps.
3. Miscontact detection level: 1 mW (= 100
4. Detection method: Observation of all changeover
contacts
Test result:
m = 1.5
µ
95% confidence level = 3.1
17 contacts out of 20 achieved 10 million no miscon-
tact operations.
NOTES
1. Prevention of vibration and shock
To reduce the likelihood of vibration and
shock, we recommend that you install so
that the contact action is not in the direc-
tion of gravity.
For Cautions for Use, see Relay Technical Information in catalog.
= 21.2
95.0
80.0
60.0
40.0
25.0
15.0
0.15
F(t)(%)
4.0
1.5
0.4
1,000
99.9
99.0
90.0
70.0
50.0
30.0
20.0
10.0
5.0
3.0
2.0
1.0
0.5
0.3
0.2
100
0.1
10
×
0.1
10
Common terminal
6
Coil terminal
NC terminal
NO terminal
0.5
0.5 1.0
No. of operations, ×10
1
30 V DC Resistive
Load current, A
×
10
µ
1.5
5.0 10.0
A 100 mV 1 kHz
6
Bottom
Top
2
6
2.5
50 100
)
2. Coil temperature rise (resistance method)
5. High temperature test
Test conditions:
Ambient temperature: 80
Test method:
1. All contacts were switched for 100 operations on 2
A 30 V DC resistive load.
2. Samples then were exposed to 80
for 5,000 hours, continuous
3. Contact resistance was measured with Hewlett-
Packard testing equipment.
70
60
50
40
30
20
10
0
60
40
20
100 200 300 400 500 1,000
0.2 0.4 0.6 0.8 1.0 1.2 1.4
N.C. contacts
N.O. contacts
Operating power, W
Exposure, hrs.
°
C
±
2
°
C
°
C temperature
3,000
5,000
Max.
Min.
Max.
Min.
3. H
Test result:
Amber relays showed a stable spread of contact resis-
tance within the initially specified 50 m
hours exposure.
2
S gas test
500mΩ
100mΩ
50mΩ
100Ω
50Ω
10Ω
5Ω
1Ω
20 50 100 200 1,000
500
Exposure time, hrs
Sealed NFEB relay
2,000
Gas density:
Temperature: 40°C
Humidity: 90%
2 to 5 ppm
after 5,000
3