G5V-1-DC6 Omron, G5V-1-DC6 Datasheet

RELAY MINI PCB SPDT 1A 6VDC

G5V-1-DC6

Manufacturer Part Number
G5V-1-DC6
Description
RELAY MINI PCB SPDT 1A 6VDC
Manufacturer
Omron
Series
G5V-1r
Datasheets

Specifications of G5V-1-DC6

Coil Type
Standard
Coil Current
25mA
Relay Type
General Purpose
Circuit
SPDT (1 Form C)
Contact Rating @ Voltage
1A @ 24VDC
Coil Voltage
6VDC
Control On Voltage (max)
4.8 VDC
Control Off Voltage (min)
0.6 VDC
Mounting Type
Through Hole
Termination Style
PC Pin
Contact Form
1 Form C
Power Consumption
150 mW
Maximum Switching Current
2 A
Contact Configuration
SPDT
Contact Current Max
1A
Contact Voltage Ac Nom
125V
Contact Voltage Dc Nom
24V
Coil Voltage Vdc Nom
6V
Current, Rating
1 A
Function
Sensitive
Number Of Pins
6
Power, Rating
62.5⁄30 VA⁄W
Standards
UL, CSA, RoHS
Termination
Through Hole
Voltage, Control
6 VDC
Voltage, Rating
125 VAC
High Sensitivity
150 mW Nominal Power Consumption
Small Size
10 mm (H) × 7.5 mm (W) × 12.5 mm (L)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
G5V-1-DC6
G5V1DC6
Z2538
• High sensitivity: 150 mW nominal power consumption with
• Small size at 10 H x 7.5 W x 12.5 L mm (0.394 H x 0.295 W
• Conforms to FCC part 68 voltage surge.
• Fully-sealed construction.
• Ideal for use in telecommunications, security, and comput-
• RoHS Compliant.
Ordering Information
To Order: Select the part number and add the desired coil voltage rating (e.g., G5V-1-DC12).
Note: Reflow solder process version is also available in PCB through-hole configuration. Please consult your local Omron sales representative for
Specifications
■ Contact Data
■ Coil Data (G5V-1, G5V-1-2)
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23° C (73° F) with a tolerance of ±10%.
PCB through-hole
Rated load
Contact material
Carry current
Max. operating voltage
Max. operating current
Max. switching capacity
Min. permissible load
3
5
6
9
12
24
96 mW pickup power.
x 0.492 L in).
er/peripheral equipment.
Low Signal Relay
G5V-1
voltage
Rated
(VDC)
more information.
2. The operating characteristics are measured at a coil temperature of 23° C (73° F).
Terminal
Rated current
50
30
25
16.70
12.50
6.30
Load
(mA)
Standard
Special pickup
60
166.70
240
540
960
3,840
resistance
Coil
(Ω)
Type
0.50 A at 125 VAC, 1A 24 VDC
Ag (Au clad)
2 A
125 VAC, 60 VDC
1 A
62.50 VA, 30W
1 mA, 5 VDC
0.11
0.29
0.41
0.93
1.63
6.61
Armature OFF
Coil inductance
(Ref. value) (H)
Resistive load (p.f. = 1)
SPDT
Contact form
0.05
0.15
0.20
0.45
0.85
3.48
Armature ON
Single crossbar
80%
70%
(special pickup)
Contact type
Pick-up
voltage
Low Signal Relay
% of rated voltage
10% min.
Dropout
Inductive load (p.f. = 0.4, L/R = 7ms)
voltage
Fully sealed
Construction
200%
at 55° C
(131° F)
160%
at 70° C
(158° F)
Maximum
voltage
G5V-1
G5V-1
G5V-1-2
Approx. 150
consumption
Model
Power
(mW)
1

Related parts for G5V-1-DC6

G5V-1-DC6 Summary of contents

Page 1

... Conforms to FCC part 68 voltage surge. • Fully-sealed construction. • Ideal for use in telecommunications, security, and comput- er/peripheral equipment. • RoHS Compliant. Ordering Information To Order: Select the part number and add the desired coil voltage rating (e.g., G5V-1-DC12). Terminal Type PCB through-hole Standard Special pickup Note: Reflow solder process version is also available in PCB through-hole configuration ...

Page 2

... Service life Mechanical Electrical Weight Note: Data shown are of initial value. ■ Characteristic Data Maximum switching capacity G5V-1 2 Low Signal Relay 100 mΩ max max. (mean value: approx. 2.50 ms max. (mean value: approx. 0.90 ms max. (mean value: approx. 0.17 ms) 36,000 operations/hour 1,800 operations/hour 1,000 MΩ ...

Page 3

... Dimensions Unit: mm (inch) ■ Relays G5V-1, G5V-1-2 ■ Approvals UL (File No. E41515)/CSA (File No. LR24825) Type G5V-1 SPDT G5V-1-2 Note the interest of product improvement, specifications are subject to change. 2. Complies with UL 1950 basic Insulation at 125 V (pollution degree 1 for internal spacings, pollution degree 2 for external spacings). ...

Related keywords