G6E-134P-ST-US-DC3 Omron, G6E-134P-ST-US-DC3 Datasheet - Page 6

RELAY SPDT PCB 2A 3VDC

G6E-134P-ST-US-DC3

Manufacturer Part Number
G6E-134P-ST-US-DC3
Description
RELAY SPDT PCB 2A 3VDC
Manufacturer
Omron
Series
G6Er

Specifications of G6E-134P-ST-US-DC3

Coil Type
Standard
Coil Current
66.7mA
Relay Type
General Purpose
Circuit
SPDT (1 Form C)
Contact Rating @ Voltage
2A @ 30VDC
Coil Voltage
3VDC
Control On Voltage (max)
2.1 VDC
Control Off Voltage (min)
0.3 VDC
Mounting Type
Through Hole
Termination Style
PC Pin
Contact Configuration
SPDT
Contact Current Max
3A
Contact Voltage Ac Nom
125V
Contact Voltage Dc Nom
30V
Coil Voltage Vdc Nom
3V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
G6E-134P-ST-USDC3
G6E-134P-ST-USDC3
G6E134PSTUSDC3
Z2599

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
G6E-134P-ST-US-DC3
Manufacturer:
OMRON/欧姆龙
Quantity:
20 000
Precautions
■ Precautions for Correct Use
Long-term Continuously ON Contacts
Using the Relay in a circuit where the Relay will be ON continuously
for long periods (without switching) can lead to unstable contacts
because the heat generated by the coil itself will affect the insulation,
causing a film to develop on the contact surfaces. We recommend
using a latching relay (magnetic-holding relay) in this kind of circuit. If
a single-side stable model must be used in this kind of circuit, we rec-
ommend using a fail-safe circuit design that provides protection
against contact failure or coil burnout.
Installation
Do not reverse the polarity of the coil (+, -).
Provide sufficient space between Relays when mounting two or more
on the same PCB, as shown in the following diagram.
■ Hints on Correct Use
Single-winding type (G6EU)
Example of low-power consumption driver circuit
1. This is an example of a driver circuit that allows Model G6E to
2. The relay is set by an abrupt current charged to capacity C. This
3. The relay is reset by the discharge current of C flowing in the relay
Note: 1. Give adequate consideration to the circuit constant when
94
function as a normal relay with a normal switching pulse input.
current flows in the relay via diode D
via transistor TR and C.
2. OMRON owns the patent on this circuit. Consult OMRON
actually using this circuit, confirming the set and reset status
of the relay.
when using this circuit.
Low Signal Relay
Close
mounting
Distance between terminals:
2.54 × 2 (pitch) max.
G6E
1
and C and out via diode D
2
.
Wiring
Refer to the following diagram when wiring to switch a DC load. The
difference in polarity applied to the contacts will affect the endurance
of the Relay due to the amount of contact movement. To extend the
endurance characteristics beyond the performance ratings, wire the
common (pin 7) terminal to the positive (+) side.
Ultrasonic Cleaning
Do not use ultrasonic cleaning on standard relay models. Doing so
may result in resonance, coil burnout, and contact adhesion within
the Relay.
Relay Handling
When washing the product after soldering the Relay to a PCB, use a
water-based solvent or alcohol-based solvent, and keep the solvent
temperature to less than 40°C. Do not put the Relay in a cold clean-
ing bath immediately after soldering.
+
Wiring Diagram
Load
12
7
10
Load