G6Z-1FE-A DC12 Omron, G6Z-1FE-A DC12 Datasheet - Page 15

RELAY HI FREQ 50 OHM SMD

G6Z-1FE-A DC12

Manufacturer Part Number
G6Z-1FE-A DC12
Description
RELAY HI FREQ 50 OHM SMD
Manufacturer
Omron
Series
G6Zr
Datasheets

Specifications of G6Z-1FE-A DC12

Relay Type
RF
Circuit
SPDT (1 Form C)
Contact Rating @ Voltage
0.01A @ 30VAC/DC
Coil Type
Standard
Coil Current
16.7mA
Coil Voltage
12VDC
Control On Voltage (max)
9 VDC
Control Off Voltage (min)
1.2 VDC
Mounting Type
Surface Mount
Termination Style
Gull Wing
Coil Frequency Max
2.6GHz
Coil Voltage Vdc Nom
12V
Contact Current Max
500mA
Contact Voltage Ac Nom
30V
Contact Voltage Dc Nom
30V
Coil Resistance
720ohm
Contact Configuration
SPDT
Contact Form
SPDT (1 Form C)
Contact Rating (current)
0.01A
Switching Voltage
30VAC, 30VDC - Max
Turn On Voltage (max)
9 VDC
Turn Off Voltage (min)
1.2 VDC
Features
Sealed - Fully
Contact Material
Copper (Cu), Gold (Au)
Operate Time
10ms
Release Time
10ms
Coil Power
200 mW
Operating Temperature
-40°C ~ 70°C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
G6Z-1FE-ADC12
G6Z1FEADC12
Claw Securing Force During Automatic Mounting
During automatic insertion of Relays, be sure to set the securing
force of each claw to the following so that the Relay’s characteristics
will be maintained.
Latching Relay Mounting
Make sure that the vibration or shock that is generated from other
devices, such as Relays, on the same panel or substrate and
imposed on the Latching Relay does not exceed the rated value, oth-
erwise the set/reset status of the Latching Relay may be changed.
The Latching Relay is reset before shipping. If excessive vibration or
shock is imposed, however, the Latching Relay may be set acciden-
tally. Be sure to apply a reset signal before use.
Coating
Do not use silicone coating to coat the Relay when it is mounted to
the PCB. Do not wash the PCB after the Relay is mounted using
detergent containing silicone. Otherwise, the detergent may remain
on the surface of the Relay.
Secure the claws to the shaded area.
Do not attach them to the center area
or to only part of the Relay.
B
Direction A: 4.90 N max.
Direction B: 4.90 N max.
Direction C: 4.90 N max.
High-frequency Relay
G6Z
355

Related parts for G6Z-1FE-A DC12