DS2E-M-DC12V-TB Panasonic Electric Works, DS2E-M-DC12V-TB Datasheet - Page 3

RELAY MINI 12VDC 400MW PCB T&B

DS2E-M-DC12V-TB

Manufacturer Part Number
DS2E-M-DC12V-TB
Description
RELAY MINI 12VDC 400MW PCB T&B
Manufacturer
Panasonic Electric Works
Series
DSr
Datasheet

Specifications of DS2E-M-DC12V-TB

Relay Type
General Purpose
Circuit
DPDT (2 Form C)
Contact Rating @ Voltage
2A @ 30VDC
Coil Type
Standard
Coil Current
33.3mA
Coil Voltage
12VDC
Control On Voltage (max)
8.4 VDC
Control Off Voltage (min)
1.2 VDC
Mounting Type
Through Hole
Termination Style
PC Pin
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
2) 2 coil latching type
2. Specifications
Notes: *1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
Contact
Rating
Electrical
characteristics
Mechanical
characteristics
Expected life
Conditions
Unit weight
sensitivity
Standard
(M) type
(S) type
Characteristics
Type
High
*2 Half-wave pulse of sine wave: 11ms; detection time: 10µs
*3 Refer to 6. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT.
actual load.
(SX relays are available for low level load switching [10V DC, 10mA max. level])
Nominal coil
1.5V DC
1.5V DC
12V DC
24V DC
48V DC
12V DC
24V DC
48V DC
voltage
3V DC
5V DC
6V DC
9V DC
3V DC
5V DC
6V DC
9V DC
Arrangement
Initial contact resistance, max.
Contact material
Nominal switching capacity
Max. switching power
Max. switching voltage
Max. carrying current
Min. switching capacity (Reference value)*
Nominal operating power
Insulation resistance (Initial)
Breakdown voltage
(Initial)
Temperature rise
Operate time [Set time] (at 20°C 68°F)
Release time [Reset time] (at 20°C 68°F)
Shock resistance
Vibration resistance
Mechanical
Electrical
Conditions for operation, transport and storage*
Max. operating speed (at rated load)
70%V or less of
nominal voltage
80%V or less of
nominal voltage
70%V or less of
nominal voltage
(at 20°C 68°F)
Set voltage
1 Form C:
2 Form C:
(Initial)
(Initial)
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
Between open contacts
Between contact and coil
Functional*
Destructive
Functional
Destructive
Item
70%V or less of
nominal voltage
80%V or less of
nominal voltage
70%V or less of
nominal voltage
(at 20°C 68°F)
Reset voltage
2
1 Form C:
2 Form C:
(Initial)
(Initial)
1
3
3.75mA
Set coil
240mA
120mA
120mA
7.5mA
7.5mA
Nominal operating
Max. 10 ms [10 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.)
72mA
60mA
40mA
30mA
15mA
60mA
36mA
30mA
20mA
15mA
Max. 5 ms [10 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.)
(By resistive method, nominal coil voltage applied to the coil, contact carrying current: 2A.)
current [±10%]
(at 20°C 68°F)
(1,000 Vrms for 1min: 1 Form C high sensitivity type) (Detection current: 10mA.)
(500 Vrms for 1min: 1 Form C high sensitivity type) (Detection current: 10mA.)
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Reset coil
3.75mA
Measurement at same location as “Initial breakdown voltage” section.
240mA
120mA
120mA
7.5mA
7.5mA
72mA
60mA
40mA
30mA
15mA
60mA
36mA
30mA
20mA
15mA
10 to 55 Hz at double amplitude of 3.3 mm (Detection time: 10µs.)
Approx. 3 g
Min. 490 m/s
1 Form C
Ambient temperature: –40°C to +70°C
Single side stable (M type: 400 mW, S type: 200 mW);
Min. 980 m/s
Min. 10
12,800Ω
Set coil
1,600Ω
6,400Ω
3,200Ω
6.25Ω
69.4Ω
12.5Ω
latching (M type: 360 mW, S type: 180 mW)
100Ω
225Ω
400Ω
139Ω
200Ω
450Ω
800Ω
25Ω
50Ω
Max. 50 mΩ (By voltage drop 6 V DC 1A)
.11 oz
Coil resistance
10 to 55 Hz at double amplitude of 5 mm
(at 20°C 68°F)
8
2
(10
Min. 5×10
[±10%]
60 W, 125 VA (resistive load)
2 A 30 V DC (resistive load)
7
Min. 100MΩ (at 500V DC)
2
: 1 Form C latching type) (at 600 cpm)
Reset coil
(Half-wave pulse of sine wave: 6 ms.)
12,800Ω
1,600Ω
6,400Ω
3,200Ω
1,000 Vrms for 1min.
1,500 Vrms for 1min.
220 V DC, 250 V AC
6.25Ω
69.4Ω
12.5Ω
100Ω
225Ω
400Ω
139Ω
200Ω
450Ω
800Ω
25Ω
50Ω
10µA 10m V DC
(without diode)
Specifications
5
Ag+Au clad
rated load (at 60 cpm)
Max. 65°C
60 cpm
3 A
360mW
Set coil
180mW
Nominal operating
power
–40°F to +158°F
Reset coil
360mW
180mW
Approx. 4g
Min. 490 m/s
2 Form C
Max. applied voltage
.14oz
(at 50°C 122°F)
nominal voltage
nominal voltage
nominal voltage
nominal voltage
2
1 Form C:
2 Form C:
1 Form C:
2 Form C:
120%V of
150%V of
160%V of
200%V of
DS

Related parts for DS2E-M-DC12V-TB