HC4E-HP-AC240V Panasonic Electric Works, HC4E-HP-AC240V Datasheet - Page 8

no-image

HC4E-HP-AC240V

Manufacturer Part Number
HC4E-HP-AC240V
Description
RELAY PWR 2A 4PDT 240VAC PCB
Manufacturer
Panasonic Electric Works
Series
HCEr
Datasheet

Specifications of HC4E-HP-AC240V

Relay Type
General Purpose
Circuit
4PDT (4 Form C)
Contact Rating @ Voltage
2A @ 125VAC
Coil Type
Standard
Coil Current
5mA
Coil Voltage
240VAC
Control On Voltage (max)
192 VAC
Control Off Voltage (min)
72 VAC
Mounting Type
Through Hole
Termination Style
PC Pin
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
HC
3. TM type
Chassis (Panel) cutout
Schematic
Same schematic as plug-in type HC relay
Be aware that there is no LED indicator with CR
circuit and built-in diode types.
For Cautions for Use, see Relay Technical Information.
2-3.6 dia.
2-.142 dia.
1.480
37.6
Tolerance: 0.1
.004
4 Form C type External dimensions
.142
3.6
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
13
1
5
9
13.35
.526
4.45
.175
20.6
.811
10
2
6
Chassis (Panel) cutout in tandem mounting
Notes: 1. In mounting, use M3 screws and M3 washers.
11
3
7
4
8
12
14
4.31
.170
.039
2.54
.100
4.06
.160
6.35
.250
6.35
.250
1
34.2
1.346
6.4
.252
2. When mounting TM types, use washers to prevent damage or distortion to the polycarbonate cover.
3. When tightening fixing screws, the optimum torque range should be 0.294 to 0.49 N·m, (3 to 5 kgf·cm).
27
1.063
Moreover, use washers to prevent loosening.
.020
0.5
37.6
1.480
1.480
37.6
General tolerance: 0.3
1.693
43
.827
.079
21
2
.906
23
.827
21
2
.079
.012
The diagrams show the external dimensions of
the 4 Form C and 4-pole bifurcated (twin) types.
For 1 Form C, 2 Form C, and 3 Form C, see
diagrams at plug-in types (only the terminals are
different).

Related parts for HC4E-HP-AC240V