RELAY OPTOMOS SP-NO 100MA 4-SOP

CPC1016NTR

Manufacturer Part NumberCPC1016NTR
DescriptionRELAY OPTOMOS SP-NO 100MA 4-SOP
ManufacturerClare
SeriesCPC, OptoMOS®
CPC1016NTR datasheet
 


Specifications of CPC1016NTR

CircuitSPST-NO (1 Form A)Output TypeAC, DC
On-state Resistance16 OhmLoad Current100mA
Voltage - Input1.2VDCVoltage - Load0 ~ 100 V
Mounting TypeSurface MountTermination StyleGull Wing
Package / Case4-SOPLoad Voltage Rating100 V
Load Current Rating100 mARelay TypeSingle Pole
Lead Free Status / RoHS StatusLead free / RoHS CompliantOther namesCLA232TR
CPC1016NTR
1
Page 1
2
Page 2
3
Page 3
4
Page 4
5
Page 5
6
Page 6
Page 1/6

Download datasheet (130Kb)Embed
Next
Parameter
Rating
Blocking Voltage
100
Load Current
100
Max On-resistance
16
Features
1500V
Input/Output Isolation
rms
100% Solid State
Low Drive Power Requirements (TTL/CMOS
Compatible)
Arc-Free With No Snubbing Circuits
No EMI/RFI Generation
Machine Insertable, Wave Solderable
Tape & Reel Version Available
Applications
Instrumentation
Multiplexers
Data Acquisition
Electronic Switching
I/O Subsystems
Meters (Watt-Hour, Water, Gas)
Medical Equipment—Patient/Equipment
Isolation
Security Systems
Aerospace
Industrial Controls
Reed Relay Replacement
e
Pb
3
RoHS
2002/95/EC
DS-CPC1016N-R07
Single-Pole, Normally Open
4-Lead SOP OptoMOS
Description
Units
V
CPC1016N is a miniature, low-voltage, low
P
mA
on-resistance, normally open (1-Form-A) solid state
Ω
relay in a 4-lead SOP package. The relay uses
optically coupled MOSFET technology to provide
1500V
of input/output isolation. The efficient
rms
MOSFET switches and photovoltaic die use Clare’s
patented OptoMOS architecture while the optically
coupled output is controlled by a highly efficient
GaAIAs infrared LED.
The CPC1016N uses Clare’s state of the art
double-molded vertical construction packaging to
produce a very compact solid state relay that is
ideal for replacing larger, less-reliable reed and
electromechanical relays.
Approvals
UL Recognized Component: File E76270
CSA Certified Component: Certificate 1175739
EN/IEC 60950-1 Certified Component:
TUV Certificate B 09 07 49410 004
Ordering Information
Part #
CPC1016N
CPC1016NTR
Pin Configuration
+ Control
-
Control
of Normally Open Devices
Form-A
I
F
I
LOAD
www.clare.com
CPC1016N
®
Relay
Description
4-Lead SOP (100/tube)
4-Lead SOP (2000/reel)
1
4
Load
2
3
Load
Switching Characteristics
90%
10%
t
t
on
off
1

CPC1016NTR Summary of contents

  • Page 1

    ... Approvals • UL Recognized Component: File E76270 • CSA Certified Component: Certificate 1175739 • EN/IEC 60950-1 Certified Component: TUV Certificate 49410 004 Ordering Information Part # CPC1016N CPC1016NTR Pin Configuration + Control - Control of Normally Open Devices Form LOAD www.clare.com CPC1016N ® ...

  • Page 2

    ... rms ºC ºC Conditions Symbol - I L t=10ms I LPK I =100mA =100V LEAK =5mA, V =10V off V =50V, f=1MHz C L OUT I =100mA =5mA = I/O www.clare.com CPC1016N Min Typ Max Units - - 100 350 - - 0 0 0.3 0 0.9 1.2 1 Ω μ μA pF R07 ...

  • Page 3

    ... I =5mA F 1.5 1.0 0.5 I =10mA F 0 120 -40 - Temperature (ºC) www.clare.com CPC1016N Typical On-Resistance Distribution (N=50, I =100mA, T =25º 0.27 6.8 6.9 7.0 7.1 7.2 7.3 On-Resistance (Ω) Typical Blocking Voltage Distribution (N=50, T =25ºC) ...

  • Page 4

    ... Temperature (ºC) (V =100V ) L P 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 10μs 100μ 100 Temperature (ºC) www.clare.com CPC1016N Typical On-Resistance vs. Temperature (I =Max Rated @ Temperature =5mA Steady State 8 Instantaneous I =5mA 100 -40 - Temperature (ºC) Typical Blocking Voltage vs ...

  • Page 5

    ... Clare recommends the use of no-clean flux formulations. However, board washing to remove flux residue is acceptable. Since Clare employs the use of silicone coating as an optical waveguide in many of its optically isolated products, the use of a short drying bake could be necessary if a wash is used after solder reflow processes. ...

  • Page 6

    ... The products described in this document are not designed, intended, authorized or warranted for use as components in systems intended for surgical implant into the body other applications intended to support or sustain life, or where malfunction of Clare’s product may result in direct physical harm, injury, or death to a person or severe property or environmental damage ...