G3NA-225B DC5-24 Omron, G3NA-225B DC5-24 Datasheet

RELAY SSR 120VAC@25A ZERO DC IN

G3NA-225B DC5-24

Manufacturer Part Number
G3NA-225B DC5-24
Description
RELAY SSR 120VAC@25A ZERO DC IN
Manufacturer
Omron
Series
G3NAr

Specifications of G3NA-225B DC5-24

Load Current
25A
Circuit
SPST-NO (1 Form A)
Output Type
AC, Zero Cross
Voltage - Input
5 ~ 24VDC
Voltage - Load
19 ~ 264 V
Mounting Type
Chassis Mount
Termination Style
Screw Terminal
Package / Case
Hockey Puck
Control Voltage Range
5VDC To 24VDC
Operating Voltage Range
19VAC To 264VAC
Isolation Voltage
2500VAC
Control Voltage Type
DC
Relay Terminals
Screw
Load Voltage Max
240VAC
Load Voltage Min
24VAC
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
On-state Resistance
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
G3NA-225B-DC5-24
G3NA225BDC524
Z921
A Wide Range of Models with 5- to 40-A
Output Currents and Up to
480-VAC/200-VDC Output Voltages
Ordering Information
*Loss time increases under 75 VAC. (Refer to page 163.)
Note: When ordering a TÜV-approved model, add “-UTU” to the model number as shown below:
156
Phototriac
Photocoupler
Photocoupler
Phototriac
Photocoupler
Phototriac
Photocoupler
Phototriac
Photocoupler
All models feature the same compact dimensions
to provide a uniform mounting pitch.
Built-in varistor effectively absorb external surges.
Operation indicator (red LED) enables monitoring
operation.
Protective cover for greater safety.
Standard models approved by UL/CSA and -UTU
models by VDE (TÜV).
Isolation
Solid-state Relay
Example: G3NA-210B-UTU
p
p
p
Yes
---
Yes
Zero cross
function
Yes
Indicator
5 A at 24 to 240 VAC*
(19 t 264 VAC)
(19 to 264 VAC)
10 A at 24 to 240 VAC*
(19 t 264 VAC)
(19 to 264 VAC)
10 A at 200 to 480 VAC*
(180 t 528 VAC)
(180 to 528 VAC)
10 A at 5 to 200 VDC
(4 t 220 VDC)
(4 to 220 VDC)
20 A at 24 to 240 VAC*
(19 t 264 VAC)
(19 to 264 VAC)
20 A at 200 to 480 VAC*
(180 t 528 VAC)
(180 to 528 VAC)
40 A at 24 to 240 VAC*
(19 t 264 VAC)
(19 to 264 VAC)
40 A at 200 to 480 VAC*
(180 t 528 VAC)
(180 to 528 VAC)
50 A at 200 to 480 VAC*
(180 to 528 VAC)
(Applicable output load)
Rated output load
5 to 24 VDC
100 to 120 VAC
200 to 240 VAC
5 to 24 VDC
100 to 120 VAC
200 to 240 VAC
5 to 24 VDC
100 to 240 VAC
5 to 24 VDC
100 to 240 VAC
5 to 24 VDC
100 to 120 VAC
200 to 240 VAC
5 to 24 VDC
100 to 240 VAC
5 to 24 VDC
100 to 120 VAC
200 to 240 VAC
5 to 24 VDC
100 to 240 VAC
5 to 24 VDC
Rated input voltage
G3NA
G3NA-205B
G3NA-210B
G3NA-410B
G3NA-D210B
G3NA-220B
G3NA-420B
G3NA-240B
G3NA-440B
G3NA-450B
RCE
Model

Related parts for G3NA-225B DC5-24

G3NA-225B DC5-24 Summary of contents

Page 1

... Photocoupler p Phototriac Photocoupler p *Loss time increases under 75 VAC. (Refer to page 163.) Note: When ordering a TÜV-approved model, add “-UTU” to the model number as shown below: Example: G3NA-210B-UTU 156 Indicator Rated output load (Applicable output load 240 VAC* Yes (19 t 264 VAC) ...

Page 2

... Note: The input impedance is measured at the maximum value of the rated supply voltage (for example, with the model rated at 100 to 120 VAC, the input impedance is measured at 120 VAC). *With constant current input circuit system. The impedance for the G3NA-jjjB-UTU max. **Refer to the Engineering Data for further details. ...

Page 3

... Malfunction Hz, 1.5-mm double amplitude Shock resistance Malfunction: 1,000 m/s Ambient temperature Operating: – (with no icing or condensation) Storage: Approved standards UL508 File No. E64562/CSA C22.2 (No.0, No.14) File No. LR35535 (except for G3NA-450B) TÜV R9151660 (EN60950) (except for G3NA-4j0B) Ambient humidity Operating: 45% to 85% Weight Approx 158 G3NA-240B 1 ...

Page 4

... Y92B-N150) 20 With iron plate measuring 100 x 100 x 0 Without heat sink Ambient temperature ( C) G3NA G3NA-220B/420B With standard heat sink (Y92B-A100 or Y92B-N100) or alumi- num plate measuring 200 mm x 200 With iron plate measuring 100 x 100 x 0 Without heat sink Ambient temperature ( C) ...

Page 5

... SSR the graph shows that the heat sink 2 size is about 450 cm . Therefore, if the heat sink is square, one side of the heat sink must (15 G3NA G3NA-220B/420B Energizing time (ms) Temperature Characteristics (with Must Operate Voltage and Must Release Voltage) G3NA-2jjB AC Input Ambient temperature ( 450) or longer. ...

Page 6

... In the case of surface mounting, a 30% derating of the load current is required. The orientation indicated by the external dimensions is not the correct mounting orientation. When opening mounting holes, refer to the mount- ing hole dimensions. G3NA-205B, G3NA-210B, G3NA-220B, G3NA-410B, G3NA-420B 58 max. 47.5 44 G3NA-240B, G3NA-440B, G3NA-450B 58 min ...

Page 7

... Y92B-A250 Three, M4 holes 47.6 R2.2 50 0.1 56 0.5 150 max. Four, M4 190.5 max. 130.5 max. 70 max. G3NA Mounting Holes 35 0.2 75 max. Two, 4.4-dia holes 90 0.4 13 4.5 Weight: approx. 400 g Mounting Holes 35 0.2 Two, 4.4-dia. 104 max holes 90 0 ...

Page 8

... Load Connection For an AC load, use a power supply rated Hz. The maximum operating frequency is 10 Hz. The G3NA has a built-in varistor for overvoltage protection. Zero Cross Function An SSR with a zero cross function operates when an AC load volt- age reaches the zero point or its vicinity. This reduces clicking ...

Page 9

... G3NA When attaching a heat sink to the G3NA, apply Silicone Grease or equivalent heat conductive grease on the heat sink. (Toshiba Sili- con, Shinetsu Silicon, etc.) Tighten the mounting screws of the heat sink with a torque of 0. EN55011 Measurement of Mains Terminal Disturbance Voltage The G3NA-UTU conforms to EN55011 standards when a capacitor is connected to the load power supply as shown in the following cir- cuit diagram ...

Related keywords