LCA125 Clare, LCA125 Datasheet

RELAY OPTO 170MA SPST-NO 6-DIP

LCA125

Manufacturer Part Number
LCA125
Description
RELAY OPTO 170MA SPST-NO 6-DIP
Manufacturer
Clare
Series
LCA, OptoMOS®r
Datasheet

Specifications of LCA125

Circuit
SPST-NO (1 Form A)
Output Type
AC, DC
On-state Resistance
16 Ohm
Load Current
170mA
Voltage - Input
1.2VDC
Voltage - Load
0 ~ 350 V
Mounting Type
Through Hole
Termination Style
PC Pin
Package / Case
6-DIP (0.300", 7.62mm)
Load Voltage Rating
300 V
Load Current Rating
170 mA
Relay Type
Single Pole
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
CLA179

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LCA125
Quantity:
73
Part Number:
LCA125
Quantity:
5 510
Part Number:
LCA125
Manufacturer:
MICROCHIP
Quantity:
5 510
Part Number:
LCA125
Manufacturer:
CLARE
Quantity:
20 000
Part Number:
LCA125C
Quantity:
882
Part Number:
LCA125C
Manufacturer:
CLARE
Quantity:
356
Part Number:
LCA125CP
Manufacturer:
CPCIARE
Quantity:
20 000
Part Number:
LCA125STR
Manufacturer:
CPCLAER
Quantity:
20 000
Features
Applications
DS-LCA125-R8
Load Voltage
Load Current
Max R
Small 6 Pin DIP Package
Low Drive Power Requirements (TTL/CMOS
Compatible)
No Moving Parts
High Reliability
Arc-Free With No Snubbing Circuits
3750V
FCC Compatible
VDE Compatible
No EMI/RFI Generation
Machine Insertable, Wave Solderable
Surface Mount and Tape & Reel
Versions Available
Telecommunications
Instrumentation
Medical Equipment-Patient/Equipment Isolation
Security
Aerospace
Industrial Controls
Telecom Switching
Tip/Ring Circuits
Modem Switching (Laptop, Notebook, Pocket Size)
Hookswitch
Dial Pulsing
Ground Start
Ringer Injection
Multiplexers
Data Acquisition
Electronic Switching
I/O Subsystems
Meters (Watt-Hour, Water, Gas)
ON
RMS
Input/Output Isolation
LCA125
300
170
16
Units
mA
V
www.clare.com
Description
LCA125 is a 300V, 170mA, 16
tures enhanced peak load current capability with a 300V
peak load voltage. Current limiting version is available.
(“L” suffix)
Approvals
Ordering Information
Pin Configuration
LCA125/LCA125L Pinout
AC/DC Configuration
Do Not Use
LCA125
LCA125S
LCA125STR
Part #
+ Control
– Control
UL Recognized: File Number E76270
CSA Certified: File Number LR 43639-10
BSI Certified to:
BS EN 60950:1992 (BS7002:1992)
Certificate #: 7344
BS EN 41003:1993
Certificate #: 7344
1
2
3
Normally Open (Form A) Devices
Switching Characteristics of
Description
6 Pin DIP (50/Tube)
6 Pin Surface Mount (50/Tube)
6 Pin Surface Mount (1000/Reel)
6
5
4
Single Pole OptoMOS
Load
Do Not Use
Load
LCA125/125L Pinout
DC Only Configuration
Do Not Use
+ Control
– Control
1-Form-A relay. It fea-
1
2
3
LCA125
®
6
5
4
Relay
+ Load
– Load
1

Related parts for LCA125

LCA125 Summary of contents

Page 1

... Aerospace • Industrial Controls • DS-LCA125-R8 Single Pole OptoMOS Description Units LCA125 is a 300V, 170mA tures enhanced peak load current capability with a 300V mA peak load voltage. Current limiting version is available. (“L” suffix) Approvals • UL Recognized: File Number E76270 CSA Certified: File Number LR 43639-10 • ...

Page 2

... LCA125 Absolute Maximum Ratings (@ 25˚ C) Parameter Min Typ Max Units Input Power Dissipation - Input Control Current - Peak (10ms) - Reverse Input Voltage - Total Power Dissipation - Isolation Voltage Input to Output 3750 Operational Temperature -40 Storage Temperature -40 Soldering Temperature DIP Package - Surface Mount Package - (10 Seconds Max.) 1 Derate Linearly 1.33 mw/˚ ...

Page 3

... LCA125 Typical Blocking Voltage Distribution (N=50 Ambient Temperature = 302.5 311.5 320.5 338.5 338.5 347.5 Blocking Voltage (V) LCA125 Typical Turn-On Time (N=50 Ambient Temperature = 25 C) (Load Current = 170mADC 5mADC 0.875 1.225 1.575 1.925 2.275 2.625 2.975 Turn-On (ms) LCA125 Typical Leakage vs. Temperature (Measured across Pins 4 & ...

Page 4

... Temperature (Load Current = 170mADC) 1.800 1.600 1.400 1.200 1.000 0.800 0.600 0.400 0.200 0 100 -40 - 100 Temperature ( C) LCA125 Energy Rating Curve 1.2 1.0 0.8 0.6 0.4 0 100 s 1ms 10ms 100ms 1s 10s 100s Time www.clare.com LCA125 Typical Turn-Off vs. LED Forward Current (Load Current = 170mADC) 0 ...

Page 5

... Dimensions mm (inches) LCA125 .127 .005) 5 ...

Page 6

... Clare’s product may result in direct physical harm, injury, or death to a person or severe property or environmental damage. Clare, Inc. reserves the right to discontinue or make changes to its products at any time without notice. Specification: DS-LCA125-R8.0 ©Copyright 2002, Clare, Inc. ...