ASSR-1228-002E Avago Technologies US Inc., ASSR-1228-002E Datasheet - Page 10

no-image

ASSR-1228-002E

Manufacturer Part Number
ASSR-1228-002E
Description
RELAY SSR DPST 0.20A 8DIP
Manufacturer
Avago Technologies US Inc.
Series
ASSRr
Datasheet

Specifications of ASSR-1228-002E

Package / Case
8-DIP (0.300", 7.62mm)
Termination Style
PC Pin
Circuit
DPST (2 Form A)
Output Type
AC, DC
On-state Resistance
10 Ohm
Load Current
200mA
Voltage - Input
1.3VDC
Voltage - Load
0 ~ 60 V
Mounting Type
Through Hole
Control Voltage Range
0.8 V
Load Voltage Rating
60 V
Load Current Rating
0.2 A
Contact Form
2 Form A
Output Device
MOSFET
Case Color
Black
Input To Output Isolation Method
Optically Coupled Circuit
Relay Type
Solid State
Input Type
DC
Input Voltage (max)
1.6V
Output Voltage (max)
60V
Input Current (max)
25mA
Output Current
200mA
Isolation Voltage
3750(RMS)V
Circuit Arrangement
2 Form A
Package Type
PDIP
Pin Count
8
Mounting
Through Hole
Operating Temp Range
-40C to 85C
Operating Temperature Classification
Industrial
Rad Hardened
No
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ASSR-1228-002E
Manufacturer:
AVAGO
Quantity:
5 000
Part Number:
ASSR-1228-002E
Manufacturer:
AVAGO/安华高
Quantity:
20 000
Switching Specifications (AC)
For operating T
Notes:
1. For derating, refer to Figure 1, 2, 3 and 4.
2. The voltage across the output terminals of the relay should not exceed this rated withstand voltage. Over-voltage protection circuits should
3. Threshold to switch device is I
4. Device is considered as a two terminal device:
5. The Input-Output Momentary Withstand Voltage is a dielectric voltage rating that should not be interpreted as an input-output continuous
6. During the pulsed R
10
Parameter
Turn On Time
Turn Off Time
be added in some applications to protect against over-voltage transients.
I
voltage rating. For the continuous voltage rating refer to the IEC/EN/DIN EN 60747-5-2 Insulation Characteristics Table (if applicable), your
equipment level safety specification, or Avago Technologies Application Note 1074, “Optocoupler Input-Output Endurance Voltage. ”
F
=5mA.
ASSR-1218 - pin 1, 2 shorted and pin 3, 4 shorted.
ASSR-1219 - pin 1, 2, 3 shorted and pin 4, 5, 6 shorted.
ASSR-1228 - pin 1, 2, 3, 4 shorted and pin 5, 6, 7, 8 shorted.
A
= +25°C
(ON)
Sym.
T
T
measurement ( I
ON
OFF
F
≥ 0.5mA, however, for qualified device performance over temperature range, it is recommended to operate at
Min.
O
duration ≤30ms), ambient (T
Typ.
0.7
0.04
Max.
5.0
5.0
A
) and case temperature (T
Units
ms
ms
Conditions
I
I
F
F
=5mA, I
=5mA, I
C
O
O
) are equal.
=200mA
=200mA,
Fig.
Note