EZ240D5 Crydom Co., EZ240D5 Datasheet - Page 11

RELAY SSR 5A 240VAC AC OUT QC

EZ240D5

Manufacturer Part Number
EZ240D5
Description
RELAY SSR 5A 240VAC AC OUT QC
Manufacturer
Crydom Co.
Series
EZr
Datasheets

Specifications of EZ240D5

Load Current
5A
Circuit
SPST-NO (1 Form A)
Output Type
AC, Zero Cross
Voltage - Input
4 ~ 15VDC
Voltage - Load
24 ~ 280 V
Mounting Type
Chassis Mount
Termination Style
Quick Connect - .250" (6.3mm)
Package / Case
Module
Control Voltage Range
4Vdc To 15Vdc
Operating Voltage Range
24Vrms To 280Vrms
Isolation Voltage
4000V
Control Voltage Type
DC
Svhc
No SVHC (15-Dec-2010)
Blocking Voltage
600V
Control Current Typ
13mA
Relay Terminals
Quick Connect
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
On-state Resistance
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Two (Dual) or four (Quad) independent AC output relays come in a single standard
panel-mount package. Utilizing an AC switch output with internal snubber, relays
provide greater protection against false triggering. Model choices include zero
cross or random turn-on (phase controllable) switching (add suffix -10). For 24Vdc
Control (add suffix E). UL 508A SCCR Approved, consult Crydom for actual ratings.
Duals
D2425D
D2440D
H12D4825D 48-530
H12D4840D 48-530
Quads
TD2420Q
TD2420Q-10 24-280
Operating Temperature Range: -40˚C to 80˚C, Isolation Voltage: 4000 Vrms (Dual), 2500 Vrms (Quad)
Three-phase solid state relays switch up to 530 Vrms directly to loads such as
motors, transformers, heating elements, etc. Available with either AC or DC input
(coil) control in zero-voltage or random turn-on switching versions (add suffix -10).
For 24Vac Control (add suffix E).
D53TP25D
D53TP50D
D53DP25D
D53DP50D
A53TP25D
A53TP50D
A53DP25D
A53DP50D
* Current and Surge Ratings are per phase.
** DP is two controlled phases with the third connected straight through (A1 - A2).
Operating Temperature Range: 40˚C to 80˚C, Isolation Voltage: 4000 Vrms
**
**
**
**
Line
Voltage
Range
Vrms
24-280
24-280
Line
Voltage
Range
Vrms
24-280
Line
Voltage
Range
Vrms
48-530
48-530
48-530
48-530
Line
Voltage
Range
Vrms
48-530
48-530
48-530
48-530
Other Crydom products and competitive part number cross-reference available at: www.crydom.com
Load
Current
Range
.15-25
.15-40
.15-25
.15-40
Load
Current
Range
.15-20
.15-20
Load*
Current
Range
.05-25
.05-50
.05-25
.05-50
Load*
Current
Range
.05-25
.05-50
.05-25
.05-50
Arms
Arms
Arms
Arms
Dual Relays, Quad Relays
120/240/480 Vac
SCR AC Switch Output
Industry Standard Package
Zero Cross or Random Turn-On
Panel Mount Solid State Relays
Control
Voltage
Range
Vdc
4-15
4-15
4-15
4-15
Control
Voltage
Range
Vdc
4-15
4-15
Control
Voltage
Range
Vdc
3-32
3-32
4-32
4-32
Control
Voltage
Range
Vrms
90-280
90-280
90-280
90-280
53TP
25-50Amp 3 PHASE
120/240/480 Vac
SCR AC Switch Output
LED Status Indicator
Control
Current
@ 5Vdc
mA
13
13
13
13
Control
Current
@ 5Vdc
mA
12
12
Control
Current
@ 5Vdc
mA
10
10
20
20
Control
Current
@ 120Vrms Voltage
mA
2.2
2.2
5
5
Must
Release
Voltage
Vdc
1.0
1.0
1.0
1.0
Must
Release
Voltage
Vdc
1.0
1.0
Must
Release
Voltage
Vdc
1.0
1.0
1.0
1.0
Must
Release
Vrms
10.0
10.0
10.0
10.0
Surge
Current
1-Cycle
Apk
250
625
250
625
Surge
Current
1-Cycle
Apk
250
250
Surge*
Current
1-Cycle
Apk
250
625
250
625
Surge*
Current
1-Cycle
Apk
250
625
250
625
UL, CSA, VDE
UL, CSA, VDE
UL, cUL, VDE
UL, cUL, VDE
UL, CSA
UL, CSA
UL, CSA, VDE
UL, CSA, VDE
UL, cUL, VDE
UL, cUL, VDE
UL, CSA, VDE
UL, CSA, VDE
UL, cUL, VDE
UL, cUL, VDE
Output consists of an SCR AC switch turning on at the next peak of sinusoidal AC
wave form after the input has been activated. Continuing to conduct normally until
the input is deactivated and then turning off at the next current zero cross.
Suitable for switching transformers and other highly inductive loads where
significant inrush current may otherwise cause problems.
PSD2410
PSD2425
PSD2450
PSD2490
PSD4810
PSD4825
PSD4850
PSD4890
Operating Temperature Range: -40˚C to 80˚C, Isolation Voltage: 4000 Vrms, Minimum Off-State dv/dt: 500V/μsec
Panel Mount - DC Output
The DC60 products provide bipolar transistor DC output switching with high
(4000 Vrms) isolation voltage. Only Crydom offers AC input/DC output relays in this
economical standard panel-mount package.
DC60S3
DC60S5
DC60S7
DC60SA3
DC60SA5
DC60SA7
Operating Temperature Range: -30˚C to 80˚C Isolation Voltage:4000 Vrms
Normally closed (Form B) versions available (-B suffix)
Line
Voltage
Range
Vrms
90-280
90-280
90-280
90-280
48-530
48-530
48-530
48-530
Line
Voltage
Range
Vdc
3-60
3-60
3-60
Line
Voltage
Range
Vdc
3-60
3-60
3-60
Load
Current
Range
Arms
.04-10
.04-25
.04-50
.04-90
.04-10
.04-25
.04-50
.04-90
Load
Current
Range
Adc
.02-3
.02-5
.02-7
Load
Current
Range
Adc
.02-3
.02-5
.02-7
PSD
10-90Amp
120/240/480 Vac
Peak Switching
Internal Snubber
DC60
3-7Amp
60 Vdc
DC Bipolar Output
AC or DC Control
Economical Panel Mount Package
Control
Voltage
Range
Vdc
3-32
3-32
3-32
3-32
4-32
4-32
4-32
4-32
Control
Voltage
Range
Vdc
3.5-32
3.5-32
3.5-32
Control
Voltage
Range
Vrms
90-280
90-280
90-280
Control
Current
@5Vdc
mA
2.0
2.0
2.0
2.0
8
8
8
8
Control
Current
@ 5Vdc
mA
2.2
2.2
2.2
Control
Current
@120Vrms Voltage
mA
2
2
2
Must
Release
Voltage
Vdc
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
Must
Release
Voltage
Vdc
1.0
1.0
1.0
Must
Release
Vrms
10
10
10
Surge
Current
1-Cycle
Apk
120
250
625
1200
140
250
625
1200
Surge
Current
1 sec.
Adc
6
10
14
Surge
Current
1 sec.
Adc
6
10
14
UL, cUL
UL, cUL
UL, cUL
UL, cUL
UL, cUL
UL, cUL
UL, cUL
UL, cUL
UL, cUL
UL, cUL
11