3RHP6050G Crydom Co., 3RHP6050G Datasheet - Page 4

RELAY CONTACTOR 3PH 50A 600VAC

3RHP6050G

Manufacturer Part Number
3RHP6050G
Description
RELAY CONTACTOR 3PH 50A 600VAC
Manufacturer
Crydom Co.
Series
3RHPr
Datasheets

Specifications of 3RHP6050G

Load Current
50A
Circuit
3PST (3 Form A)
Output Type
AC
Voltage - Input
208 ~ 240VAC
Voltage - Load
48 ~ 600 V
Mounting Type
Chassis Mount
Termination Style
Screw Terminal, .250" QC
Package / Case
Module
Control Voltage Range
208VAC To 240VAC
Operating Voltage Range
48Vrms To 600Vrms
Isolation Voltage
4000Vrms
Control Voltage Type
AC
Relay Terminals
Quick Connect
Contact Form
3 - NO
Coil Voltage
208 V to 240 V
Contact Rating
50 A
Contact Termination
Screw
Mounting Style
Panel
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
On-state Resistance
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
RHP Series - Hybrid Solid State Contactors
Control Voltage Suffix
Coil Voltage Range
Min. Turn-On Voltage
Min. Turn-Off Voltage
Coil Power Consumption, Inrush
Coil Power Consumption, Sealed
C
Voltage suffix
Operating Voltage (50/60Hz)
Maximum Off-State Leakage Current per channel
Load Current suffix
Maximum Load Current per Phase @ 40°C
Power terminals / wire range
S
Input to Output Dielectric Isolation.
Input/Output to Ground Dielectric Isolation.
Contacts (Double Break )
Ambient Operating Temperature Range
Ambient Storage Temperature Range
Max. Turn-On Time
Max. Turn-Off Time
Maximum Number of Operations per Minute
Lifetime @ Rated Load Current, 40°C ambient
temp, 30 operations/min, Rated Vcontrol
Weight (typical)
r c
l i o
w e
Specificationts @ 25°C unless otherwise noted.
See Derating Curves for additional operational conditions.
The RHP includes a Solid-State Relay. Therefore, the output is never completely open.
The RHP includes an overtemperature protection for the Solid-State Module.
e T
m r
o t
q r
n i
e u
s l a
e r
u q
3RHP2840E
3RHP2840F
3RHP2840G
3RHP2850E
3RHP2850F
3RHP2850G
3RHP6040E
3RHP6040F
3RHP6040G
3RHP6050E
3RHP6050F
3RHP6050G
e r i
m
n e
s t
Questions? Call or e-mail
20 - 26 VAC, 50/60 Hz
6.6 VA @ 24 VAC
56 VA @ 24 VAC
0 1
VAC 50/60 Hz
Operating
n i
Voltage
24-280
24-280
24-280
24-280
24-280
24-280
48-600
48-600
48-600
48-600
48-600
48-600
20 VAC
12 VAC
b l
. 1 (
3 Phase Contactor
AC Input
40-50 Amp
280/600 VAC
head screws / AWG#14 - AWG#8
3 1
Dual quick connect and Binder
N
15-18 in lbs (1.7-2.1 Nm)
Combined SSR and EMR advantages
Lifetime >2 million operations @ full load
No heat sink required
Input status LED indicator
Wire, lug or quick connect termination
DP contactor footprint
CE compliant, UL/cUL recognized
100k-cycle UL508 endurance rating
) m
0.05 mA @ 240 VAC
40 A Resistive
Amps rms
24 - 280 VAC
Current
100 - 130 VAC, 50/60 Hz
Load
40
40
40
50
50
50
40
40
40
50
50
50
6.6 VA @ 120 VAC
56 VA @ 120 VAC
0 1
16.6 mS @ 60 Hz / 20 mS @ 50 Hz
n i
32 mS @ 60 Hz / 40 mS @ 50 Hz
100 VAC
24 VAC
b l
. 1 (
Three Normally Open
30 operations per min
> 2 Million operations
3 1
-40°C to 100°C
540 grs (1.19 lb)
-20°C to 75°C
VAC 60 Hz
20-26
100-130
208-240
20-26
100-130
208-240
20-26
100-130
208-240
20-26
100-130
208-240
N
Voltage
Control
4000 VAC
2500 VAC
) m
Dual quick connect and Box
lugs / AWG#14 - AWG#6
20-25 in lbs (2.2-2.9 Nm)
Europe
Americas
0.06 mA @ 480 VAC
208 - 240 VAC, 50/60 Hz
50 A Resistive
6.6 VA @ 220 VAC
48 - 600 VAC
56 VA @ 220 VAC
0 1
n i
208 VAC
48 VAC
b l
. 1 (
3 1
+44 (0) 1202 606030
N
+1 (877) 502 5500
) m
Control Voltage Suffix
Control Voltage Range
Max. Reverse Voltage
Min. Turn-On Voltage
Min. Turn-Off Voltage
Input Current
Input Connector
Voltage suffix
Operating Voltage (50/60Hz)
Maximum Off-State Leakage Current per channel
Load Current suffix
Maximum Load Current per Phase @ 40°C
Power terminals / wire range
S
Input to Output Dielectric Isolation
Input/Output to Ground Dielectric Isolation
Contacts (Double Break)
Ambient Operating Temperature Range
Ambient Storage Temperature Range
Max. Turn-On Time
Max. Turn-Off Time
Maximum Number of Operations per Minute
Lifetime @ Rated Load Current, 40°C ambient
temp, 30 operations/min, Rated Vcontrol
Weight (typical)
r c
w e
Specificationts @ 25°C unless otherwise noted.
See Derating Curves for additional operational conditions.
The RHP includes a Solid-State Relay. Therefore, the output is never completely open.
The RHP includes an overtemperature protection for the Solid-State Module.
o t
q r
e u
e r
u q
3RHP1240D12
3RHP1240D24
3RHP1240D5
3RHP1250D12
3RHP1250D24
3RHP1250D5
3RHP2440D12
3RHP2440D24
3RHP2440D5
3RHP2450D12
3RHP2450D24
3RHP2450D5
e r i
m
n e
sales-europe@crydom.com
sales@crydom.com
s t
VAC 50/60 Hz
Operating
. 5
100-120
100-120
100-120
100-120
100-120
100-120
208-240
208-240
208-240
208-240
208-240
208-240
Voltage
12mA @ 5 VDC
1 3
4.5 - 5.5 VDC
-5.5 VDC
4.5 VDC
n i
head screws / AWG#14 - AWG#8
1 VDC
Dual quick connect and Binder
b l
15-18 in lbs (1.7-2.1 Nm)
0 (
6 .
3 Phase Contactor
DC Input
40-50 Amp
120/240 VAC
0.05 mA @ 120 VAC
N
100 - 120 VAC
40 A Resistive
) m
Combined SSR and EMR advantages
Lifetime >2 million operations @ full load
No heat sink required
DC logic compatible input
Input status LED indicator
Wire, lug or quick connect termination
DP contactor footprint
CE compliant, UL/cUL recognized
100k-cycle UL508 endurance rating
16.6 mS @ 60 Hz / 20 mS @ 50 Hz
Amps rms
32 mS @ 60 Hz / 40 mS @ 50 Hz
Current
Load
40
40
40
50
50
50
40
40
40
50
50
50
. 5
30 operations per min
Three Normally Open
> 2 Million operations
12mA @ 12 VDC
1 3
540 grs (1.19 lb)
10 - 15 VDC
-40°C to 100°C
-15.5 VDC
-20°C to 75°C
9.5 VDC
n i
2 VDC
4000 VAC
2500 VAC
b l
0 (
6 .
N
10-15
22-27
4.5-5.5
10-15
22-27
4.5-5.5
10-15
22-27
4.5-5.5
10-15
22-27
4.5-5.5
Voltage
Control
) m
Dual quick connect and Box
VDC
20-25 in lbs (2.2-2.9 Nm)
lugs / AWG#14 - AWG#6
0.06 mA @ 240 VAC
208 - 240 VAC
50 A Resistive
. 5
12mA @ 24 VDC
1 3
22 - 27 VDC
-27.5 VDC
n i
9.5 VDC
2 VDC
b l
0 (
6 .
N
) m