PLA143STR Clare, PLA143STR Datasheet

RELAY OPTOMOS 100MA SP-NO 6-SMD

PLA143STR

Manufacturer Part Number
PLA143STR
Description
RELAY OPTOMOS 100MA SP-NO 6-SMD
Manufacturer
Clare
Series
PLA, OptoMOS®r
Datasheet

Specifications of PLA143STR

Circuit
SPST-NO (1 Form A)
Output Type
AC, DC
On-state Resistance
50 Ohm
Load Current
100mA
Voltage - Input
1.2VDC
Voltage - Load
0 ~ 600 V
Mounting Type
Surface Mount
Termination Style
Gull Wing
Package / Case
6-SMD (300 mil)
Load Voltage Rating
600 V
Load Current Rating
100 mA
Mounting Style
SMD/SMT
Relay Type
Single Pole
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
DS-PLA143-R06
Features
Applications
Parameters
Blocking Voltage
Load Current
Max On-resistance
Instrumentation
Medical Equipment—Patient/Equipment Isolation
Security
Aerospace
Industrial Controls
Small 6-Pin Package
Low Drive Power Requirements (TTL/CMOS
Compatible)
No Moving Parts
High Reliability
Arc-Free With No Snubbing Circuits
4000V
FCC Compatible
VDE Compatible
No EMI/RFI Generation
Machine Insertable, Wave Solderable
600 Volt blocking
Multiplexers
Data Acquisition
Electronic Switching
I/O Subsystems
Meters (Watt-Hour, Water, Gas)
rms
2002/95/EC
RoHS
Input/Output Isolation
e
3
Ratings
600
100
50
Units
mA
V
P
www.clare.com
PLA143 Pinout
AC/DC Configuration
Description
Approvals
Ordering Information
Pin Configuration
The PLA143 is a 1-Form-A solid state relay which
uses optically coupled MOSFET technology to
provide an enhanced input to output isolation of
4000V
photovoltaic die use Clare’s patented OptoMOS
architecture. The optically-coupled output is controlled
by a highly efficient GaAIAs infrared LED. The
PLA143 can be used to replace mechanical relays
and offers the superior reliability associated with
semiconductor devices. Because they have no
moving parts, they can offer faster, bounce-free
switching in a more compact surface mount or
through hole package.
Part #
PLA143
PLA143S
PLA143STR
+ Control
– Control
UL Recognized: File Number E76270
CSA Certified: File Number LR 43639-10
BSI Certified to:
BS EN 60950:1992 (BS7002:1992)
Certificate #: 7344 (to 3750 volts)
BS EN 41003:1993
Certificate #: 7344
NC
rms
1
2
3
. The efficient MOSFET switches and
Single Pole OptoMOS
Normally Open (Form A) Devices
Switching Characteristics of
CONTROL
LOAD
Description
6-Pin DIP (50/Tube)
6-Pin Surface Mount (50/Tube)
6-Pin Surface Mount (1000/Reel)
6
5
4
Load
Do Not Use
Load
10%
+
+
90%
T
PLA143 Pinout
DC Only Configuration
ON
+ Control
– Control
T
OFF
10%
NC
+
1
2
3
PLA143
®
Relay
6
5
4
®
+ Load
– Load
1

Related parts for PLA143STR

PLA143STR Summary of contents

Page 1

... CSA Certified: File Number LR 43639-10 • BSI Certified to: • • 60950:1992 (BS7002:1992) Certificate #: 7344 (to 3750 volts) • 41003:1993 Certificate #: 7344 Ordering Information Part # PLA143 PLA143S PLA143STR Pin Configuration PLA143 Pinout AC/DC Configuration 1 + Control 2 – Control 3 NC Normally Open (Form A) Devices www.clare.com PLA143 ® ...

Page 2

... Conditions Symbol - 10ms I LPK I =100mA =170mA =600V I L LEAK I =5mA, V =10V =5mA, V =10V OFF 50V; f=1MHz C OUT I =90mA =5mA = I/O www.clare.com Min Typ Max Units - - 100 170 350 Ω Ω µ 0.2 0. 0.9 1.2 1 µ R06 ...

Page 3

... I = 5mA 1.5 F 1.0 0 10mA 0 F -40 - 100 Temperature (°C) www.clare.com PLA143 PLA143 Typical Blocking Voltage Distribution (N=50 Ambient Temperature = 25° 777 782 787 792 797 802 807 Blocking Voltage ( PLA143 Typical Turn-On Time (N=50 Ambient Temperature = 25°C) (Load Current = 100mA ...

Page 4

... Energy Rating Curve 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 10µs 100µs 1ms 10ms 100ms 1s 10s 100s Time www.clare.com PLA143 Typical Turn-Off vs. LED Forward Current (Load Current = 100mA ) DC 0.7 0.6 0.5 0.4 0.3 0.2 0 LED Forward Current (mA) ...

Page 5

... Recommended soldering processes are limited to 260ºC component body temperature for 10 seconds. R06 Washing Clare does not recommend ultrasonic cleaning or the use of chlorinated solvents. www.clare.com PLA143 e 3 RoHS ...

Page 6

... The products described in this document are not designed, intended, authorized or warranted for use as components in systems intended for surgical implant into the body other applications intended to support or sustain life, or where malfunction of Clare’s product may result in direct physical harm, injury, or death to a person or severe property or environmental damage. Clare, Inc. reserves the right to discontinue or make changes to its products at any time without notice ...