LCA220 Clare, LCA220 Datasheet

RELAY OPTO 120MA DP-NO 8-DIP

LCA220

Manufacturer Part Number
LCA220
Description
RELAY OPTO 120MA DP-NO 8-DIP
Manufacturer
Clare
Series
LCA, OptoMOS®r
Datasheet

Specifications of LCA220

Circuit
DPST (2 Form A)
Output Type
AC, DC
On-state Resistance
20 Ohm
Load Current
120mA
Voltage - Input
1.2VDC
Voltage - Load
0 ~ 250 V
Mounting Type
Through Hole
Termination Style
PC Pin
Package / Case
8-DIP (0.300", 7.62mm)
Load Voltage Rating
250 V
Load Current Rating
120 mA
Relay Type
Common
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LCA220
Quantity:
144
Part Number:
LCA220
Manufacturer:
WS
Quantity:
5 000
Part Number:
LCA220CP
Quantity:
5 510
Part Number:
LCA220CP
Quantity:
5 510
DS-LCA220-R6
Features
Applications
Load Voltage
Load Current
Max R
Telecommunications
Instrumentation
Security
Aerospace
Industrial Controls
Small 8 Pin DIP Package
Low Drive Power Requirements (TTL/CMOS
Compatible)
No Moving Parts
High Reliability
Arc-Free With No Snubbing Circuits
3750V
FCC Compatible
VDE Compatible
No EMI/RFI Generation
Machine Insertable, Wave Solderable
Surface Mount and Tape & Reel Versions Available
Telecom Switching
Tip/Ring Circuits
Modem Switching (Laptop, Notebook, Pocket Size)
Hookswitch
Dial Pulsing
Ground Start
Ringer Injection
Multiplexers
Data Acquisition
Electronic Switching
I/O Subsystems
Meters (Watt-Hour, Water, Gas)
Medical Equipment-Patient/Equipment Isolation
ON
RMS
Input/Output Isolation
LCA220
250
120
20
Units
mA
V
www.clare.com
Description
LCA220 is a common input 1- Form 2A solid state relay
which has two independent optically couple MOSFETs
controlled by a common input signal. The efficient MOS-
FET switches and photovoltaic die use Clare’s patented
OptoMOS architecture to provide 3750 V
output isolation. The optically coupled input is controlled
by highly efficient GaAIAs infrared LEDs. Common input
OptoMOS relays can replace standard dual pole relays in
a variety of applications. The common input relay elimi-
nates the need to make an external circuit connection
when both poles are controlled by a common signal.
Approvals
Pin Configuration
Ordering Information
LCA220
LCA220S
LCA220STR
Part #
UL Recognized: File Number E76270
CSA Certified: File Number LR 43639-10
BSI Certified to:
BS EN 60950:1992 (BS7002:1992)
Certificate #: 7344
BS EN 41003:1993
Certificate #: 7344
LCA220 Pinout
Commom Input OptoMOS
Description
8 Pin DIP (50/Tube)
8 Pin Surface Mount (50/Tube)
8 Pin Surface Mount (1,000/Reel)
Normally Open (Form A) Devices
Switching Characteristics of
RMS
LCA220
®
of input to
Relays
1

Related parts for LCA220

LCA220 Summary of contents

Page 1

... Industrial Controls • DS-LCA220-R6 Commom Input OptoMOS Description Units LCA220 is a common input 1- Form 2A solid state relay V which has two independent optically couple MOSFETs mA controlled by a common input signal. The efficient MOS- FET switches and photovoltaic die use Clare’s patented OptoMOS architecture to provide 3750 V output isolation ...

Page 2

... LCA220 Absolute Maximum Ratings (@ 25˚ C) Parameter Min Typ Max Units Input Power Dissipation - Input Control Current - Peak (10ms) - Reverse Input Voltage - Total Power Dissipation - Isolation Voltage Input to Output 3750 Operational Temperature -40 Storage Temperature -40 Soldering Temperature DIP Package - Flatpack/Surface Mount Package - (10 Seconds Max.) 1 Derate Linearly 1.33 mw/˚ ...

Page 3

... Typical Load Current vs. Temperature Temperature ( C) LCA220 Typical Turn-On vs. Temperature (Load Current = 80mADC) 10mA 20mA Temperature ( C) www.clare.com LCA220 LCA220 Typical Blocking Voltage Distribution (N=50 Ambient Temperature = 25 C) Blocking Voltage (V) LCA220 Typical Turn-On Time (N=50 Ambient Temperature = 25 C) (Load Current = 120mADC 10mADC) F Turn-On (ms) LCA220 Typical Leakage vs ...

Page 4

... Typical Turn-On vs. LED Forward Current (Load Current = 120mADC) LED Forward Current (mA) LCA220 Typical I for Switch Operation F vs. Temperature (Load Current = max rated over temp) Temperature ( C) LCA220 Energy Rating Curve Time www.clare.com LCA220 Typical Turn-Off vs. LED Forward Current (Load Current = 120mADC) LED Forward Current (mA) LCA220 Typical I ...

Page 5

... Dimensions mm (inches) LCA220 5 ...

Page 6

... Clare’s product may result in direct physical harm, injury, or death to a person or severe property or environmental damage. Clare, Inc. reserves the right to discontinue or make changes to its products at any time without notice. Specification: DS-LCA220-R6.0 ©Copyright 2002, Clare, Inc. ...

Related keywords