PD2401 Clare, PD2401 Datasheet
PD2401
Specifications of PD2401
PD2401
Q1161250
Available stocks
Related parts for PD2401
PD2401 Summary of contents
Page 1
... Motors • Heaters RoHS 2002/95/EC DS-PD2401-R12 Description Units The PD2401 Solid State Switch using optical V rms coupling with dual power SCR outputs to produce an A rms alternative to optocoupler and Triac circuits. The V rms PD2401 switches are robust enough to provide a blocking voltage 500V current rating of 20A ...
Page 2
... Conditions Symbol I =5mA =120-240VAC t<16ms I PEAK V =500V LEAK I =1. rms - dV/ =5mA F t off st 1 half-cycle - Subsequent half-cycle - - - I =5mA = www.clare.com PD2401 Min Typ Max Units 20 - 240 V 0.005 - 1.2 V 1000 1200 - V/µ 0.5 Cycles - - 0 500 0. 0.9 1.2 1.4 0 rms rms A ...
Page 3
... NOTE: Values apply to T =50ºC before Surge Pulse Duration (ms) PD2401 dV/dt Method 300V 63% dV 0.63 x 300V 189 = = accordance with EIA/NARM Standards 10% RS-443 for Solid State Relays 85 RC www.clare.com PD2401 PD2401 Typical Forward Voltage vs. Temperature 1.3 1.2 1.1 1.0 0.9 100 Ambient Temperature (º ...
Page 4
... Chlorine- or Fluorine-based solvents or fluxes should not be used. Cleaning methods that employ ultrasonic energy should not be used RoHS 3 2002/95/EC 4 Moisture Sensitivity Level (MSL) Rating MSL 1 Maximum Temperature x Time 245ºC for 30 seconds www.clare.com PD2401 R12 ...
Page 5