88826103 Crouzet USA, 88826103 Datasheet

RELAY TIME ANALG 10A 12-240V DIN

88826103

Manufacturer Part Number
88826103
Description
RELAY TIME ANALG 10A 12-240V DIN
Manufacturer
Crouzet USA
Series
MUR3r
Datasheets

Specifications of 88826103

Mounting Type
DIN Rail
Relay Type
Integrated
Function
Programmable (Multi-Function)
Circuit
SPDT (1 Form C)
Delay Time
0.1 Sec ~ 100 Hrs
Output Type
Mechanical Relay
Contact Rating @ Voltage
10A @ 250VAC
Voltage - Supply
12 ~ 240VAC/DC
Termination Style
Screw Terminal
Timing Adjustment Method
Screwdriver Slot
Timing Initiate Method
Input Voltage, Trigger Signal
Contact Current Max
10A
Time Range
0.1s To 100h
Controller Features
Multifunction
Supply Voltage Max
280VAC
Supply Voltage Min
10VAC
Contact Form
SPDT
Current, Rating
10 A
Display Type
LED indicator
Power, Rating
2000⁄80 VA⁄W
Standards
UL, cUL, CSA, CE
Temperature, Operating, Maximum
60 °C
Temperature, Operating, Minimum
-20 °C
Termination
Screw
Timer Type
Multi-Function
Timing Range
0.1 to 1 sec., 1 to 10 sec., 10 sec. to 1 min., 1 to 10 min., 10 min. to 1 hr., 1 to 10 hrs., 10 to 100 hrs.
Voltage, Control
240 VAC⁄VDC
Voltage, Rating
250 V
Supply Voltage
12 V to 240 V
Contact Rating
10 A at 250 VAC
Controller Output
Relay
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
646-1179
88826103-MUR3
4-18
Chronos 2 electronic timers - 17.5 mm
For special features, functions etc. please contact us.
Technical specifications
Timing
Repetition accuracy (with constant
parameters)
Drift
- Temperature
- Voltage
Display precision according to IEC 1812-1
Minimum pulse duration
- Typically (relay version)
- Typically (solid state version)
- Typically under load (relay version)
Maximum reset time by de-energisation
- Typically (relay version)
- Typically (solid state version)
Immunity to breaks in supply voltage: typically
Power supply
Multi-voltage power supply
Frequency
Operating range
Load factor
Maximum power consumption
Output elements relay output
1 or 2 changeover relays, AgNi (cadmium-free)
Rated power
Maximum breaking current
Minimum breaking current
Voltage breaking capacity
Electrical life
Mechanical life
Breakdown voltage acc. to IEC 1812-1
Impulse voltage acc. to IEC 664-1 IEC 1812-1
Display
State displayed by 1 LED
- Flashing green when on
Green LED operation indicator
- timer on, no timing in progress
- timing in progress
- Relay waiting, no timing in progress
Input type
- Volt-free contact
- 3-wire PNP output control option maximum
residual voltage: 0.4 V whatever the timer
power supply
(except functions Di-D and Li-L)
Multi-function or mono-function
Multi-range
Multi-voltage
SPDT relay output: 10A - 250V
Screw or spring terminals
1 LED status indicator
Option of connecting a small cord to the
control input
3-wire sensor control option
204 Airline Drive, Suite 300, Coppell, Texas 75019 / Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com
Pulsing:
Flashing:
Permanently lit:
(
7 ranges, available options
Other information
Products and specifications subject to change without notice.
Consult factory for application assistance.
± 0.5 %
(CEI 1812-1)
± 0.05 % / °C
± 0.2 % / V
±10 % / 25 °C
30 ms
50 ms
100 ms
100 ms
350 ms
>10 ms
depending on version,
see pages 6/2, 6/3
50/60 Hz
85 to 110 % Un
(85 to 120 % Un for
12V AC/DC)
100 %
0.6 W 24V AC/DC
1.5 W 230V AC
32 VA 230V AC
2000 VA / 80 W
2000 V A / 80W
10 A AC 10 A DC
10 mA / 5 VDC
250V AC/VDC
10
8 A 250V resistive
5 x 10
2.5 kV / 1min /
1 mA /50Hz
5 kV, wave 1.2 / 50 µs
0.4 V
)
5
operations
6
operations
Timing
Types
Screw terminals
Spring terminals
Part numbers and voltage
24V c / 24 • 240V a
12 V a / c
12 • 240 V a / c
Functions
Nominal current
Timing ranges
1s - 10 s - 1 min - 10 min - 1 h - 10 h - 100 h
General specifications
Conforming to standards
IEC 1812-1, EN 50081-1/2, EN 50082-1/2, LV
directives (73/23/EEC + 93/68/EEC
(CE marking) + EMC (89/336/EEC +
IEC 669-2-3 (17.5 mm)
Approvals
cUL listed
Temperatures limits
- use
- stored
Installation category (acc. to IEC 664-1)
Creepage distance and clearance acc. to
IEC 664-1
Degree of protection acc. to IEC 529
- terminal block
- casing
- front face (except Tk2R1)
Vibration resistance acc. to IEC 68-2-6
Relative humidity acc. to IEC 68-2-3
without condensation
Electromagnetic compatibility
- Immunity to electrostatic discharges acc. to
IEC 1000-42
- Immunity to electrostatic fields acc. to
ENV 50140/204 (IEC 1000-4-3)
- Immunity to rapid transient bursts acc. to IEC
1000-4-4
- Immunity to shock waves on power supply
acc. to IEC 1000-4-5
- Immunity to radiofrequency in common mode
acc. to ENV
- Immunity to voltage dips and breaks acc. to
IEC 1000-4-11
- Mains-borne and radiated emissions acc. to
EN 55022 (EN 55011 Group 1)
Fixing: Symmetrical DIN rail (EN 50022)
Connection capacity
- without ferrule
- with ferrule
Spring terminals, 2 terminals per connection point
- flexible wire
- rigid wire
Casing material
Weight: 17.5 mm casing
UL listed
(7 ranges)
CSA recognized
0.1s • 100h
MUR1
88 826 105
Multi-function
A - At - B - C - H - Ht -
Di - D - Ac - Bw
10 A
-
-
-
0.1s • 100h
MAR1
88 826 115
Bifunction
A - At
10 A
-20 °C + 60 °C
-30 °C + 60 °C
Voltage surge
category
4 kV / 3
IP 20
IP 40
IP 50
f = 10 • 55 Hz
A = 0.35 mm
93 %
Level III
(Air 8 K /
Contact 6 KV)
Level III 10V/m:
80 MHz to 1 GHz)
Level III (direct 2kV/
Capacitive coupling
clamp 1 KV)
Level III (common
mode 2 KV / residual
current mode 1KV)
Level III (10V rms:
0.15 MHz to 80 MHz)
30 % / 10 ms
60 % / 100 ms >
95 % / 5 s
Class B
35 mm
2 x 2.5 mm
2 x 1.5 mm
1.5 mm
2.5 mm
Self-extinguishing
60 g
2
2
-
-
-
2
2

Related parts for 88826103

88826103 Summary of contents

Page 1

... Power supply Multi-voltage power supply Frequency Operating range Load factor Maximum power consumption Output elements relay output changeover relays, AgNi (cadmium-free) Rated power Maximum breaking current Minimum breaking current Voltage breaking capacity Electrical life Mechanical life Breakdown voltage acc. to IEC 1812-1 Impulse voltage acc ...

Page 2

MBR1 MCR1 - - 88 826 125 88 826 135 - - - - Mono-function Mono-function Function diagrams Function A Function H Delay on Make Interval 1 relay ...

Page 3

Chronos 2 electronic timers - 17.5 mm Solid state output Multi-function or mono-function ■ Multi-range (7 ranges, available options) ■ Multi-voltage ■ Solid state output: 0 250 V (0.5 A UL) ■ Screw or spring terminals ■ 1 ...

Page 4

MUS2 MAS5 88 826 004 - - 88 826 014 Multi-function Mono-function 0.7 A, ...

Related keywords