H3DE-H AC100-120 L Omron, H3DE-H AC100-120 L Datasheet - Page 27

no-image

H3DE-H AC100-120 L

Manufacturer Part Number
H3DE-H AC100-120 L
Description
TIMER 22.5MM 1-120S DIN MNT
Manufacturer
Omron
Series
H3DE-Hr
Datasheet

Specifications of H3DE-H AC100-120 L

Relay Type
Integrated
Function
Off-Delay
Circuit
SPDT (1 Form C)
Delay Time
1 Sec ~ 120 Sec
Output Type
Mechanical Relay
Contact Rating @ Voltage
5A @ 250VAC
Voltage - Supply
100 ~ 120VAC
Mounting Type
DIN Rail
Termination Style
Screw Terminal
Timing Adjustment Method
Screwdriver Slot
Timing Initiate Method
Input Voltage
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
H3DE-HAC100-120L
H3DEHAC100120L
Connections
■ Block Diagram
■ I/O Functions
■ Terminal Arrangement
Note: DC supply voltage does not require the designation of polarity.
Inputs
Outputs
Control output
AC (DC) input
Power supply
circuit
Power failure
detection circuit
---
The Timer operates instantaneously when the Timer is turned ON. The Timer is in counting operation
after the Timer is turned OFF and the output of the Timer is turned OFF when the preset time elapses.
Indicator
circuit
Oscillation
circuit
(DIN notation)
A1
A2
16
15
18
Time scale
selector
Counting
circuit
Output
circuit
H3DE-H
27