H2C AC240 A Omron, H2C AC240 A Datasheet

no-image

H2C AC240 A

Manufacturer Part Number
H2C AC240 A
Description
MOTOR TIMER 11PIN SOCKET 240V
Manufacturer
Omron
Series
H2Cr
Datasheets

Specifications of H2C AC240 A

Relay Type
Integrated
Function
Motor Timer
Circuit
SPDT (1 Form C)
Delay Time
1.25 Sec ~ 30 Hrs
Output Type
Mechanical Relay
Contact Rating @ Voltage
6A @ 250VAC
Voltage - Supply
240VAC
Mounting Type
Socket
Termination Style
11 Pin Socketable
Timing Adjustment Method
Hand Dial
Timing Initiate Method
Input Voltage
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
H2CAC240A
DIN-sized 48 x 48 Motor Timer with Simple
Operation for Switching Time Specifications
• Three Motor Timers cover the wide time range of 6 s to 30 h with
• Five time specifications for each model with linked time display.
• DIN-standard size of 48 x 48 mm.
• Easily check operation with neon lamp.
• Models with sockets and models with top wiring are also avail-
• Certified for UL and CSA safety standards.
• Conforms to EN 61812-1 (except models that end with “-F”) and
Model Number Structure
■ Model Number Legend
1. External Connection/Attachment
Ordering Information
■ List of Models
H2C-@ @
Note: Specify both the supply voltage and time range code (A, B, or C) in addition to the model number when ordering.
Time-limit operation/
self-resetting
Time-limit operation/
electric resetting
easy operation from the operation panel.
able.
CE Marking.
Operation/resetting
Motor Timer
H2C
None: 11-pin socket
S:
8:
F:
Example: H2C-S 24 VAC B
system
1
11-pin socket/time setting ring
8-pin socket
Front screw
2
Parallel motor and
clutch connection
Separate motor
and clutch
connection
connection
Internal
Time range code
Supply voltage
8-pin socket
11-pin socket
Front screw
8-pin socket
11-pin socket
Front screw
Terminal
SPDT
SPDT
Time-limit
contact
2. Operation/Resetting System
None: Time-limit operation/self-resetting
R:
SPDT
---
SPDT
Instantaneous
Time-limit operation/electric resetting
contact
---
Y92A-Y1 Time
Setting Ring
---
---
Y92A-Y1 Time
Setting Ring
---
Attachment
H2C-8
H2C
H2C-S
H2C-F
H2C-8R
H2C-R
H2C-SR
H2C-FR
CSM_H2C_DS_E_2_1
Model
1

Related parts for H2C AC240 A

H2C AC240 A Summary of contents

Page 1

Motor Timer H2C DIN-sized Motor Timer with Simple Operation for Switching Time Specifications • Three Motor Timers cover the wide time range with easy operation from the operation panel. • Five ...

Page 2

Accessories (Order Separately) Name/specifications Flush Mounting Adapter Time Setting Ring (See note 1 (l) × 7.3 mm (t) Mounting Track 1 m (l) × 7 (l) × (t) End Plate Spacer ...

Page 3

Characteristics ±0.5% FS max. 〈±1% max for the time range code 0 for the time range Accuracy of operating time code C) ±2% FS max. Setting error Reset ...

Page 4

Connections ■ Terminal Arrangement Note: The connections diagrams are for when the clutch is in the excited, reset state. H2C-8 H2C(-F)/H2C-S Clutch coil 6 (B2) (B1 (B2) (16) (22) (B1) 8 (16) (18) 4 (24) (22) (18) (A1) ...

Page 5

Operation ■ Timing Chart H2C Power (2-7) Time-limit contacts NC (8-5) Time-limit contacts NO (8-6) Instantaneous contacts NC (1-4) Instantaneous contacts NO (1-3) Timing operation indicator lamp (OFF at time-up) H2C(-F)/H2C Power and motor 2(A1)-10(A2) Power ...

Page 6

Dimensions Note: All units are in millimeters unless otherwise indicated. H2C/H2C-S/H2C-R/H2C-SR/H2C-8/H2C-8R H2C-F/H2C-FR Dimensions with Front Connecting Socket P2CF-08-@/P2CF-11-@ H2C H2C-S H2C 103.1 100.8 H2C-SR P2CF-11 P2CF-11-E P2CF-08-E * These dimensions vary with the kind of DIN track (reference ...

Page 7

Accessories (Order Separately) Adapter for Flush Mounting Y92F-30 Track Mounting/Front Connecting Socket P2CF-08 Eight, M3.5 x 7.5 sems 70 max max. P2CF-08-E (Finger Safe Terminal Type) Conforming to VDE0106/P100 Eight, M3.5 x 7.5 sems 70 max. 4 ...

Page 8

Track Mounting/Front Connecting Socket P2CF-11 Eleven, M3.5 x 7.5 sems 70 max max. P2CF-11-E (Finger Safe Terminal Type) Conforming to VDE0106/P100 Eleven, M3.5 x 7.5 sems 70 max. 4 40±0.2 50 max. Back Connecting Socket P3G-08 27 dia. ...

Page 9

Mounting Track PFP-100N, PFP-50N 4 ( 1,000 (500) (see note) (see note) Note: The value shown in parentheses are for the PFP-50N. End Plate PFP pan ...

Page 10

... Leaving the H2C with outputs high temperature for a long time may hasten the degradation of internal parts (such as electrolytic capacitors). Therefore, use the H2C in combination with relays and avoid leaving the H2C for more than 1 month with an output turned ON ...

Page 11

Others Do not turn the operation time setting knob beyond the range of the scale. To achieve higher accuracy in setting, measure the operation time while turning the operation time setting knob. The deviation and setting error for the operation ...

Page 12

... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...

Related keywords