H2C-8R AC100/110 C Omron, H2C-8R AC100/110 C Datasheet - Page 3

no-image

H2C-8R AC100/110 C

Manufacturer Part Number
H2C-8R AC100/110 C
Description
MOTOR TIMER 8PIN SOCKET 100-110V
Manufacturer
Omron
Series
H2Cr
Datasheets

Specifications of H2C-8R AC100/110 C

Relay Type
Integrated
Function
Motor Timer
Circuit
SPDT (1 Form C)
Delay Time
0.5 Sec ~ 12 Hrs
Output Type
Mechanical Relay
Contact Rating @ Voltage
6A @ 250VAC
Voltage - Supply
100 ~ 110VAC
Mounting Type
Socket
Termination Style
8 Pin Socketable
Timing Adjustment Method
Hand Dial
Timing Initiate Method
Input Voltage
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
H2C-8RAC100/110C
H2C8RAC100110C
■ Characteristics
Accuracy of operating time
Setting error
Reset time
Influence of voltage
Influence of temperature
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Ambient temperature
Ambient humidity
Life expectancy
Motor life expectancy
Approved standards
EMC (except for H2C-F@ models)
Case color
Degree of protection
Weight
±0.5% FS max. 〈±1% max. at 0.2 to 6 s for the time range code B or at 0.5 to 12 s for the time range
code C)
±2% FS max.
0.5 s max.
±1% FS max.
±2% FS max.
100 MΩ min. (at 500 VDC)
2,500 VAC, 50/60 Hz for 1 min (between current-carrying and non-current-carrying parts)
2,000 VAC, 50/60 Hz for 1 min (between contact and control circuit and between contacts of different
polarities)
1,000 VAC, 50/60 Hz for 1 min (between non-continuous contacts)
Destruction:
Malfunction:
Destruction:
Malfunction:
Operating:
Storage:
Operating:
Mechanical:
Electrical:
20,000 h
UL917, CSA C22.2 No.14.
Conforms to EN61812-1 and IEC60664-1 4 kV/1 (except for H2C-F@ models).
Output category according to EN60947-5-1 (except for H2C-F@ models).
(EMI)
Emission Enclosure:
Emission AC Mains:
(EMS)
Immunity ESD:
Immunity RF-interference from AM Radio Waves: IEC61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3)
Immunity Burst:
Immunity Surge:
Light gray (Munsell 5Y7/1)
IP40 (panel surface)
H2C series:
H2C-F series: approx. 270 g
1,000 m/s
150 m/s
–10°C to 50°C
–25°C to 65°C
10 to 55 Hz with 0.375-mm single amplitude for 1 h each in three directions
10 to 55 Hz with 0.25-mm single amplitude for 10 min each in three directions
45% to 85%
10,000,000 operations min. (under no load at 1,800 operations/h)
200,000 operations min. (3 A at 250 VAC, resistive load at 1,800 operations/h)
See Life-test Curve for other details.
approx. 180 g
2
2
EN61812-1
EN55011 Group 1 class A
EN55011 Group 1 class A
EN61812-1
IEC61000-4-2:
IEC61000-4-4:
IEC61000-4-5:
6 kV contact discharge (level 3)
1 kV line to line (level 3)
8 kV air discharge (level 3)
2 kV power-line (level 3)
2 kV I/O signal-line (level 4)
2 kV line to ground (level 3)
H2C
3