80PK-26 Fluke Electronics, 80PK-26 Datasheet

no-image

80PK-26

Manufacturer Part Number
80PK-26
Description
PROBE TAPERED TEMP SUREGRIP
Manufacturer
Fluke Electronics
Series
SureGrip™r
Type
K-Type Thermocoupler
Datasheets

Specifications of 80PK-26

Usage
HVAC
Tip - Type
Immersion / Penetration, Tapered
Plug Type
Sub-Mini (Thermocouple Plug)
Probe Temperature Range
-40 ~ 1500°F (-40 ~ 816°C)
Cable Length
39.370" (1000.00mm)
Cable Insulation
Poly-Vinyl Chloride (PVC)
Plug Color
Yellow
Probe Length
8.500" (215.90mm)
Probe Material
Stainless Steel
Lead Free Status / RoHS Status
Lead free by exemption / RoHS compliant by exemption
Other names
2098714
Introduction
The 80PK-26 SureGrip
essentially a bead probe with a handle that can be used
as a surface probe. The stainless steel sheath allows the
bead to measure temperatures higher than bead probes
with flexible leads. The handle also allows you to apply
more focused surface pressure without having your hand
in close proximity to the source. The 40-inch (1-meter)
cable is terminated with a Type K miniature thermocouple
connector with 0.792-mm (.312-in) pin spacing. The
80PK-26 can be used with any temperature-measuring
instrument that is designed to accept Type K
thermocouples and has miniature connector input.
Specifications
Type
K Standard Grade Ni-Cr vs Ni-Al (Chromel vs Alumel)
Measurement Range
Accuracy
(With respect to ANSI MC96.1-1982-Standard Limits of
Error):
November 2004
© 2004 Fluke Corporation. All rights reserved.
All product names are trademarks of their respective companies
-40 C to 816 C (-40 F to 1500 F)
-40 C to 0 C
(-40 F to 32 F)
0 C to 275 C
(32 F to 527 F)
275 C to 816 C
(527 F to 1500 F)
To avoid electrical shock, do not use this
probe when voltages exceeding 24 V ac rms
or 60 V dc are present. The probe tip is
electronically connected to the output
terminals.
All error calculations should be done in C, then
scaled to F.
Range
Temperature Probe
SureGrip
XWWarning
TM
Tapered Temperature Probe is
Note
±2.2 C
±1.1 C
±0.4 %
Instruction Sheet
80PK-26
(% of reading)
TM
Accuracy
Tapered
®

80PK-26 Summary of contents

Page 1

... The 40-inch (1-meter) cable is terminated with a Type K miniature thermocouple connector with 0.792-mm (.312-in) pin spacing. The 80PK-26 can be used with any temperature-measuring instrument that is designed to accept Type K thermocouples and has miniature connector input. Specifications ...

Page 2

Output @ 1.00 mV (reference junction @ 0 C) Seebeck Coefficient 40. Measurement Time (Time Constant): 3.0 seconds for air moving at 3.33 meters / second (10.9 ...

Page 3

... The stainless steel sheath should not be exposed to halides or sulfides. Even though the sheath to junction transition is sealed not recommended to immerse the probe in liquid or saturated vapor. The 80PK-26 should not be used in reducing atmospheres vacuum. Excess mounting force can deform or crush the bead. With the probe perpendicular to the measurement surface, do not apply more than 12 ...

Page 4

When measuring higher than ambient temperatures, adjust the connection between the probe and the surface until you get the highest temperature reading. To ensure a good connection, see the suggestions above. 3. When measuring lower than ambient temperatures, adjust ...

Page 5

... Figure 1. Fluke 80PK-26 Contacting Fluke For application or operation assistance, or information on Fluke products, call: USA: 1-888-44-FLUKE (1-888-443-5853) Canada: 1-800-36-FLUKE (1-800-363-5853) Europe: +31 402-675-200 Japan: +81-3-3434-0181 Singapore: +65-738-5655 Anywhere in the world: +1-425-446-5500 For USA Service: 1-888-99-FLUKE (1-888-993-5853) Or, visit Fluke's Web site at www.fluke.com. To register your product, visit register ...

Page 6

ONE YEAR LIMITED WARRANTY This Fluke product will be free from defects in material and workmanship for one year from the date of purchase. This warranty does not cover fuses, disposable batteries, or damage from accident, neglect, misuse, alteration, contamination, ...